Poorer color discrimination by females when tested with pseudoisochromatic plates containing vanishing designs on neutral backgrounds

被引:8
作者
Baraas, Rigmor C. [1 ]
机构
[1] Buskerud Univ Coll, Dept Optometry & Visual Sci, N-3603 Kongsberg, Norway
关键词
color vision; pseudoisochromatic tests; color-vision testing; heterozygote; children;
D O I
10.1017/S0952523808080632
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
It might be expected that normal trichromatic females would perform as well as normal trichromatic males of the same age when tested with standard clinical color-vision tests that use pseudoisochromatic vanishing designs on neutral gray backgrounds Such as the Hardy-Rand-Rittler (HRR) pseudoisochromatic plates and the Neitz Test of Color Vision (NTCV). Here 2966 children aged 6-13 years from four Municipalities in Norway were tested in their school classrooms with the NTCV. Children who made errors on the test were retested. 187 males and 152 females made one or more errors oil retest. and each was tested individually on the Richmond HRR Fourth Edition. 8% of the males were defined as color deficient when a double criterion for failing was applied, that is, one or more errors on the NTCV and two or more errors on the HRR. The calculated frequency of color-deficient females (homozygotes) for the same criterion is 0.42%. By contrast, 3% of females failed the criterion that gave a stable population of color-deficient males. This result is considered in relation to reports of female carriers of color-vision deficiency having problems with the Ishihara test and of females having poorer color discrimination than males.
引用
收藏
页码:501 / 505
页数:5
相关论文
共 36 条
[1]   MOLECULAR DETERMINANTS OF HUMAN RED/GREEN COLOR DISCRIMINATION [J].
ASENJO, AB ;
RIM, J ;
OPRIAN, DD .
NEURON, 1994, 12 (05) :1131-1138
[2]   Evaluation of an updated HRR color vision test [J].
Bailey, JE ;
Neitz, M ;
Tait, DM ;
Neitz, J .
VISUAL NEUROSCIENCE, 2004, 21 (03) :431-436
[3]  
BELCHER S J, 1958, Br J Ophthalmol, V42, P355, DOI 10.1136/bjo.42.6.355
[4]   Clinical use of the American Optical Company (Hardy, Rand and Rittler) pseudoisochromatic plates for red-green colour deficiency [J].
Birch, J .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1997, 17 (03) :248-254
[5]   The new Richmond HRR pseudoisochromatic test for colour vision is better than the Ishihara test [J].
Cole, Barry L. ;
Lian, Ka-Yee ;
Lakkis, Carol .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2006, 89 (02) :73-80
[8]   Colorimetric analysis of four editions of the Hardy-Rand-Rittler pseudoisochromatic tests [J].
Dain, SJ .
VISUAL NEUROSCIENCE, 2004, 21 (03) :437-443
[9]   INCIDENCE OF UNILATERAL AND BILATERAL COLOR-BLINDNESS IN HETEROZYGOUS FEMALES [J].
FEIG, K ;
ROPERS, HH .
HUMAN GENETICS, 1978, 41 (03) :313-323
[10]   H-R-R POLYCHROMATIC PLATES [J].
HARDY, LH ;
RAND, G ;
RITTLER, MC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1954, 44 (07) :509-523