Simple and Rapid LC-MS/MS Method for Determination of Perampanel in Human Plasma and Application to Bioequivalence Study

被引:2
|
作者
Gao, Pan [1 ]
Zou, Qiao-gen [1 ]
机构
[1] Nanjing Technol Univ, Dept Biotechnol & Pharmaceut Sci, Nanjing 210009, Peoples R China
关键词
Perampanel; LC-MS; MS; human plasma; bioequivalence study; protein precipitation; pharmacokinetic; AMPA RECEPTOR ANTAGONIST; ANTIEPILEPTIC DRUGS; HPLC; EPILEPSY; ASSAY;
D O I
10.2174/1573412918666220609203438
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Perampanel (PER) is a third-generation antiepileptic drug (AED). Several methods have been developed for the quantification of perampanel in plasma. The pharmacokinetic characteristics of perampanel in healthy Chinese ubjects have not been comprehensively reported. Objective: A simple, fast and sensitive LC-MS/MS method was established and validated for the quantification of perampanel in human plasma and its application to a bioequivalence study. Methods: Chromatographic separation was accomplished on a ZORBAX Eclipse XDB-Phenyl column (4.6 mm x 75 mm, 3.5 mu m) using a binary gradient with mobile phase (A) (water containing 5 mmol/L ammonium acetate and 0.1% formic acid and (B) acetonitrile-water (95:5, v/v) at a flow rate of 0.9 mL/min and sample preparation was by one-step protein precipitation via acetonitrile. Results: The total run time in this study was 4.5 min and the retention time of perampanel and perampanel-d5 (internal standard) were 2.30 min and 2.32 min, respectively. The method was developed and validated over the concentration range of 2.00-500 ng/mL for perampanel, with a correlation coefficient greater than 0.9992. The inter-day precision was 3.1%-3.8% and accuracy was 98.9%-103.5%. The intra-day precision was 2.4%-6.8% and the accuracy was 97.6%-104.9%. The extraction recovery ranged from 99.23%-103.84% and the matrix effect was not significant. Perampanel was proved to be stable in solution and human plasma under different tested conditions. The validated method was successfully applied to a randomized, open-label, 2-period, crossover bioequivalence study in healthy Chinese subjects, and the results indicated that bioequivalence was achieved for 2 formulations of the 4-mg perampanel tablet under both fasting and fed conditions, and both treatments were safe and well-tolerated by all study subjects. Conclusion: The validated method was successfully applied to a bioequivalence study of perampanel in human plasma and has achieved satisfactory results.
引用
收藏
页码:919 / 929
页数:11
相关论文
共 50 条
  • [1] Simple and rapid LC-MS/MS method for determination of sitagliptin in human plasma and application to bioequivalence study
    Loh, Gabriel Onn Kit
    Wong, Emily Yii Ling
    Tan, Yvonne Tze Fung
    Lee, Yi Lin
    Pang, Lai Hui
    Chin, May Chien
    Damenthi, Nair
    Peh, Kok Khiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [2] A simple and sensitive LC-MS/MS method for determination of doxylamine in human plasma and its application in a bioequivalence study in healthy Chinese volunteers
    Fu, Rong
    Sheng, Mang
    Yang, Can
    Liu, Luyao
    Xiong, Wenqiang
    Wang, Xing
    Chen, Xiaodan
    Yu, Zhongjian
    Gao, Yuan
    Tan, Hong
    Xin, Chenlu
    Zhang, Hong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 220
  • [3] LC-MS/MS Analytical Method for Determination of Montelukast in Human Plasma and its Application to a Bioequivalence Study
    Said, Rana
    CURRENT PHARMACEUTICAL ANALYSIS, 2023, 19 (02) : 163 - 175
  • [4] Determination of terbinafine in healthy Chinese human plasma using a simple and fast LC-MS/MS method and its application to a bioequivalence study
    Yang, Can
    Liu, Luyao
    Sheng, Mang
    Fu, Rong
    Chen, Xiaodan
    Yu, Zhongjian
    Gao, Yuan
    Zhang, Hong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1191
  • [5] Determination of amoxicillin in human plasma by LC-MS/MS and its application to a bioequivalence study
    Pingale, Satish G.
    Badgujar, Madhukara
    Mangaonkar, Kiran V.
    Mastorakis, Nikos E.
    PROCEEDINGS OF THE WORLD MEDICAL CONFERENCE, 2010, : 86 - +
  • [6] Determination of lacidipine in human plasma by LC-MS/MS: Application in a bioequivalence study
    Chen, Hao
    Li, Lan
    Song, Shuai
    Du, Yan
    Jin, Xiaoqin
    Ding, PeiPei
    Shen, Chenlin
    Huang, Xiaohui
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2018, 56 (10) : 493 - 500
  • [7] Development and application of a novel LC-MS/MS method for human plasma concentration monitoring of perampanel in pediatric epilepsy patients
    Zhao, Ting
    Yu, Lu-Hai
    Zhang, Hui-Lan
    Yu, Jing
    Feng, Jie
    Li, Hong-Jian
    Sun, Yan
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (10)
  • [8] Development and Validation of a Rapid and Sensitive LC-MS/MS Method for the Determination of Aripiprazole in Human Plasma: Application to a Bioequivalence Study
    Patel, D. S.
    Sharma, N.
    Patel, M. C.
    Patel, B. N.
    Shrivastav, P. S.
    Sanyal, M.
    ACTA CHROMATOGRAPHICA, 2014, 26 (02) : 203 - 227
  • [9] Simple and fast LC-MS/MS method for quantification of terazosin in human plasma and application to bioequivalence study
    Loh, Gabriel Onn Kit
    Wong, Emily Yii Ling
    Tan, Yvonne Tze Fung
    Ong, Loke Meng
    Ng, Ru Shing
    Wee, Hong Chin
    Peh, Kok Khiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1163
  • [10] Simple and rapid LC-MS/MS method for determination of Piribedil in human plasma
    Alshishani, Anas
    Hasan, Inas
    Ghanayem, Fatima
    Al-khasawneh, Sewar
    Abu Dayah, Alaa
    PHARMACIA, 2022, 69 (03) : 615 - 620