In situ exploring the dynamic behaviors of gas bubbles in liquid by using a tapered dual-hole hollow fiber

被引:0
|
作者
Long, Gang [1 ]
Wan, Hao [1 ]
Yang, Siyuan [1 ]
Wang, Ning [1 ]
Zhou, Ai [1 ]
Zhao, Kun [1 ]
Liao, Zhaolong [2 ]
Shui, Biao [2 ]
Li, Litong [2 ]
机构
[1] Wuhan Univ Technol, Natl Engn Res Ctr Fiber Opt Sensing Technol & Netw, Wuhan 430070, Peoples R China
[2] Yangtze Opt Fibre & Cable joint stock Ltd Co, State Key Lab Opt Fiber & Cable Manufacture Techno, Wuhan 430073, Peoples R China
关键词
Tapered dual -hole hollow fiber; Gas bubbles; Contact area; Coalescence; Effective refractive index; MACH-ZEHNDER INTERFEROMETER; OPTICAL-FIBER; TEMPERATURE; FLOTATION; WATER; SIZE; CELL;
D O I
10.1016/j.surfin.2022.102322
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Multiphase systems are often accompanied by highly complex gas-liquid-solid interactions and interface be-haviors, which are difficult to be captured directly. This work reports theoretically and experimentally the studies on monitoring the dynamic behaviors of the gas bubbles in liquid by using a tapered dual-hole optical fiber-based interferometer. As demonstrated by regulating their size, quantity, and arrangement, gas bubbles touching the waist region of the tapered fiber lead to a spectral response of the interferometer, and the total area of the gas-solid interface between them directly determines the wavelength shift of the output spectrum. Beyond that, the sensor with the uniform tapered waist region (length: 1.5 cm, diameter: CYRILLIC CAPITAL LETTER EF 5 mu m) is fabricated to explore the gas bubbles' coalescence. In this case, the gas bubbles contact each other until the waist region of tapered fiber is radially enclosed entirely. When the enclosed gas-solid interface area varies between 16,000 -24,000 mu m2, the wavelength shift responds exponentially to the area, and the sensitivity at the area of 16,000 mu m2 is calculated to be 2.42 pm/mu m2. The proposed sensing platform could be adapted to in situ and online explore the multiphase dynamics for applications such as cell analysis, energy production, and environmental monitoring.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Dual-Pass Hollow-Core Fiber Gas Spectroscopy Using a Reflective Configuration With Heterodyne-Based Signal Detection
    Gomolka, Grzegorz
    Pysz, Dariusz
    Buczynski, Ryszard
    Nikodem, Michal
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2023, 41 (18) : 6094 - 6101
  • [32] Modeling of dual-skin asymmetric hollow fiber microporous membranes for predicting the skins parameters separately using gas permeation test
    Hashemifard, S. A.
    Matsuura, T.
    Alihemati, Z.
    JOURNAL OF MEMBRANE SCIENCE, 2024, 701
  • [33] Surface Modified Polysulfone Hollow Fiber Membranes for Ethane/Ethylene Separation Using Gas-Liquid Membrane Contactors with Ionic Liquid-Based Absorbent
    Kostyanaya, Margarita
    Bazhenov, Stepan
    Borisov, Ilya
    Plisko, Tatiana
    Vasilevsky, Vladimir
    FIBERS, 2019, 7 (01)
  • [34] Investigation of H2S and CO2 Removal from Gas Streams Using Hollow Fiber Membrane Gas-liquid Contactors
    Mirfendereski, M.
    Mohammadi, T.
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2017, 31 (02) : 139 - 144
  • [35] Miniaturized hollow fiber assisted liquid-phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for analysis of bisphenol A in human urine sample
    Kawaguchi, Migaku
    Ito, Rie
    Okanouchi, Noriya
    Saito, Koichi
    Nakazawa, Hiroyuki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 870 (01): : 98 - 102
  • [36] Determination of antidepressants in whole blood using hollow-fiber liquid-phase microextraction and gas chromatography-mass spectrometry
    dos Santos, Marcelo Filonzi
    Ferri, Caio Caleiras
    Seulin, Saskia Carolina
    Leyton, Vilma
    Goncalves Pasqualucci, Carlos Augusto
    Munoz, Daniel Romero
    Yonamine, Mauricio
    FORENSIC TOXICOLOGY, 2014, 32 (02) : 214 - 224
  • [37] 3D in-situ simulation and particle tracing of gas filtration process for ultrafine particles removal using a hollow fiber membrane
    Lin, Frank
    Chen, Pei-Chuan
    Huang, Tse-Chiang
    Lin, Geng-Sheng
    Tung, Kuo-Lun
    JOURNAL OF MEMBRANE SCIENCE, 2021, 632
  • [38] Surface modification of polypropylene hollow fiber membranes using fluorosilane for CO2 absorption in a gas-liquid membrane contactor
    Kim, Kwanghwi
    Lee, Heejun
    Park, Hyun Sic
    Song, Hojun
    Kim, Suhan
    HELIYON, 2023, 9 (09)
  • [39] Analysis of narcotic drugs in biological samples using hollow fiber liquid-phase microextraction and gas chromatography with nitrogen phosphorus detection
    Saraji, Mohammad
    Boroujeni, Maliheh Khalili
    MICROCHIMICA ACTA, 2011, 174 (1-2) : 159 - 166
  • [40] Determination of haloethers in water with dynamic hollow fiber liquid-phase microextraction using GC-FID and GC-ECD
    Chiang, Jing-Shan
    Huang, Shang-Da
    TALANTA, 2007, 71 (02) : 882 - 886