The performance of an evacuated tube solar hot water system in a domestic house throughout a year in a northern maritime climate (Dublin)

被引:20
|
作者
Gill, Laurence [1 ]
Mac Mahon, Joanne [1 ]
Ryan, Kevin [1 ]
机构
[1] Univ Dublin, Dept Civil Struct & Environm Engn, Trinity Coll, Dublin, Ireland
关键词
Evacuated tube; Solar water heater; Domestic hot water; THERMAL PERFORMANCE; FLAT-PLATE; TEMPERATE CLIMATE; HEATING SYSTEM; COLLECTORS; ENERGY; HEATERS; CONSUMPTION; RESOLUTION;
D O I
10.1016/j.solener.2016.07.052
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The performance of an evacuated tube solar hot water system, installed on a domestic house (occupied by 2 adults and 3 children) in Dublin, Ireland has been intensely monitored over the period of a year. Instrumentation to measure flows and temperature were installed throughout both the solar circuit and domestic hot water system, in addition to solar radiometers being installed, on site to measure both global and diffuse radiation. The overall annual solar system efficiency at the installation angle of 29 to the horizontal was 63%. Heat losses from all aspects of the solar circuit and hot water system have also been quantified. The ongoing hot water usage pattern of the house occupants over the course of the year has been analysed as well as the changing attitudes to the use of hot water since the installation of the new solar system. This has shown some evidence that more hot water tends to be used on days where there has been more direct sunlight. Net present value calculations based on 5 years of operation however, have shown that the retrofit of such a system is not currently economically viable, although it has produced a carbon saving of approximately 1.1 tonnes CO2eq over its first 5 years of operation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:261 / 272
页数:12
相关论文
共 29 条
  • [1] Performance evaluation of evacuated tube solar domestic hot water systems in Hong Kong
    Chow, Tin-Tai
    Dong, Zhaoting
    Chan, Lok-Shun
    Fong, Kwong-Fai
    Bai, Yu
    ENERGY AND BUILDINGS, 2011, 43 (12) : 3467 - 3474
  • [2] Profitability Variations of a Solar System with an Evacuated Tube Collector According to Schedules and Frequency of Hot Water Demand
    Porras-Prieto, Carlos J.
    Benedicto-Schonemann, Susana
    Mazarron, Fernando R.
    Benavente, Rosa M.
    ENERGIES, 2016, 9 (12):
  • [3] Effect of PCM application inside an evacuated tube collector on the thermal performance of a domestic hot water system
    Felinski, Piotr
    Sekret, Robert
    ENERGY AND BUILDINGS, 2017, 152 : 558 - 567
  • [4] Thermosyphon heat-pipe evacuated tube solar water heaters for northern maritime climates
    Redpath, David A. G.
    SOLAR ENERGY, 2012, 86 (02) : 705 - 715
  • [5] Performance Evaluation of an Evacuated Flat-Plate Collector System for Domestic Hot Water Applications
    Saeed, Hamza
    Mahmood, Mariam
    Nazir, Hassan
    Waqas, Adeel
    Ahmad, Naveed
    Ali, Majid
    Haseeb, Abdul
    Sajid, Muhammad Bilal
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (05):
  • [6] Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions
    Maraj, Altin
    Londo, Andonaq
    Gebremedhin, Alemayehu
    Firat, Coskun
    RENEWABLE ENERGY, 2019, 140 : 874 - 883
  • [7] Thermal performance of an evacuated tube heat pipe solar water heating system in cold season
    Shafieian, Abdellah
    Khiadani, Mehdi
    Nosrati, Ataollah
    APPLIED THERMAL ENGINEERING, 2019, 149 : 644 - 657
  • [8] Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate
    Ayompe, L. M.
    Duffy, A.
    Mc Keever, M.
    Conlon, M.
    McCormack, S. J.
    ENERGY, 2011, 36 (05) : 3370 - 3378
  • [9] On the Performance Assessment of Using Alcohol/Water Mixtures in a Solar Rankine Cycle System with an Evacuated Tube Collector
    Hsu, Pu-Yin
    Sun, Chen-li
    INTERNATIONAL CONFERENCE ON THERMAL SCIENCE AND TECHNOLOGY (ICTST) 2017, 2018, 1984
  • [10] Experimental investigation on enhancement of thermal performance with obstacle placing in the horizontal hot water tank used in solar domestic hot water system
    Erdemir, Dogan
    Atesoglu, Hakan
    Altuntop, Necdet
    RENEWABLE ENERGY, 2019, 138 : 187 - 197