The Application of Distributed Partial Discharge Synchronous Detection with Wireless Communication on HV Cable Withstand Voltage Test

被引:0
|
作者
Chen, Min [1 ]
Zhou, Zhipeng [2 ]
Pan, Daren [2 ]
Su, Tianyu [2 ]
Cai, Shitin [2 ]
Lu, Jingjing [3 ]
机构
[1] SF Technol Ltd, Hong Kong, Peoples R China
[2] ZF Technol Ltd, Guangzhou, Peoples R China
[3] SE Technol Ltd, Hong Kong, Peoples R China
关键词
cable; withstand voltage test; PD; distribution; wireless communication; synchronization;
D O I
10.1109/EIC49891.2021.9612263
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) synchronous detection is an effective means to improve the quality of the handover test when the withstand voltage test is carried out on the high-voltage cable line, because it is easier to find the hidden defects when the voltage is higher than the operating voltage. However, PD detection of cable lines requires that PD sensors and signal processing devices must be installed at each cable junction or termination. The detection signals distributed in each joint of the cable must be transmitted and collected to the central processing unit for centralized analysis and display. For those several kilometers to more than ten kilometers of buried cable line, if there is no pre-wired communication network, the only way to rely on wireless communication. Due to the complex conditions of the test site, the speed and the stability of the wireless communication network are difficult to guarantee the data transmission of more than 3M bytes/s required by PD measurement. A new distributed PD detection system with wireless communication has been successfully developed and used in recent voltage tests of several 110 kV and 220 kV cable lines. A hybrid wireless communication system was used at the trial site, utilizing 4G/5G communication between the local distributed signal processors and Wi-Fi communication between the central signal processing unit. This communication method can not only meet the data needs of PRPD and PRPS graphs for displaying PD detection signals distributed in the whole line synchronously, but also realize the display of point-to-point signal waveform, and ensure the trend observation effect of each distributed signal and the synchronous comparison function of multi-point signal actograms. This paper attempts to briefly describe the composition and technical parameters of the PD detection system, the form of field application and the system method through a 110kV cable circuit withstand voltage test case.
引用
收藏
页码:694 / 698
页数:5
相关论文
共 39 条
  • [1] Application of Distributed Partial Discharge Detection Technique Synchronized with AC Withstand Voltage Test of High Voltage Cable
    Zhang Tian-ting
    Zhou Gui-ping
    Wang Shun-jiang
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [2] Partial discharge in High Voltage Equipments-HV Cable
    James, Jasmin
    Kulkarni, S. V.
    Parekh, B. R.
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 445 - +
  • [3] Oscillating Lightning Impulse Voltage Withstand Test and Partial Discharge Detection Technology for Power Transformers
    Zhang X.
    Wang H.
    Hu Y.
    Zhou Y.
    Li J.
    Han X.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (12): : 5032 - 5041
  • [4] Comparison of on-line partial discharge detection methods for HV cable joints
    Tian, Y
    Lewin, PL
    Davies, AE
    Swingler, SG
    Sutton, SJ
    Hathaway, GM
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (04) : 604 - 615
  • [5] Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in HV Equipment
    Upton, D. W.
    Saeed, B. I.
    Khan, U.
    Jaber, A.
    Mohamed, H.
    Mistry, K.
    Mather, P. J.
    Lazaridis, P.
    Vieira, M. F. Q.
    Atkinson, R.
    Tachtatzis, C.
    Iorkyase, E.
    Judd, M.
    Glover, I. A.
    2017 XXXIIND GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM OF THE INTERNATIONAL UNION OF RADIO SCIENCE (URSI GASS), 2017,
  • [6] Development of a partial discharge detection algorithm and verification test for extra-high-voltage cable system
    Choi, Won
    Kim, Jeong-Tae
    Seo, In-Jin
    Hwang, Jae-Sang
    Koo, Ja-Yoon
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (02) : 111 - 119
  • [7] Research and practice on the BPD frequency conversion power used in partial discharge and voltage withstand test
    Yichang Power Supply Company, Yichang 443003, China
    Gaoya Dianqi, 2007, 2 (146-148):
  • [8] Detection and localization of partial discharge in high voltage power cable joints
    Kheirmand, A
    Leijon, M
    Tornkvist, C
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 145 - 148
  • [9] Development of Partial Discharge Detection Device for PD Detection on Medium Voltage XLPE Cable
    Radzi, M. I. F. Mohamad
    Ahmad, M. R.
    Ali, N. H. Nik
    Ariffin, A. Mohd
    2020 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), 2021,
  • [10] Distributed Detection and Acoustic Emission Waveform Retrieval of Cable Joint Partial Discharge
    Qin, Wei-qi
    Ma, Guo-ming
    Hu, Jing
    Guo, Tengjun
    Wang, Sihan
    Liu, Hao
    Wang, Yuan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2977 - 2980