Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers

被引:20
|
作者
Bechstedt, Maren [1 ]
Gustafson, Jonathan A. [2 ]
Mell, Steven P. [2 ]
Guehrs, Julian [1 ]
Morlock, Michael M. [1 ]
Levine, Brett R. [2 ]
Lundberg, Hannah J. [2 ]
机构
[1] TUHH Hamburg Univ Technol, Inst Biomech, D-21073 Hamburg, Germany
[2] Rush Univ, Dept Orthoped Surg, Med Ctr, 1611 W Harrison St Suite 201, Chicago, IL 60612 USA
关键词
Total hip arthroplasty; Modularity; Surface topography; Finite element analysis; Contact mechanics; FINITE-ELEMENT; FRETTING WEAR; MORSE TAPER; MECHANICAL RESPONSE; REALISTIC FORCES; INTERFACE; STRENGTH; REPLACEMENTS; PREDICTION; IMPLANTS;
D O I
10.1016/j.jbiomech.2020.109689
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Implant failure due to fretting-corrosion of head-neck modular junctions is a rising problem in total hip arthroplasty. Fretting-corrosion initiates when micromotion leads to metal release; however, factors leading to micromotion, such as microgrooves on the stem taper, are not fully understood. The purpose of this study is to describe a finite element analysis technique to determine head-neck contact mechanics and investigate the effect of stem taper microgroove height during head-neck assembly. Two-dimensional axisymmetric finite element models were created. Models were created for a ceramic femoral head and a CoCrMo femoral head against Ti6AI4V stem tapers and compared to available data from prior experiments. Stem taper microgroove height was investigated with a generic 12/14 model. Head-neck assembly was performed to four maximum loads (500 N, 2000 N, 4000 N, 8000 N). For the stem taper coupled with the ceramic head, the number of microgrooves in contact and plastically deformed differed by 2.5 microgrooves (4%) and 6.5 microgrooves (11%), respectively, between the finite element models and experiment. For the stem taper coupled with the CoCrMo head, all microgrooves were in contact after all assembly loads in the finite element model due to an almost identical conical angle between the taper surfaces. In the experiments, all grooves were only in contact for the 8000 N assembly load. Contact area, plastic (permanent) deformation, and contact pressure increased with increasing assembly loads and deeper microgrooves. The described modeling technique can be used to investigate the relationship between implant design factors, allowing for optimal microgroove design within material couples. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] In Vivo Damage of the Head-Neck Junction in Hard-on-Hard Total Hip Replacements: Effect of Femoral Head Size, Metal Combination, and 12/14 Taper Design
    Baleani, Massimiliano
    Erani, Paolo
    Bordini, Barbara
    Zuccheri, Federica
    Makosa, Mateusz Kordian
    De Pasquale, Dalila
    Beraudi, Alina
    Stea, Susanna
    MATERIALS, 2017, 10 (07):
  • [32] The mechanics of head-neck taper junctions: What do we know from finite element analysis?
    Feyzi, Mohsen
    Fallahnezhad, Khosro
    Taylor, Mark
    Hashemi, Reza
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 116
  • [33] Influence of the taper on the fretting wear of the femoral stem-femoral head taper junction in total hip prosthesis
    Capitanu, Lucian
    Badita, Liliana-Laura
    Tiganesteanu, Constantin
    Florescu, Virgil
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2022, 74 (04) : 385 - 391
  • [34] Iliopsoas Irritation as Presentation of Head-Neck Corrosion After Total Hip Arthroplasty: A Case Series
    Ko, Laura Matsen
    Coleman, Jacob J.
    Stas, Venessa
    Duwelius, Paul J.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (04) : 461 - +
  • [35] Evidence based recommendations for reducing head-neck taper connection fretting corrosion in hip replacement prostheses
    Wight, Christian M.
    Lanting, Brent
    Schemitsch, Emil H.
    HIP INTERNATIONAL, 2017, 27 (06) : 523 - 531
  • [36] Determination of local micromotion at the stem-neck taper junction of a bi-modular total hip prosthesis design
    Falkenberg, Adrian
    Drummen, Paul
    Morlock, Michael M.
    Huber, Gerd
    MEDICAL ENGINEERING & PHYSICS, 2019, 65 : 31 - 38
  • [37] Head Taper Corrosion Causing Head Bottoming Out and Consecutive Gross Stem Taper Failure in Total Hip Arthroplasty
    Morlock, Michael M.
    Dickinson, Emilie C.
    Guenther, Klaus-Peter
    Buente, Dennis
    Polster, Valerie
    JOURNAL OF ARTHROPLASTY, 2018, 33 (11): : 3581 - 3590
  • [38] Effect of Femoral Head Material, Surgeon Experience, and Assembly Technique on Simulated Head-Neck Total Hip Arthroplasty Impaction Forces
    Godoy, Michael
    Sipek, Kirsten
    Gustafson, Jonathan A.
    Yuh, Catherine
    Levine, Brett R.
    Pourzal, Robin
    Lundberg, Hannah J.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (02): : 507 - 513.e1
  • [39] Radiographic Risk Factors Associated With Adverse Local Tissue Reaction in Head-Neck Taper Corrosion of Primary Metal-on-Polyethylene Total Hip Arthroplasty
    Kwon, Young-Min
    An, Shuai
    Yeo, Ingwon
    Tirumala, Venkatsaiakhil
    Chen, Wenhao
    Klemt, Christian
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (08) : 353 - 360
  • [40] Fixation strength of taper connection at head-neck junction in retrieved carbon fiber-reinforced PEEK hip stems
    Nakahara, Ichiro
    Takao, Masaki
    Bandoh, Shunichi
    Sugano, Nobuhiko
    JOURNAL OF ARTIFICIAL ORGANS, 2014, 17 (04) : 358 - 363