In situ exploring the dynamic behaviors of gas bubbles in liquid by using a tapered dual-hole hollow fiber

被引:0
|
作者
Long, Gang [1 ]
Wan, Hao [1 ]
Yang, Siyuan [1 ]
Wang, Ning [1 ]
Zhou, Ai [1 ]
Zhao, Kun [1 ]
Liao, Zhaolong [2 ]
Shui, Biao [2 ]
Li, Litong [2 ]
机构
[1] Wuhan Univ Technol, Natl Engn Res Ctr Fiber Opt Sensing Technol & Netw, Wuhan 430070, Peoples R China
[2] Yangtze Opt Fibre & Cable joint stock Ltd Co, State Key Lab Opt Fiber & Cable Manufacture Techno, Wuhan 430073, Peoples R China
关键词
Tapered dual -hole hollow fiber; Gas bubbles; Contact area; Coalescence; Effective refractive index; MACH-ZEHNDER INTERFEROMETER; OPTICAL-FIBER; TEMPERATURE; FLOTATION; WATER; SIZE; CELL;
D O I
10.1016/j.surfin.2022.102322
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Multiphase systems are often accompanied by highly complex gas-liquid-solid interactions and interface be-haviors, which are difficult to be captured directly. This work reports theoretically and experimentally the studies on monitoring the dynamic behaviors of the gas bubbles in liquid by using a tapered dual-hole optical fiber-based interferometer. As demonstrated by regulating their size, quantity, and arrangement, gas bubbles touching the waist region of the tapered fiber lead to a spectral response of the interferometer, and the total area of the gas-solid interface between them directly determines the wavelength shift of the output spectrum. Beyond that, the sensor with the uniform tapered waist region (length: 1.5 cm, diameter: CYRILLIC CAPITAL LETTER EF 5 mu m) is fabricated to explore the gas bubbles' coalescence. In this case, the gas bubbles contact each other until the waist region of tapered fiber is radially enclosed entirely. When the enclosed gas-solid interface area varies between 16,000 -24,000 mu m2, the wavelength shift responds exponentially to the area, and the sensitivity at the area of 16,000 mu m2 is calculated to be 2.42 pm/mu m2. The proposed sensing platform could be adapted to in situ and online explore the multiphase dynamics for applications such as cell analysis, energy production, and environmental monitoring.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Optimized design of an ultrasensitive tapered dual-hole fiber gas pressure sensor operating near the dispersion turning point
    Wang, Xinyu
    Ling, Qiang
    Luo, Si
    Tao, Jihong
    Cai, Mingda
    Yu, Zhangwei
    Chen, Daru
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2022, 39 (09) : 2415 - 2420
  • [2] Birefringence characterization in a dual-hole microstructured optical fiber using an OFDR method
    Meng, Xin
    Luo, Mingming
    Liu, Jianfei
    Zhao, Shuai
    Zhou, Ran
    APPLIED OPTICS, 2024, 63 (03) : 772 - 776
  • [3] Thulium Fiber Laser Induced Vapor Bubbles using Bare, Tapered, Ball, Hollow Steel, and Muzzle Brake Fiber Tips
    Gonzalez, David A.
    Hardy, Luke A.
    Hutchens, Thomas C.
    Irby, Pierce B.
    Fried, Nathaniel M.
    THERAPEUTICS AND DIAGNOSTICS IN UROLOGY 2018, 2018, 10468
  • [4] Dual fluorescent hollow silica nanofibers for in situ pH monitoring using an optical fiber
    Zhou, Junhu
    Ren, Yundong
    Nie, Yuan
    Jin, Congran
    Park, Jiyoon
    Zhang, John X. J.
    NANOSCALE ADVANCES, 2023, 5 (08): : 2180 - 2189
  • [5] Contaminant removal from natural gas using dual hollow fiber membrane contactors
    Cai, Jing Jing
    Hawboldt, Kelly
    Abdi, Majid Abedinzadegan
    JOURNAL OF MEMBRANE SCIENCE, 2012, 397 : 9 - 16
  • [6] High Sensitivity Temperature Sensor Based on Directional Coupler in a Liquid-Filled Tapered Hollow Suspended Dual-Core Fiber
    Li, Xixin
    Gao, Shan
    Yang, Jing
    Ye, Peng
    Zhu, Zheng
    Li, Ping
    Shi, Jinhui
    Yuan, Libo
    Guan, Chunying
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2024, 42 (14) : 5048 - 5054
  • [7] Determination of polychlorinated biphenyls in water using dynamic hollow fiber liquid-phase microextraction and gas chromatography-mass spectrometry
    Li, Guanhua
    Zhang, Lijun
    Zhang, Zhanen
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1204 (01) : 119 - 122
  • [8] REMOVAL OF CARBON-DIOXIDE FROM GAS STREAMS USING A GAS-LIQUID HOLLOW-FIBER MODULE
    ALSAFFAR, HB
    OKLANY, JS
    OZTURK, B
    HUGHES, R
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 1995, 73 (B2) : 144 - 150
  • [9] Removal of benzene from nitrogen by using polypropylene hollow fiber gas-liquid membrane contactor
    Xu, Jun
    Li, Rui
    Wang, Lianjun
    Li, Jiansheng
    Sun, Xiuyun
    SEPARATION AND PURIFICATION TECHNOLOGY, 2009, 68 (01) : 75 - 82
  • [10] In Situ All-Fiber Remote Gas Sensing Strategy Based on Anti-Resonant Hollow-Core Fiber and Middle-Hole Eccentric-Core Fiber
    Geng, Yuhan
    Zhang, Tie
    Wu, Shengnan
    He, Sailing
    PHOTONICS, 2024, 11 (04)