Comparison of near-infrared methods for pharmaceutical product drying:: In situ vs. effluent sampling

被引:3
|
作者
Steck, E [1 ]
Tarczynski, F [1 ]
Walker, DS [1 ]
机构
[1] GlaxoSmithKline Inc, Res Triangle Pk, NC 27709 USA
关键词
drying; near infrared; diffuse reflectance; effluent comparison;
D O I
10.1366/0003702011953045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Previous studies showed how the end point of drying can be determined by using on-line near-infrared (NIR) spectroscopy. These methods either place a probe directly into the dryer in contact with the material being dried or monitor the evolved vapor stream as the drying process proceeds. This report demonstrates the comparability of these methods in detecting the end point of the drying process by measuring both values simultaneously during the drying of a pharmaceutical product.
引用
收藏
页码:1109 / 1111
页数:3
相关论文
共 50 条
  • [31] COMPARISON OF MULTIVARIATE CALIBRATION METHODS FOR PREDICTION OF FEEDING VALUE BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    GOEDHART, PW
    NETHERLANDS JOURNAL OF AGRICULTURAL SCIENCE, 1990, 38 (03): : 449 - 460
  • [32] A COMPARISON OF METHODS FOR MOISTURE DETERMINATION OF FORAGES FOR NEAR-INFRARED REFLECTANCE SPECTROSCOPY CALIBRATION AND VALIDATION
    WINDHAM, WR
    ROBERTSON, JA
    LEFFLER, RG
    CROP SCIENCE, 1987, 27 (04) : 777 - 783
  • [33] A COMPARISON OF MICROBIAL, ENZYMATIC, CHEMICAL AND NEAR-INFRARED REFLECTANCE SPECTROSCOPY METHODS IN FORAGE EVALUATION
    COELHO, M
    HEMBRY, FG
    BARTON, FE
    SAXTON, AM
    ANIMAL FEED SCIENCE AND TECHNOLOGY, 1988, 20 (03) : 219 - 231
  • [34] MOISTURE ANALYSIS OF FORAGE BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY - PRELIMINARY COLLABORATIVE STUDY AND COMPARISON BETWEEN FISCHER,KARL AND OVEN DRYING REFERENCE METHODS
    WINDHAM, WR
    BARTON, FE
    ROBERTSON, JA
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1988, 71 (02): : 256 - 262
  • [35] Effect of data preprocessing methods in near-infrared diffuse reflectance spectroscopy for the determination of the active compound in a pharmaceutical preparation
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    delaPezuela, C
    APPLIED SPECTROSCOPY, 1997, 51 (02) : 240 - 246
  • [36] Near-infrared spectroscopy-based methods for quantitative determination of active pharmaceutical ingredient in transdermal gel formulations
    Szabo, Eva
    Gergely, Szilveszter
    Spaits, Tamas
    Simon, Tunas
    Salgo, Andras
    SPECTROSCOPY LETTERS, 2019, 52 (10) : 599 - 611
  • [37] Enhanced Written vs. Verbal Recall Accuracy Associated With Greater Prefrontal Activation: A Near-Infrared Spectroscopy Study
    Zhang, Jianan
    Wang, Ya
    Zhang, Yu
    Li, Brian
    Zhang, Yi
    FRONTIERS IN BEHAVIORAL NEUROSCIENCE, 2021, 15
  • [38] Pellet Coating Thickness Determination by Near-Infrared Reflectance Spectroscopy: Comparison of Two Reference Methods
    Muselik, Jan
    Dvorackova, Katerina
    Krejcova, Katerina
    Rabiskova, Miloslava
    Pazourek, Jiri
    Marton, Sylvia
    Drackova, Michaela
    Vorlova, Lenka
    CURRENT PHARMACEUTICAL ANALYSIS, 2010, 6 (04) : 225 - 233
  • [39] COMPARISON OF NEAR-INFRARED SPECTROSCOPY CALIBRATION METHODS FOR THE PREDICTION OF PROTEIN, OIL, AND STARCH IN MAIZE GRAIN
    ORMAN, BA
    SCHUMANN, RA
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (05) : 883 - 886
  • [40] Monitoring complex media fermentations with near-infrared spectroscopy: Comparison of different variable selection methods
    Ferreira, AP
    Alves, TP
    Menezes, JC
    BIOTECHNOLOGY AND BIOENGINEERING, 2005, 91 (04) : 474 - 481