The accuracy of non-invasively continuous total hemoglobin measurement by pulse CO-Oximetry undergoing acute normovolemic hemodilution and reinfusion of autologous blood

被引:15
作者
Saito, Junichi [1 ]
Kitayama, Masato [1 ]
Oishi, Masafumi [1 ]
Kudo, Tomoyuki [1 ]
Sawada, Masahiro [1 ]
Hashimoto, Hiroshi [2 ]
Hirota, Kazuyoshi [1 ]
机构
[1] Hirosaki Univ, Grad Sch Med, Dept Anesthesiol, Hirosaki, Aomori 0368562, Japan
[2] Hirosaki Univ Hosp, Div Surg Ctr, Hirosaki, Aomori, Japan
关键词
Hemoglobin; Hemodilution; Autologous blood transfusion; SPINE SURGERY; MICROCIRCULATION; RHEOLOGY;
D O I
10.1007/s00540-014-1863-1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background Non-invasively continuous total hemoglobin (SpHb) measurement has not been assessed adequately in acute bleeding and rapid blood transfusion during surgery. Thus, we have assessed the efficacy of SpHb during both acute normovolemic hemodilution (ANH) and autologous blood transfusion (ABT). Methods Twenty-four patients undergoing urological and gynecological surgery were enrolled. ANH was induced by withdrawing blood of 800 g with simultaneous fluid administration. When surgical hemostasis was completed, collected blood was reinfused. Measurement of SpHb, perfusion index (PI) and real total Hb (tHb) were done before and after each 400 ml blood removal (-0, -400, -800 ml) and reinfusion (+0, +400, +800 ml). Results A Bland-Altman analysis for repeated measurements showed a bias (precision) g/dl of 1.12 (1.25), 1.43 (1.24) and 1.10 (1.23) for all data, during ANH and during ABT, respectively. Additionally, a bias (precision) increased with a reduction in tHb (g/dl): >= 10.0; 0.74 (1.30), 8.0-10.0; 1.15 (1.12) and <8.0; 1.60 (1.28). Although the difference between SpHb and tHb was almost zero before anesthesia induction, it became significant just before ANH and did not change further by ANH and ABT. Significant correlations between SpHb and tHb for all data (r = 0.75, n = 228, p < 0.001) were observed. PI slightly correlated with the difference between SpHb and tHb (r = 0.38, n = 216, p < 0.001). Furthermore, before and after induction of anesthesia, PI also correlated with the difference between SpHb and tHb (r = 0.42, n = 23, p = 0.048 and r = 0.51, n = 22, p = 0.016, respectively). Conclusions The present data suggest that SpHb may overestimate tHb during ANH and ABT. In addition, PI and tHb levels had an impact on the accuracy of SpHb measurements.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 18 条
[1]   The Accuracy of Noninvasive Hemoglobin Measurement by Multiwavelength Pulse Oximetry After Cardiac Surgery [J].
Ba-Vinh Nguyen ;
Vincent, Jean-Louis ;
Nowak, Emmanuel ;
Coat, Michelle ;
Paleiron, Nicolas ;
Gouny, Pierre ;
Ould-Ahmed, Mehdi ;
Guillouet, Maite ;
Arvieux, Charles Christian ;
Gueret, Gildas .
ANESTHESIA AND ANALGESIA, 2011, 113 (05) :1052-1057
[2]   Continuous Noninvasive Hemoglobin Monitoring During Complex Spine Surgery [J].
Berkow, Lauren ;
Rotolo, Stephanie ;
Mirski, Erin .
ANESTHESIA AND ANALGESIA, 2011, 113 (06) :1396-1402
[3]   Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section [J].
Butwick, A. ;
Hilton, G. ;
Carvalho, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (02) :271-277
[4]   Intraoperative moderate acute normovolemic hemodilution associated with a comprehensive blood-sparing protocol in off-pump coronary surgery [J].
Casati, V ;
Benussi, S ;
Sandrelli, L ;
Grasso, MA ;
Spagnolo, S ;
D'Angelo, A .
ANESTHESIA AND ANALGESIA, 2004, 98 (05) :1217-1223
[5]   Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station [J].
Causey, Marlin Wayne ;
Miller, Seth ;
Foster, Andrew ;
Beekley, Alec ;
Zenger, David ;
Martin, Matthew .
AMERICAN JOURNAL OF SURGERY, 2011, 201 (05) :590-596
[6]   Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients [J].
Frasca, Denis ;
Dahyot-Fizelier, Claire ;
Catherine, Karen ;
Levrat, Quentin ;
Debaene, Bertrand ;
Mimoz, Olivier .
CRITICAL CARE MEDICINE, 2011, 39 (10) :2277-2282
[7]   Pulse oximeter perfusion index as an early indicator of sympathectomy after epidural anesthesia [J].
Ginosar, Y. ;
Weiniger, C. F. ;
Meroz, Y. ;
Kurz, V. ;
Bdolah-Abram, T. ;
Babchenko, A. ;
Nitzan, M. ;
Davidson, E. M. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (08) :1018-1026
[8]   Comparison of the Accuracy of Noninvasive Hemoglobin Monitoring by Spectrophotometry (SpHb) and HemoCue® with Automated Laboratory Hemoglobin Measurement [J].
Lamhaut, Lionel ;
Apriotesei, Roxana ;
Combes, Xavier ;
Lejay, Marc ;
Carli, Pierre ;
Vivien, Benoit .
ANESTHESIOLOGY, 2011, 115 (03) :548-554
[9]   The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution [J].
Macknet, Mark R. ;
Allard, Martin ;
Applegate, Richard L. ;
Rook, James .
ANESTHESIA AND ANALGESIA, 2010, 111 (06) :1424-1426
[10]   Erythrocyte rheology in microcirculation [J].
Maeda, N .
JAPANESE JOURNAL OF PHYSIOLOGY, 1996, 46 (01) :1-14