Treatment of mandible fractures using low-profile titanium miniplates: Preliminary study

被引:9
作者
Kim, YK [1 ]
Nam, KW [1 ]
机构
[1] Pundang Jesaeng Hosp, Daejin Med Ctr, Dept Oral & Maxillofacial Surg, Pundang Gu, Seong Nam City 463050, Kyung Gi Do, South Korea
关键词
D O I
10.1097/00006534-200107000-00007
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study evaluated the short-term results of patients treated with low-profile titanium miniplates for fractures of the mandible. Thirty-one fractures of the mandible in 23 patients were treated by open reduction and internal fixation using thin, low-profile miniplates and 1.3-mm self-threading screws. Duration of intermaxillary fixation ranged from 0 to 25 days. Patients were evaluated for complications during a followup period ranging from 6 to 24 months. Seven patients (30.4 percent) experienced complications. These included infection (n = 1), premature occlusal contact (n = 1),wound dehiscence (n = 1), temporomandibular joint disorder (n = 1), and paresthesia (n = 3). All complications were minor and adequately managed with incision and drainage, medication, and elastic traction. Low-profile titanium miniplates can be adequately used for internal fixation in selective mandibular fractures. Advantages of these types of plates include comfort due to the thinness of miniplates and ease of application.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 18 条
[1]   EXPERIENCE WITH RIGID FIXATION OF MANDIBULAR FRACTURES AND IMMEDIATE FUNCTION [J].
ANDERSON, T ;
ALPERT, B .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (06) :555-560
[2]   EXPERIMENTAL LONG-TERM STUDY OF TITANIUM IONS ELUTED FROM PURE TITANIUM MINIPLATES [J].
BESSHO, K ;
FUJIMURA, K ;
IIZUKA, T .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (07) :901-904
[3]   Clinical and animal experiments on stress corrosion of titanium miniplates [J].
Bessho, K. ;
Iizuka, K.B.T. .
Clinical Materials, 1993, 14 (03) :223-227
[4]   TREATMENT OF MANDIBULAR ANGLE FRACTURES USING 2 2.4-MM DYNAMIC COMPRESSION PLATES [J].
ELLIS, E ;
SINN, DP .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (09) :969-973
[5]   TREATMENT OF MANDIBULAR ANGLE FRACTURES USING 2 MINI DYNAMIC COMPRESSION PLATES [J].
ELLIS, E ;
KARAS, N .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (09) :958-963
[6]   Treatment of mandibular angle fractures using one noncompression miniplate [J].
Ellis, E ;
Walker, LR .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (07) :864-871
[7]   TREATMENT OF MANDIBULAR ANGLE FRACTURES USING THE AO RECONSTRUCTION PLATE [J].
ELLIS, E .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (03) :250-254
[8]   Tissue response to titanium plates: A transmitted electron microscopic study [J].
Kim, YK ;
Yeo, HH ;
Lim, SC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1997, 55 (04) :322-326
[9]  
KIM YK, 1994, J KOREA ACAD MAXILLO, V46, P438
[10]   RIGID INTERNAL-FIXATION FOR THE TREATMENT OF INFECTED MANDIBULAR FRACTURES [J].
KOURY, M ;
ELLIS, E .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (05) :434-443