Comparison between GC-TCD and GC-FID for the determination of propane in gas mixture

被引:15
作者
Budiman, Harry [1 ]
Nuryatini [1 ]
Zuas, Oman [1 ]
机构
[1] Kawasan PUSPIPTEK, Indonesian Inst Sci LIPI, Res Ctr Chem, Gas Anal Lab GasAL, Serpong 15314, Banten, Indonesia
来源
INTERNATIONAL SYMPOSIUM ON APPLIED CHEMISTRY 2015 | 2015年 / 16卷
关键词
propane; gas chromatography; thermal conductivity detector (TCD); flame ionization detector (FID); QUALITY; TRENDS;
D O I
10.1016/j.proche.2015.12.080
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method comparison between gas chromatography-thermal conductivity detector (GC-TCD) and chromatography-flame ionization detector (GC-FID) for the analysis of propane (C3H8) are reported in this study. To achieve the study purpose for producing valid and reliable result, the method comparison process was conducted by investigating several keys of analytical parameter of both GC-TCD and GC-FID method including method sensitivity, precision, accuracy, and method linearity. Investigation of the GC's parameter were conducted by analyzing the C3H8 (% mol/mol) in nitrogen (N-2) balance (known as C3H8 certified reference material). The results show that the GC-FID method was found to display more sensitive, precise, and accurate than GC-TCD method for the analysis of C3H8. The sensitivity of the GC-FID are 66 times higher than GC-TCD method. In addition, the GC-FID exhibits a wider linear range (0.161-2.18 %mol/mol) than the GC-TCD method (0.242 - 2.18 %mol/mol). (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:465 / 472
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 2004, MODERN PRACTICE GAS, DOI DOI 10.1002/0471651141
[2]  
[Anonymous], 2007, MEET ISO 17025 REQ M
[3]  
[Anonymous], ISO GUID 33 US CERT
[4]   Thermal conductivity of gas by pulse injection techniques using specific thermal conductivity detector (TCD) [J].
Cataluña, R ;
da Silva, R ;
Menezes, EW ;
Samios, D .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2004, 15 (06) :839-843
[5]   Gas chromatography analysis: method validation and measurement uncertainty evaluation for volume fraction measurements of gases in simulated reformate gas stream [J].
Drolc, Andreja ;
Djinovic, Petar ;
Pintar, Albin .
ACCREDITATION AND QUALITY ASSURANCE, 2013, 18 (03) :225-233
[6]  
Hibbert D.B., 2006, Data Analysis for Chemistry
[7]  
HILBORN J C, 1975, Science of the Total Environment, V4, P97, DOI 10.1016/0048-9697(75)90017-0
[8]  
Kaiser H.J., 2006, J VALID TECHNOL, V10, P15
[9]  
Liptak BG, 2003, INSTR ENG HDB, V1
[10]  
Magnusson B., 2014, FITNESS PURPOSE ANAL