An improved reversal technique from retrograde to antegrade femoral artery cannulation

被引:14
作者
Hartnell, G [1 ]
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
antegrade catheterization; transluminal angioplasty; arteries; femoral; interventional procedures;
D O I
10.1007/s002709900315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Converting retrograde femoral access to antegrade access may be required following diagnostic arteriography to perform an interventional procedure. This technical note describes a modification of a previously described technique that allows reliable catheter reversal which was successful in 27 attempted procedures. There were no complications.
引用
收藏
页码:512 / 513
页数:2
相关论文
共 5 条
[2]  
KADIR S, 1980, AJR, V136, P430
[3]   NEW DIRECTIONAL ACCORDION CATHETER FOR CONVERTING A RETROGRADE PUNCTURE INTO AN ANTEGRADE CATHETER PLACEMENT [J].
MILES, SG ;
SIRAGUSA, R ;
HAWKINS, IF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (01) :197-199
[4]   CATHETER FOR CONVERSION OF RETROGRADE TO ANTEGRADE FEMORAL-ARTERY CATHETERIZATION [J].
PATEL, YD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (01) :179-180