The performance of an evacuated tube solar hot water system in a domestic house throughout a year in a northern maritime climate (Dublin)

被引:20
作者
Gill, Laurence [1 ]
Mac Mahon, Joanne [1 ]
Ryan, Kevin [1 ]
机构
[1] Univ Dublin, Dept Civil Struct & Environm Engn, Trinity Coll, Dublin, Ireland
关键词
Evacuated tube; Solar water heater; Domestic hot water; THERMAL PERFORMANCE; FLAT-PLATE; TEMPERATE CLIMATE; HEATING SYSTEM; COLLECTORS; ENERGY; HEATERS; CONSUMPTION; RESOLUTION;
D O I
10.1016/j.solener.2016.07.052
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The performance of an evacuated tube solar hot water system, installed on a domestic house (occupied by 2 adults and 3 children) in Dublin, Ireland has been intensely monitored over the period of a year. Instrumentation to measure flows and temperature were installed throughout both the solar circuit and domestic hot water system, in addition to solar radiometers being installed, on site to measure both global and diffuse radiation. The overall annual solar system efficiency at the installation angle of 29 to the horizontal was 63%. Heat losses from all aspects of the solar circuit and hot water system have also been quantified. The ongoing hot water usage pattern of the house occupants over the course of the year has been analysed as well as the changing attitudes to the use of hot water since the installation of the new solar system. This has shown some evidence that more hot water tends to be used on days where there has been more direct sunlight. Net present value calculations based on 5 years of operation however, have shown that the retrofit of such a system is not currently economically viable, although it has produced a carbon saving of approximately 1.1 tonnes CO2eq over its first 5 years of operation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:261 / 272
页数:12
相关论文
共 43 条
[21]   Long-term performances prediction of an evacuated tube solar water heating system used for single-family households under typical Nord-African climate (Tunisia) [J].
Hazami, Majdi ;
Kooli, Sami ;
Naili, Nabiha ;
Farhat, Abdelhamid .
SOLAR ENERGY, 2013, 94 :283-298
[22]  
IEA, 2016, COMP THERM EN STOR M
[23]  
IEA, 2002, DEV DIR CHAR TEST PR
[24]  
IEA, 2016, TECHN DEM TECHN SUBT
[25]  
ISO, 2013, 98062013 ISO
[26]  
Jakhrani A., 2013, WORLD APPL SCI J, V22, P1334, DOI [DOI 10.5829/idosi.wasj.2013.22.09.316, 10.5829/idosi.wasj.2013.22.09.316]
[27]   Influence of the DHW load profile on the fractional energy savings: A case study of a solar combi-system with TRNSYS simulations [J].
Jordan, U ;
Vajen, K .
SOLAR ENERGY, 2000, 69 (1-6) :197-208
[28]   Performance of solar systems employing collectors with colored absorber [J].
Kalogirou, S ;
Tripanagnostopoulos, Y ;
Souliotis, M .
ENERGY AND BUILDINGS, 2005, 37 (08) :824-835
[29]   Solar thermal collectors and applications [J].
Kalogirou, SA .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2004, 30 (03) :231-295