Graphical display of tactile sensing data with application in minimally invasive surgery

被引:12
作者
Dargahi, Javad [1 ]
Najarian, Siamak [2 ]
Rarnezanifard, Reza [1 ]
机构
[1] Concordia Univ, Dept Mech & Ind Engn, Montreal, PQ H3G 1M8, Canada
[2] Amirkabir Univ Technol, Fac Biomed Engn, Biomech Dept,Ctr Excellence Biomed Engn Iran, Artificial Tactile Sensing & Robot Surg Lab, Tehran, Iran
来源
CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE | 2007年 / 32卷 / 03期
关键词
sensed objects; softness measurements; tactile sensing;
D O I
10.1109/CJECE.2007.4413126
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, the design of a hardware and software system for graphical representation of tactile sensing data is described in detail. The signal processing is developed using LabView 7 software. The signals from the sensors are processed, and then various tactile properties of the grasped material are extracted. The tactile information includes softness, stress distribution, and lumps. This information is displayed by means of a colour coding method. The technical specifications of the hardware and data acquisition system are described in detail. The system receives signals from the sensors, transforms them into digital signals, and then transmits them to a personal computer. The developed software is also presented, and its capabilities are discussed. Using the designed system, it is possible to determine the softness of objects that come into contact with it. To serve as sensing elements, two piezoelectric films made Of polyvinylidene difluoride are incorporated into the sensing assembly, and the combination of the resulting output voltages is related to the object softness. As a practical application, the sensor assembly is integrated with a commercially available endoscopic grasper which has been modified for the purpose of this research.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 39 条
[1]  
Andrzej O., 2003, MEAS SCI REV, V3, P111
[2]  
BARCOHEN Y, 2000, P INT C SMART SYST R, P7
[3]  
Bicchi A., 1996, Proceedings. 1996 IEEE International Conference on Robotics and Automation (Cat. No.96CH35857), P884, DOI 10.1109/ROBOT.1996.503884
[4]   The development and characterisation of conducting polymeric-based sensing devices. [J].
Brady, S ;
Lau, KT ;
Megill, W ;
Wallace, GG ;
Diamond, D .
SYNTHETIC METALS, 2005, 154 (1-3) :25-28
[5]  
Brouwer I, 2001, ST HEAL T, V81, P69
[6]   FEEDBACK-REGULATION OF HAND GRASP OPENING AND CONTACT FORCE DURING STIMULATION OF PARALYZED MUSCLE [J].
CRAGO, PE ;
NAKAI, RJ ;
CHIZECK, HJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (01) :17-28
[7]   Advances in tactile sensors design/manufacturing and its impact on robotics applications - a review [J].
Dargahi, A ;
Najarian, S .
INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2005, 32 (03) :268-281
[8]   A micromachined piezoelectric tactile sensor for an endoscopic grasper - Theory, fabrication and experiments [J].
Dargahi, J ;
Parameswaran, M ;
Payandeh, S .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (03) :329-335
[9]   Human tactile perception as a standard for artificial tactile sensing - a review [J].
Dargahi, J ;
Najarian, S .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2004, 1 (01) :23-35
[10]  
Dargahi J, 2005, SENSOR MATER, V17, P7