Experimental investigation and feasibility analysis on a capillary radiant heating system based on solar and air source heat pump dual heat source

被引:61
|
作者
Zhao, M. [1 ,2 ]
Gu, Z. L. [1 ]
Kang, W. B. [1 ,2 ]
Liu, X. [1 ]
Zhang, L. Y. [1 ]
Jin, L. W. [1 ]
Zhang, Q. L. [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[2] China Northwest Architecture Design & Res Inst Co, Xian 710018, Shaanxi, Peoples R China
[3] Beijing Univ Civil Engn & Architecture, Beijing Municipal Key Lab Heating Gas Supply Vent, Beijing 100084, Peoples R China
关键词
Solar energy; Energy saving; Radiant-capillary-terminal; Building heating; Thermal comfort; ENERGY-CONSUMPTION; CHINA; FLOOR; PERFORMANCE;
D O I
10.1016/j.apenergy.2016.02.043
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to sustainable development, solar energy has drawn much attention and been widely applied in buildings. However, the application of solar energy is limited because of its instability, intermittency and low energy density in winter. In order to use low density and instable solar energy source for heating and improve the utilization efficiency of solar energy, a solar phase change thermal storage (SPCTS) heating system using a radiant-capillary-terminal (RCT) to effectively match the low temperature hot water, a phase change thermal storage (PCTS) to store and continuously utilize the solar energy, and an air source heat pump (ASHP) as an alternate energy, was proposed and set up in this research. Series of experiments were conducted to obtain the relation between the solar radiation utilization rate and the heating supply temperatures, and to evaluate the performance of the RCT module and the indoor thermal environment of the system for its practical application in a residential building in the north-western City of Xi'an, China. The results show that energy saving of the solar heating system can be significantly improved by reducing the supplied water temperature, and the supplied water temperature of the RCT would be no more than 35 degrees C. The capillary radiation heating can adopt a lower water temperature and create a good thermal comfort environment as well. These results may lead to the development of designing and distributing the solar energy for building heating during winter. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2094 / 2105
页数:12
相关论文
共 50 条
  • [21] System investigation OFA solar combined with air-source heat pump system for greenhouse heating
    Sun, Xianpeng
    Guo, Kangquan
    Zou, Zhirong
    Zhang, Yue
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2016, 37 (03): : 658 - 665
  • [22] The Combined Solar with a Dual Heat Source Heat Pump Applied in a Greenhouse Heating System-an Operation Optimization of Water Source Heat Pump
    Sun, Xianpeng
    Zou, Zhirong
    Zhang, Yue
    ENGINEERING AND MANUFACTURING TECHNOLOGIES, 2014, 541-542 : 942 - +
  • [23] Investigation and Experiment of Coupling Heating Device Based on Solar Energy and Dual Source Heat Pump
    Wang, Boyuan
    He, Tao
    Zhang, Xinyu
    Wang, Conghui
    Deng, Yu
    Huang, Zhulian
    Zhang, Lei
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 449 - 457
  • [24] Experimental investigation on contacting heating system assisted by air source heat pump in residential buildings
    Luo, Xilian
    Li, Juan
    Zhu, Xiaoyu
    Wen, He
    Zhao, Min
    CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 935 - 940
  • [25] Experimental investigation on direct expansion solar-air source heat pump for water heating application
    Chinnasamy, Subramaniyan
    Arunachalam, Amarkarthik
    RENEWABLE ENERGY, 2023, 202 : 222 - 233
  • [26] Experimental Study on Operating Characteristic of the System of Ground Source Heat Pump Combined With Floor Radiant Heating of Capillary Tube
    Fu, Yunzhun
    Cai Yingling
    Li, Jing
    Wang, Yeyu
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 659 - 662
  • [27] Experimental and numerical investigation on the heating performance of a novel multi-functional heat pump system with solar-air composite heat source
    Cai, Jingyong
    Zhou, Haihua
    Xu, Lijie
    Zhang, Tao
    SUSTAINABLE CITIES AND SOCIETY, 2021, 73
  • [28] Thermodynamic and economic analysis of the air source heat pump system with direct-condensation radiant heating panel
    Shao, Suola
    Zhang, Huan
    Fan, Xianwang
    You, Shijun
    Wang, Yaran
    Wei, Shen
    ENERGY, 2021, 225
  • [29] Performance experiment on solar energy and air dual-heat-source heat pump system
    Hou L.
    Quan Z.
    Du B.
    Zhao Y.
    Jiang B.
    Quan, Zhenhua (quanzh@bjut.edu.cn), 1600, Materials China (71): : 5498 - 5505
  • [30] Experimental research on solar-ground source heat pump heating system
    Zhang, Wei
    Zhu, Jialing
    Hu, Tao
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2011, 32 (04): : 496 - 500