Drug metabolism biosensors:: electrochemical reactivities of cytochrome P450cam immobilised in synthetic vesicular systems

被引:50
作者
Iwuoha, EI [1 ]
Joseph, S
Zhang, Z
Smyth, MR
Fuhr, U
de Montellano, PRO
机构
[1] Dublin City Univ, Sch Chem Sci, Biomed & Environm Sensor Technol Ctr, Dublin 9, Ireland
[2] Univ Koeln, Inst Pharmacol, Koeln, Germany
[3] Univ Calif San Francisco, Sch Pharm, San Francisco, CA 94143 USA
关键词
amperometric biosensor; cytochrome p450(cam); electrochemistry; enzyme electrode; drug metabolism biosensor; liquid crystal film; amperometry; cyclic voltammetry;
D O I
10.1016/S0731-7085(98)00076-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors containing cytochrome P450(cam) in a didodecyldimethylammonium bromide vesicular system were prepared by cross-linking onto a glassy carbon electrode (GCE) with glutaraldehyde in the presence of bovine serum albumin. Cyclic voltammetric responses of the sensor in air-free buffer solution showed that the sensor exhibited reversible electrochemistry due to direct electron exchange between the haem Fe3+/(2+) redox system and the GCE surface. In air-saturated solution containing camphor, the biosensor gave an irreversible electrocatalytic current which is compatible with the monooxygenation of the substrate. Steady state amperometric experiments with camphor, adamantanone and fenchone were performed with a biosensor prepared by cross-linking P450(cam) with glutaraldehyde onto a Pt disc electrode. The sensor was characterised by fast amperometric responses, attaining steady-state in about 20 s in a cobalt sepulchrate mediated electrochemical system. The kinetic parameters of the biosensor were analysed using the electrochemical Michaelis-Menten equation. The estimated apparent Michaelis-Menten constant, K-m', values for the biosensors were in the range of 1.41-3.9 mM. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1101 / 1110
页数:10
相关论文
共 21 条
[1]  
[Anonymous], ELECTROACTIVE POLY 2
[2]  
Bard A. J., 1980, ELECTROCHEMICAL METH
[3]   ELECTROCHEMISTRY OF CYTOCHROME-C(3) AT A LIPID-MODIFIED GRAPHITE ELECTRODE [J].
BIANCO, P ;
HALADJIAN, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 367 (1-2) :79-84
[4]   LIPID-MODIFIED PYROLYTIC-GRAPHITE ELECTRODES FOR THE STUDY OF NEGATIVELY CHARGED SPECIES [J].
BIANCO, P ;
HALADJIAN, J .
ELECTROANALYSIS, 1995, 7 (05) :442-446
[5]   Application of a large assembly of microelectrodes to the study of cytochrome-c and other redox proteins [J].
Bianco, P ;
Haladjian, J ;
Fletcher, S .
ELECTROANALYSIS, 1997, 9 (04) :307-310
[6]   Substrate docking algorithms and prediction of the substrate specificity of cytochrome P450(cam) and its L244A mutant [J].
DeVoss, JJ ;
Sibbesen, O ;
Zhang, ZP ;
deMontellano, PRO .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (24) :5489-5498
[7]   ELECTROCATALYTICALLY DRIVEN OMEGA-HYDROXYLATION OF FATTY-ACIDS USING CYTOCHROME-P450 4A1 [J].
FAULKNER, KM ;
SHET, MS ;
FISHER, CW ;
ESTABROOK, RW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (17) :7705-7709
[8]  
GOSSER DK, 1993, CYCLIC VOLTAMMETRY S, P45
[9]  
Greet R.R., 1990, INSTRUMENTAL METHODS, P178
[10]   Organic phase enzyme electrodes: Kinetics and analytical applications [J].
Iwuoha, EI ;
Smyth, MR ;
Lyons, MEG .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :53-75