Thin-film microbiosensors for glucose-lactate monitoring

被引:92
作者
Jobst, G
Moser, I
Varahram, M
Svasek, P
Aschauer, E
Trajanoski, Z
Wach, P
Kotanko, P
Skrabal, F
Urban, G
机构
[1] GRAZ UNIV TECHNOL,INST BIOMED ENGN,DEPT BIOPHYS,A-8010 GRAZ,AUSTRIA
[2] KRANKENHAUS BARMHERZIGEN BRUDER,DEPT INTERNAL MED,A-8020 GRAZ,AUSTRIA
关键词
D O I
10.1021/ac950630x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized device for simultaneous measurement of glucose and lactate levels was produced by means of photopatterning of enzyme-containing photosensitive membrane precursors, This device shows no cross-talk and a lifetime for both the glucose and the lactate sensors of more than 2 weeks when continuously operated in undiluted bovine serum, Linear response ranges of up to 40 mM for glucose and 25 mM for L-lactate, in combination with 95% response times of <30 s, were realized. The devices are mass produced by means of thin-film technology on flexible carriers to give catheter-type multisensing devices for in vivo applications, Ex vivo experiments, performed with human volunteers, where the device was continuously operated in an extracorporeal, undiluted, heparinized blood stream for 6 h, gave a correlation of r > 0.98 with respect to laboratory techniques. Subcutaneous measurements of glucose levels in pigs were close to the corresponding blood levels obtained without in vivo calibration.
引用
收藏
页码:3173 / 3179
页数:7
相关论文
共 29 条
[1]   IMPROVEMENT IN THE LONG-TERM STABILITY OF AN AMPEROMETRIC GLUCOSE SENSOR SYSTEM BY INTRODUCING A CELLULOSE MEMBRANE OF BACTERIAL ORIGIN [J].
AMMON, HPT ;
EGE, W ;
OPPERMANN, M ;
GOPEL, W ;
EISELE, S .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :466-471
[2]   INTEGRATED BLOOD-GAS SENSOR FOR PO2, PCO2 AND PH [J].
ARQUINT, P ;
VANDENBERG, A ;
VANDERSCHOOT, BH ;
DEROOIJ, NF ;
BUHLER, H ;
MORF, WE ;
DURSELEN, LFJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) :340-344
[3]   CORTICAL EVOKED-POTENTIAL AND EXTRACELLULAR K+ AND H+ AT CRITICAL LEVELS OF BRAIN ISCHEMIA [J].
ASTRUP, J ;
SYMON, L ;
BRANSTON, NM ;
LASSEN, NA .
STROKE, 1977, 8 (01) :51-57
[4]   A CONTINUOUS, IMPLANTABLE LACTATE SENSOR [J].
BAKER, DA ;
GOUGH, DA .
ANALYTICAL CHEMISTRY, 1995, 67 (09) :1536-1540
[5]  
BILITEWSKI U, 1992, TRENDS ELECTROCHEMIC, P59
[6]  
CLARKE WL, 1984, DIABETES CARE, V5, P622
[7]  
ERICKSON KA, 1993, CLIN CHEM, V39, P283
[8]   ELECTROPOLYMERIZED FILMS TO PREVENT INTERFERENCES AND ELECTRODE FOULING IN BIOSENSORS [J].
GEISE, RJ ;
ADAMS, JM ;
BARONE, NJ ;
YACYNYCH, AM .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) :151-160
[9]   GLUCOSE SENSOR BASED ON A FIELD-EFFECT TRANSISTOR WITH A PHOTOLITHOGRAPHICALLY PATTERNED GLUCOSE-OXIDASE MEMBRANE [J].
HANAZATO, Y ;
NAKAKO, M ;
MAEDA, M ;
SHIONO, S .
ANALYTICA CHIMICA ACTA, 1987, 193 :87-96
[10]   INTEGRATED DIFFERENTIAL ENZYME SENSORS USING HYDROGEN AND FLUORIDE-ION SENSITIVE MULTIGATE FETS [J].
HINTSCHE, R ;
DRANSFELD, I ;
SCHELLER, F ;
PHAM, MT ;
HOFFMANN, W ;
HUELLER, J ;
MORITZ, W .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (04) :327-334