The use of miniaturized chromatographic systems is an important strategy for reducing the consumption of supplies related to separations, allowing the development of more sustainable analytical methodologies. However, the high cost and complexity in the production of these systems combined with the operational difficulties and the need for the use of solvent and sample pretreatment are challenges to be overcome in order to make the chromatographic methods greener. Here, we report the construction and development of a low cost microfluidic system for green and solvent-free chromatographic separations with electro-chemical detection integrated into cotton threads without the use of any mechanical pumping to transport the solutions. The manufacture of the proposed system was performed by simple assembly of the components, with the separation of the species based on an ion exchange mechanism and detection using gold electrodes manufactured directly on the cotton threads. A linear range of 0.025-5.0 mM was obtained for the effective separation of ascorbic acid (AA) and dopamine (DA) with detection limits of 2.89 mu M (for AA) and 4.41 mu M (for DA). Each analysis was performed at a low cost (less than 0.01 dollars), and with a small volume of waste generated (107.1 mu L). So, the proposed system was successfully employed to determine the levels of AA and DA present in the tears of healthy volunteers without sample pretreatment, indicating the good analytical performance of the system and the possibility of performing greener chromatographic separations.
引用
收藏
页码:670 / 678
页数:9
相关论文
共 51 条
[1]   Raman spectroscopic investigation of acetylation of raw cotton [J].
Adebajo, MO ;
Frost, RL ;
Kloprogge, JT ;
Kokot, S .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2006, 64 (02) :448-453
[2]   Green chromatography for the analysis of foods of animal origin [J].
Armenta, Sergio ;
de la Guardia, Miguel .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 80 :517-530
[3]   Microfluidic electrocapture for separation of peptides [J].
Astorga-Wells, J ;
Vollmer, S ;
Tryggvason, S ;
Bergman, T ;
Jörnvall, H .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7131-7136
[4]   Current applications of miniaturized chromatographic and electrophoretic techniques in drug analysis [J].
Aturki, Zeineb ;
Rocco, Anna ;
Rocchi, Silvia ;
Fanali, Salvatore .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 101 :194-220
[5]   Patterned paper and alternative materials as substrates for low-cost microfluidic diagnostics [J].
Ballerini, David R. ;
Li, Xu ;
Shen, Wei .
MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (05) :769-787
[6]   Chemical synthesis and sensing in inexpensive thread-based microdevices [J].
Banerjee, Shashwat S. ;
Roychowdhury, Abhijit ;
Taneja, Neetika ;
Janrao, Ravindra ;
Khandare, Jayant ;
Paul, Debjani .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 :439-445
[7]   Thread-based microfluidics: Flow patterns in homogeneous and heterogeneous microfiber bundles [J].
Berthier, J. ;
Brakke, K. A. ;
Gosselin, D. ;
Berthier, E. ;
Navarro, F. .
MEDICAL ENGINEERING & PHYSICS, 2017, 48 :55-61
[8]   Liquid chromatographic methods for the quantification of catecholamines and their metabolites in several biological samples-A review [J].
Bicker, Joana ;
Fortuna, Ana ;
Alves, Gilberto ;
Falcao, Amilcar .
ANALYTICA CHIMICA ACTA, 2013, 768 :12-34
[9]   Powering electronic contact lenses: current achievements, challenges, and perspectives [J].
Blum, Zoltan ;
Pankratov, Dmitry ;
Shleev, Sergey .
EXPERT REVIEW OF OPHTHALMOLOGY, 2014, 9 (04) :269-273
[10]   Gold nanoparticles supported on multi-walled carbon nanotubes produced by biphasic modified method and dopamine sensing application [J].
Caetano, Fabio R. ;
Felippe, Leticia B. ;
Zarbin, Aldo J. G. ;
Bergamini, Marcio F. ;
Marcolino-Junior, Luiz H. .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 :43-50