Energy-Saving Potential of Building Envelope Designs in Residential Houses in Taiwan

被引:50
作者
Lai, Chi-Ming [1 ,2 ]
Wang, Yao-Hong [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Civil Engn, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Res Ctr Energy Technol & Strategy, Tainan 701, Taiwan
关键词
energy; building; thermal performance; THERMAL COMFORT; SIMULATION;
D O I
10.3390/en4112061
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The key factors in the energy-saving design of a building's exterior in Taiwan are the thermal performance of the roof and window glazing. This study used the eQUEST software to investigate how different types of roof construction, window glasses and sunshield types affect the energy consumption in residential buildings under common scenarios. The simulation results showed that the use of an appropriate window glass significantly reduced the annual energy consumption, followed by the shading device, whereas the roof construction produced less of an energy-efficiency benefit. By using a low-E glass and a 1.5 x 1.5 m box shading (e.g., balcony), this could save approximately 15.1 and 13.6% of the annual electricity consumption of air conditioners, respectively. Therefore, having control over the dominant factors in the building envelope is indeed an important step in the path to achieving energy savings and carbon reduction in residential houses.
引用
收藏
页码:2061 / 2076
页数:16
相关论文
共 19 条
[1]  
Aixing H, 2002, NEW BUILDING MAT, V3, P25
[2]  
Alcazar S., 2005, ENERGY PERFORMANCE G
[3]  
[Anonymous], HOME DOE 2 BASED BUI
[4]  
Bush D.V., 2002, Energy engineering, V99, P71
[5]   Green roofs; building energy savings and the potential for retrofit [J].
Castleton, H. F. ;
Stovin, V. ;
Beck, S. B. M. ;
Davison, J. B. .
ENERGY AND BUILDINGS, 2010, 42 (10) :1582-1591
[6]   A technical review of energy conservation programs for commercial and government buildings in Thailand [J].
Chirarattananon, S ;
Taweekun, J .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (05) :743-762
[7]  
Kuo B.Y., 2005, THESIS NATL CHENG KU
[8]   Integration of distributed generation systems into generic types of commercial buildings in California [J].
Medrano, M. ;
Brouwer, J. ;
McDonell, V. ;
Mauzey, J. ;
Samuelsen, S. .
ENERGY AND BUILDINGS, 2008, 40 (04) :537-548
[9]   Analysis of the green roof thermal properties and investigation of its energy performance [J].
Niachou, A ;
Papakonstantinou, K ;
Santamouris, M ;
Tsangrassoulis, A ;
Mihalakakou, G .
ENERGY AND BUILDINGS, 2001, 33 (07) :719-729
[10]  
Qinghai L., 2005, GAS HEAT, V25, P72