Optimization and validation of simultaneous analyses of ecgonine, cocaine, and seven metabolites in human urine by gas chromatography-mass spectrometry using a one-step solid-phase extraction

被引:7
作者
Fernandez, Nicolas [1 ]
Marina Cabanillas, Laura [1 ]
Monica Olivera, Nancy [1 ]
Noemi Quiroga, Patricia [1 ]
机构
[1] Univ Buenos Aires, Lab Asesoramiento Toxicol Analit CENATOXA, Catedra Toxicol & Quim Legal, Fac Farm & Bioquim, Junin 956 7mo Piso C1113AAD, Buenos Aires, DF, Argentina
关键词
cocaine and metabolites; ecgonine; GC-MS; one-step SPE; urine; RAPID ANALYSIS; WHOLE-BLOOD; BENZOYLECGONINE; MICROEXTRACTION; COCAETHYLENE; STABILITY; EXCRETION; PRODUCTS; OPIATES; SAMPLES;
D O I
10.1002/dta.2547
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The presence of ecgonine in urine has been proposed as an appropriate marker of cocaine use. Only a few methods have been published for their determination along with cocaine and the rest of its metabolites. Due to their high polarity and consequent solubility in water, these have low recoveries, which is why it is necessary to increase the sensitivity, by the formation of hydrochloric salts or multiderivatization of the analytes or by performing two solid-phase extractions (SPEs), considerably increasing the time and cost of the analysis. This work describes a fast and fully validated procedure for the simultaneous detection and quantification of ecgonine, ecgonine-methyl-ester, benzoylecgonine, nor-benzoylecgonine, m-hydroxybenzoylecgonine, cocaethylene, cocaine, norcocaine, and norcocaethylene in human urine (500 mu L) using one SPE and simple derivatization. Separation and quantification were achieved by gas chromatography-electron ionization-mass spectrometry (GC-EI-MS) in selected-ion monitoring mode. Quantification was performed by the addition of deuterated analogs as internal standards. Calibration curves were linear in the adopted ranges, with determination coefficients higher than 0.99. The lower limits of quantification ranged from 2.5 to 10 ng/mL. The intra- and inter-day precision, calculated in terms of relative standard deviation, were 1.2%-14.9% and 1.8%-17.9%, respectively. The accuracy, in terms of relative error, was within a +/- 16.4% interval. Extraction efficiency ranged from 84% to 103%. Compared with existing methods, the procedure described herein is fast, since only one SPE is required, and cost-effective. In addition, this method provides a high recovery for ecgonine, resulting in a better alternative to the previously published methods.
引用
收藏
页码:361 / 373
页数:13
相关论文
共 39 条
[1]   DETERMINATION OF COCAINE AND BENZOYLECGONINE BY DERIVATIZATION WITH IODOMETHANE-D(3) OR PFPA/HFIP IN HUMAN BLOOD AND URINE USING GC/MS (EI OR PCI MODE) [J].
ADERJAN, RE ;
SCHMITT, G ;
WU, M ;
MEYER, C .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (01) :51-55
[2]   Determination of cocaine and its major metabolite benzoylecgonine in several matrices obtained from deceased individuals with presumed drug consumption prior to death [J].
Alvear, Eduardo ;
von Baer, Dietrich ;
Mardones, Claudia ;
Hitschfeld, Antonieta .
JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2014, 23 :37-43
[4]  
[Anonymous], 2001, GUID IND BIOAN METH
[5]  
[Anonymous], 1996, GUID IND Q2B VAL AN
[6]  
[Anonymous], FED REG
[7]  
[Anonymous], 2015, European Guidelines for Workplace Drug Testing in Urine
[8]  
[Anonymous], 2009, Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens
[9]   STABILITY OF COCAINE IN BIOLOGICAL-FLUIDS [J].
BASELT, RC .
JOURNAL OF CHROMATOGRAPHY, 1983, 268 (03) :502-505
[10]   Simultaneous analyses of cocaine, cocaethylene, and their possible metabolic and pyrolytic products [J].
Cardona, PS ;
Chaturvedi, AK ;
Soper, JW ;
Canfield, DV .
FORENSIC SCIENCE INTERNATIONAL, 2006, 157 (01) :46-56