Thermodynamic potential of a high-concentration hybrid photovoltaic/thermal plant for co-production of steam and electricity

被引:28
|
作者
Sarafraz, M. M. [1 ,2 ]
Goodarzi, Marjan [3 ]
Tlili, Iskander [4 ]
Alkanhal, Tawfeeq Abdullah [5 ]
Arjomandi, Maziar [6 ]
机构
[1] Univ Adelaide, Sch Chem Engn & Adv Mat, Adelaide, SA, Australia
[2] Univ Warwick, Sch Engn, Coventry CV4 7AL, W Midlands, England
[3] Duy Tan Univ, Inst Res & Dev, Da Nang 550000, Vietnam
[4] Majmaah Univ, Coll Engn, Dept Mech & Ind Engn, Al Majmaah 11952, Saudi Arabia
[5] Majmaah Univ, Coll Engn, Dept Mechatron & Syst Engn, Al Majmaah 11952, Saudi Arabia
[6] Univ Adelaide, Sch Mech Engn, Adelaide, SA, Australia
关键词
Concentrated photovoltaic; Nano-suspension; hybrid thermal systems; electricity production; Solar steam production; Dual hybrid receiver; PERFORMANCE EVALUATION; PV; DESIGN; NANOFLUIDS; SYSTEMS; PANELS;
D O I
10.1007/s10973-020-09914-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
A thermodynamic model was developed to assess the energetic performance of a dual receiver concentrated photovoltaic/thermal plant for the co-production of steam, electricity and hot water/air. The system utilizes a dual receiver including a steam generator based on a solar receiver and a concentrated PV/thermal receiver. The system is regulated so that a fraction (phi) of the thermal energy absorbed by the solar field is partitioned for the steam generator, while the rest is dedicated to the CPV/T unit. The results showed that the thermal performance of the system strongly depends on the phi value such that the system can simultaneously produce electricity and steam, while warm air and water can also be produced by cooling the CPV/T unit. Also, the thermal performance of the coolant is a key element to the system, which highlights the potential of nano-suspensions as a coolant in the system. Likewise, the assessment of the process plant was performed at field area of 2500-10,000 m(2), the solar concentration ratio of 50-200 and the CPV/T coolant's outlet temperature of 323-353 K. It was found that the highest values of thermal losses can be similar to 2% of the total thermal input of the plant. Also, a trade-off trend was identified between the phi value, steam and electricity production. It was also found that at a solar concentration ratio of 2000, the system is competitive to produce steam to be fed into a multi-flash desalination system. The energetic performance of the system revealed that at phi = 0.75, about 48% of the energy is partitioned for the hot water and hot air production for the agricultural application, while 24% is used for the electricity and 26% is used for the steam production.
引用
收藏
页码:1389 / 1398
页数:10
相关论文
共 50 条
  • [41] Performance of a direct steam generation solar thermal power plant for electricity production as a function of the solar multiple
    Montes, M. J.
    Abanades, A.
    Martinez-Val, J. M.
    SOLAR ENERGY, 2009, 83 (05) : 679 - 689
  • [42] Review of high concentration photovoltaic thermal hybrid systems for highly efficient energy cogeneration
    Cameron, William James
    Reddy, K. Srinivas
    Mallick, Tapas Kumar
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 163
  • [43] An analysis of the thermodynamic cycles with high-temperature nuclear reactor for power generation and hydrogen co-production
    Dudek, Michal
    Jaszczur, Marek
    ENERGY AND FUELS 2016, 2017, 14
  • [44] Thermodynamic potential of a novel plasma-assisted sustainable process for co-production of ammonia and hydrogen with liquid metals
    Sarafraz, M. M.
    Tran, N. N.
    Pourali, N.
    Rebrov, E. V.
    Hessel, V.
    ENERGY CONVERSION AND MANAGEMENT, 2020, 210 (210)
  • [45] Steam explosion of lignocellulosic residues for co-production of value-added chemicals and high-quality pellets
    Tanase-Opedal, Mihaela
    Ghoreishi, Solmaz
    Hermundsgard, Dag Helge
    Barth, Tanja
    Moe, Storker T.
    Brusletto, Rune
    BIOMASS & BIOENERGY, 2024, 181
  • [46] Thermodynamic analysis and optimal design of an innovative CaC2 and electricity co-production system through air separation and energy storage
    Liu, Qingshan
    Chen, Hui
    Liu, Yingwen
    Arabkoohsar, Ahmad
    Hu, Lulu
    Xue, Xiaodai
    RENEWABLE ENERGY, 2024, 237
  • [47] CO2 capture by carbide slag calcined under high-concentration steam and energy requirement in calcium looping conditions
    Zhang, Wan
    Li, Yingjie
    He, Zirui
    Ma, Xiaotong
    Song, Haiping
    APPLIED ENERGY, 2017, 206 : 869 - 878
  • [48] Exergoeconomic analysis of high concentration photovoltaic thermal co-generation system for space cooling
    Garcia-Heller, Veronica
    Paredes, Stephan
    Ong, Chin Lee
    Ruch, Patrick
    Michel, Bruno
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 34 : 8 - 19
  • [49] Study on the Removal of High-concentration Chloride Ion from Desulfurization Wastewater in Thermal Power Plant by Removing Chlorine Extractant
    Wang Yiwen
    Liu Ning
    Yuan Zhaowei
    Wang Anqi
    2018 FIRST INTERNATIONAL CONFERENCE ON ENVIRONMENT PREVENTION AND POLLUTION CONTROL TECHNOLOGY (EPPCT 2018), 2018, 199
  • [50] Experimental Research about High-Concentration Polymer Flooding in 6th Oil Production Plant of Daqing Oilfield
    Fan, Wenjie
    Su, Yanchang
    Li, Yiqiang
    ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 762 - +