Lifetime measurements with a scanning positron microscope -: art. no. 067402

被引:77
|
作者
David, A [1 ]
Kögel, G [1 ]
Sperr, P [1 ]
Triftshäuser, W [1 ]
机构
[1] Univ Bundeswehr Munchen, Inst Nukl Festkorperphys, D-85577 Neubiberg, Germany
关键词
D O I
10.1103/PhysRevLett.87.067402
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
First lifetime results obtained with a scanning positron microscope will be presented. A pulsed positron beam with a variable energy from 0.5 to 20 keV, with a spot diameter of 2 mum, can be electronically scanned over an area of 0.6 x 0.6 mm(2). This beam is formed after a double-stage stochastic cooling (moderation) of positrons emitted from a radioactive isotope. Included in the system is a conventional scanning electron microprobe for surface analysis. Three-dimensional positron lifetime spectra or a GaAs sample with a small surface scratch reveal the range due to the mechanical damage.
引用
收藏
页码:67402 / 1
页数:4
相关论文
共 50 条
  • [31] Lifetime measurements of excited Kπ=0+ bands in 178Hf -: art. no. 031301
    Aprahamian, A
    de Haan, RC
    Börner, HG
    Lehmann, H
    Doll, C
    Jentschel, M
    Bruce, AM
    Piepenbring, R
    PHYSICAL REVIEW C, 2002, 65 (03) : 4
  • [32] Investigation of the decay out of superdeformed bands in 194Hg by lifetime measurements -: art. no. 054309
    Dewald, A
    Kühn, R
    Peusquens, R
    von Brentano, P
    Krücken, R
    Deleplanque, MA
    Lee, IY
    Clark, RM
    Fallon, P
    Macchiavelli, AO
    MacLeod, RW
    Stephens, FS
    Khoo, TL
    Reiter, P
    Hauschild, K
    PHYSICAL REVIEW C, 2001, 64 (05): : 543091 - 543096
  • [33] Research on a real-time scanning tunneling microscope data acquisition system - art. no. 67233A
    Xu Chang
    Xiao Baoping
    Xu Lijun
    3RD INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PARTS 1-3, 2007, 6723 : A7233 - A7233
  • [34] A selective control of narrow groove parameters with scanning differential heterodyne microscope - art. no. 67281L
    Baranov, D. V.
    Zolotov, E. M.
    ICONO 2007: NOVEL PHOTONICS MATERIALS; OPTICS AND OPTICAL DIAGNOSTICS OF NANOSTRUCTURES, 2007, 6728 : L7281 - L7281
  • [35] Measurement of the (Σ)over-bar- lifetime and direct comparison with the Σ+ lifetime -: art. no. 031101
    Barbosa, RF
    Albuquerque, IF
    Bondar, NF
    Carrigan, R
    Chen, D
    Cooper, PS
    Dai, LS
    Denisov, AS
    Dobrovolsky, AC
    Dubbs, T
    Endler, AMF
    Escobar, CO
    Foucher, M
    Golovtsov, VL
    Gottschalk, H
    Gouffon, P
    Grachev, VT
    Khanzadeev, AV
    Kubantsev, MA
    Kuropatkin, NP
    Lach, J
    Langland, J
    Lang, PF
    Li, CZ
    Li, YS
    Luksys, M
    Mahon, JRP
    McCliment, E
    Morelos, A
    Newsom, C
    Maia, MCP
    Samsonov, VM
    Schegelsky, VA
    Shi, HZ
    Smith, VJ
    Tang, FU
    Terentyev, NK
    Timm, S
    Tkatch, II
    Uvarov, LN
    Vorobyov, AA
    Jie, Y
    Zhao, WH
    Zheng, SC
    Zhong, YY
    PHYSICAL REVIEW D, 2000, 61 (03):
  • [37] Quantum cloning and distributed measurements -: art. no. 042308
    Bruss, D
    Calsamiglia, J
    Lütkenhaus, N
    PHYSICAL REVIEW A, 2001, 63 (04): : 1 - 9
  • [38] Electromagnetic signals and spectral measurements - art. no. 659410
    Moskaletz, Oleg D.
    Lasers for Measurements and Information Transfer 2006, 2007, 6594 : 59410 - 59410
  • [39] Purity estimation with separable measurements -: art. no. 110504
    Bagan, E
    Ballester, MA
    Muñoz-Tapia, R
    Romero-Isart, O
    PHYSICAL REVIEW LETTERS, 2005, 95 (11)
  • [40] Amplitude measurements of Faraday waves -: art. no. 036305
    Wernet, A
    Wagner, C
    Papathanassiou, D
    Müller, HW
    Knorr, K
    PHYSICAL REVIEW E, 2001, 63 (03): : 363051 - 363059