Highly sensitive colorimetric detection of glucose and uric acid in biological fluids using chitosan-modified paper microfluidic devices

被引:161
作者
Gabriel, Ellen F. M. [1 ]
Garcia, Paulo T. [1 ]
Cardoso, Thiago M. G. [1 ]
Lopes, Flavio M. [2 ]
Martins, Felipe T. [1 ]
Coltro, Wendell K. T. [1 ]
机构
[1] Univ Fed Goias, Inst Quim, BR-74690900 Goiania, Go, Brazil
[2] Univ Fed Goias, Fac Farm, BR-74605170 Goiania, Go, Brazil
关键词
ELECTROCHEMISTRY; NANOPARTICLES; SMARTPHONE; PLATFORMS; SURFACE;
D O I
10.1039/c6an00430j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the modification of microfluidic paper-based analytical devices (mu PADs) with chitosan to improve the analytical performance of colorimetric measurements associated with enzymatic bioassays. Chitosan is a natural biopolymer extensively used to modify biosensing surfaces due to its capability of providing a suitable microenvironment for the direct electron transfer between an enzyme and a reactive surface. This hypothesis was investigated using glucose and uric acid (UA) colorimetric assays as model systems. The best colorimetric sensitivity for glucose and UA was achieved using a chromogenic solution composed of 4-aminoantipyrine and sodium 3,5-dichloro-2-hydroxy-benzenesulfonate (4-AAP/DHBS), which provided a linear response for a concentration range between 0.1 and 1.0 mM. Glucose and UA were successfully determined in artificial serum samples with accuracies between 87 and 114%. The limits of detection (LODs) found for glucose and UA assays were 23 and 37 mu M, respectively. The enhanced analytical performance of chitosan-modified mu PADs allowed the colorimetric detection of glucose in tear samples from four nondiabetic patients. The achieved concentration levels ranged from 130 to 380 mu M. The modified mu PADs offered analytical reliability and accuracy as well as no statistical difference from the values achieved through a reference method. Based on the presented results, the proposed mu PAD can be a powerful alternative tool for non-invasive glucose analysis.
引用
收藏
页码:4749 / 4756
页数:8
相关论文
共 59 条
[1]   Electrochemical paper-based microfluidic devices [J].
Adkins, Jaclyn ;
Boehle, Katherine ;
Henry, Charles .
ELECTROPHORESIS, 2015, 36 (16) :1811-1824
[2]   Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers [J].
Baca, Justin T. ;
Taormina, Christopher R. ;
Feingold, Eleanor ;
Finegold, David N. ;
Grabowski, Joseph J. ;
Asher, Sanford A. .
CLINICAL CHEMISTRY, 2007, 53 (07) :1370-1372
[3]   A glucose-sensing contact lens: from bench top to patient [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
CURRENT OPINION IN BIOTECHNOLOGY, 2005, 16 (01) :100-107
[4]   Fluorescence sensors for monosaccharides based on the 6-methylquinolinium nucleus and boronic acid moiety: potential application to ophthalmic diagnostics [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
TALANTA, 2005, 65 (03) :762-768
[5]   Preparation and properties evaluation of chitosan-coated cassava starch films [J].
Bangyekan, C ;
Aht-Ong, D ;
Srikulkit, K .
CARBOHYDRATE POLYMERS, 2006, 63 (01) :61-71
[6]   Recent Developments in Paper-Based Microfluidic Devices [J].
Cate, David M. ;
Adkins, Jaclyn A. ;
Mettakoonpitak, Jaruwan ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2015, 87 (01) :19-41
[7]   Simple, distance-based measurement for paper analytical devices [J].
Cate, David M. ;
Dungchai, Wijitar ;
Cunningham, Josephine C. ;
Volckens, John ;
Henry, Charles S. .
LAB ON A CHIP, 2013, 13 (12) :2397-2404
[8]   Evaluation of Commercial Glucometer Test Strips for Potential Measurement of Glucose in Tears [J].
Cha, Kyoung Ha ;
Jensen, Gary C. ;
Balijepalli, Anant S. ;
Cohan, Bruce E. ;
Meyerhoff, Mark E. .
ANALYTICAL CHEMISTRY, 2014, 86 (03) :1902-1908
[9]   Determination of glucose and uric acid with bienzyme colorimetry on microfluidic paper-based analysis devices [J].
Chen, Xi ;
Chen, Jin ;
Wang, Fubin ;
Xiang, Xia ;
Luo, Ming ;
Ji, Xinghu ;
He, Zhike .
BIOSENSORS & BIOELECTRONICS, 2012, 35 (01) :363-368
[10]   Paper-based Glucose Biosensing System Utilizing a Smartphone as a Signal Reader [J].
Chun, Hyeong Jin ;
Park, Yoo Min ;
Han, Yong Duk ;
Jang, Yo Han ;
Yoon, Hyun C. .
BIOCHIP JOURNAL, 2014, 8 (03) :218-226