Sensitive Electrochemical Detection of Phosphorylated-Tau Threonine 231 in Human Serum Using Interdigitated Wave-Shaped Electrode

被引:9
|
作者
Le, Hien T. Ngoc [1 ]
Cho, Sungbo [1 ,2 ]
机构
[1] Gachon Univ, Dept Elect Engn, Seongnam Si 13120, South Korea
[2] Gachon Univ, Gachon Adv Inst Hlth Sci & Technol GAIHST, Dept Hlth Sci & Technol, Incheon 21999, South Korea
基金
新加坡国家研究基金会;
关键词
phosphorylated-tau threonine 231; Alzheimer's disease; electrochemical biosensor; micro-interdigitated electrode; electrochemical impedance spectroscopy; binding affinity; LABEL-FREE; SUPRAMOLECULAR RECOGNITION; PROTEIN; BIOSENSOR; DISEASE; SENSOR; GOLD;
D O I
10.3390/biomedicines10010010
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The development of an electrochemical biosensor for the detection of phosphorylated-tau threonine 231 (p-tau231), a biomarker of Alzheimer's disease (AD), has yet to be achieved. Therefore, in this study, we developed a simple, small size, cheap, and sensitive electrochemical biosensor based on an interdigitated wave-shaped electrode via an activated self-assembled monolayer to preserve a specific anti-p-tau231 antibody (IWE/SAM/EDC-NHS/anti-p-tau231). Detection of p-tau231 in human serum (HS) using the biosensor was undertaken using electrochemical impedance spectroscopy (EIS). The change in charge-transfer resistance (R-ct) in the EIS analysis of the biosensor indicated the detection of p-tau231 in HS within a wide linear range of detection (10(-4)-10(1) ng mL(-1)), and a low limit of detection (140 pg mL(-1)). This lower limit is less than the detection level of p-tau231 in cerebrospinal fluid (CSF) (700 pg mL(-1)) of AD patients and the level of CSF p-tau231 of patients with mild cognitive impairment (501 pg mL(-1)), demonstrating the possibility of using the biosensor in detection of p-tau231 at early stage AD. A high binding affinity and low dissociation constant (K-d) between anti-p-tau231 and p-tau231 in HS was demonstrated by using a biosensor and K-d was 7.6 pM, demonstrating the high specific detection of p-tau231 by the biosensor. The good selectivity of the biosensor for the detection of p-tau231 with differential analytes was also examined in this study.
引用
收藏
页数:11
相关论文
共 11 条
  • [1] Sensitive electrochemical detection of amyloid beta peptide in human serum using an interdigitated chain-shaped electrode
    Le, Hien T. Ngoc
    Park, Jinsoo
    Chinnadayyala, Somasekhar R.
    Cho, Sungbo
    BIOSENSORS & BIOELECTRONICS, 2019, 144
  • [2] Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
    Chinnadayyala, Somasekhar R.
    Park, Jinsoo
    Kim, Young Hyo
    Choi, Seong Hye
    Lee, Sang-Myung
    Cho, Won Woo
    Lee, Ga-Yeon
    Pyun, Jae-Chul
    Cho, Sungbo
    SENSORS, 2019, 19 (24)
  • [3] Detection of the tau protein in human serum by a sensitive four-electrode electrochemical biosensor
    Wang, Scarlet Xiaoyan
    Acha, Desiree
    Shah, Ajit J.
    Hills, Frank
    Roitt, Ivan
    Demosthenous, Andreas
    Bayford, Richard H.
    BIOSENSORS & BIOELECTRONICS, 2017, 92 : 482 - 488
  • [4] A Probeless Capacitive Biosensor for Direct Detection of Amyloid Beta 1-42 in Human Serum Based on an Interdigitated Chain-Shaped Electrode
    Le, Hien T. Ngoc
    Park, Jinsoo
    Cho, Sungbo
    MICROMACHINES, 2020, 11 (09)
  • [5] Rapid and Ultrasensitive Detection of Staphylococcus aureus Using a Gold-Interdigitated Single-Wave-Shaped Electrode (Au-ISWE) Electrochemical Biosensor
    My-Van Tieu
    Duc Trung Pham
    Hien T. Ngoc Le
    Thi Xoan Hoang
    Sungbo Cho
    BioChip Journal, 2023, 17 : 507 - 516
  • [6] Rapid and Ultrasensitive Detection of Staphylococcus aureus Using a Gold-Interdigitated Single-Wave-Shaped Electrode (Au-ISWE) Electrochemical Biosensor
    Tieu, My-Van
    Pham, Duc Trung
    Le, Hien T. Ngoc
    Hoang, Thi Xoan
    Cho, Sungbo
    BIOCHIP JOURNAL, 2023, 17 (04) : 507 - 516
  • [7] Sensitive and Simultaneous Detection of Cardiac Markers in Human Serum Using Surface Acoustic Wave Immunosensor
    Lee, Joonhyung
    Choi, Youn-Suk
    Lee, Yeolho
    Lee, Hun Joo
    Lee, Jung Nam
    Kim, Sang Kyu
    Han, Kyung Yeon
    Cho, Eun Chol
    Park, Jae Chan
    Lee, Soo Suk
    ANALYTICAL CHEMISTRY, 2011, 83 (22) : 8629 - 8635
  • [8] Diagnosis of viral infectious diseases through sensitive detection of human serum antibodies using a modified label-free electrochemical biosensor
    Andrade, Tatianny de Araujo
    Ribeiro, Iare Soares
    Silva, Tiago Almeida
    de Souza, Leyllanne Katharinne Araujo
    Coltro, Wendell Karlos Tomazelli
    Borges, Lysandro Pinto
    Silva, Deise Maria Rego Rodrigues
    Garcia, Paulo de Tarso
    de Jesus, Jemmyson Romario
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (28) : 6345 - 6355
  • [9] Cortisol Detection in Undiluted Human Serum Using a Sensitive Electrochemical Structure-Switching Aptamer over an Antifouling Nanocomposite Layer
    Singh, Naveen K.
    Chung, Saeromi
    Sveiven, Michael
    Hall, Drew A.
    ACS OMEGA, 2021, 6 (42): : 27888 - 27897
  • [10] A highly sensitive electrochemical biosensor for chlorpyrifos pesticide detection using the adsorbent nanomatrix contain the human serum albumin and the Pd:CdTe quantum dots
    Ehzari, Hosna
    Safari, Meysam
    Samimi, Mohsen
    Shamsipur, Mojtaba
    Gholivand, Mohammad Bagher
    MICROCHEMICAL JOURNAL, 2022, 179