Turbulent thermal, fluid flow and thermodynamic characteristics in a plain tube fitted with overlapped multiple twisted tapes

被引:44
|
作者
Hong, Yuxiang [1 ,2 ]
Du, Juan [1 ]
Wang, Shuangfeng [2 ]
机构
[1] Lishui Univ, Dept Chem & Chem Engn, Lishui 323000, Peoples R China
[2] South China Univ Technol, Minist Educ, Key Lab Enhanced Heat Transfer & Energy Conservat, Guangzhou 510641, Guangdong, Peoples R China
关键词
Multiple twisted tapes; Heat transfer enhancement; Entropy generation; Entransy dissipation; Swirl flow; HEAT-TRANSFER ENHANCEMENT; PERFORMANCE EVALUATION CRITERIA; FIELD SYNERGY PRINCIPLE; EXCHANGER TUBE; CIRCULAR TUBE; TRANSFER OPTIMIZATION; TRANSFER AUGMENTATION; ENTRANSY DISSIPATION; TRANSFER SURFACES; SWIRL GENERATORS;
D O I
10.1016/j.ijheatmasstransfer.2017.08.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
Turbulent thermal hydraulic characteristics in a plain tube by using overlapped multiple twisted tapes (MTTs) with counter large/small combinations (C-L/S-C) were experimentally investigated. Reynolds number (Re) ranged from 5800 to 19200, tape number changed from 3 to 5 and overlapped twisted ratios (PI :P2) were 0.74 to 2.97. By using air as working fluid, heat transfer tests were performed under the constant heat flux conditions and pressure drop experiments were conducted at the isothermal conditions. Nusselt number (Nu) and friction factor (f), overall thermal performance evaluation criterion (PEC), entropy generation and entransy dissipation in the MTTs were compared. The results show that Nu and f increase with increasing tape number and decreasing overlapped twisted ratio. The experimental results demonstrates that both increasing tape number and decreasing overlapped twisted ratio result in the reduction of entropy generation due to heat transfer and the rise of entropy generation due to friction resistance. It is found that the indicator of equivalent temperature difference, reflecting entransy dissipation and heat transfer ability, has the same sequence to that of the heat transfer behaviors. In the scope of this study, both the maximum Nu and the largest increased f are obtained in the 5MTTs with values respectively about 98.4% higher and 9.13 times than that in the plain tube while the highest PEC is found in the 3MTTs with P1 :P2 = 0.74 with a value of being about 1.08. The least total entropy generation is gained by the 3MTTs with P1 :P2 = 0.74 at Re = 17090 and the smallest entransy dissipation per unit energy is achieved by the 5MTTs under Re = 17294. Furthermore, thermal hydraulic empirical correlations with deviations of 5% are developed and comparisons with previous studies are also conducted. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:551 / 565
页数:15
相关论文
共 50 条
  • [21] Thermal characteristics in a heat exchanger tube fitted with dual twisted tape elements in tandem
    Eiamsa-ard, Smith
    Thianpong, Chinaruk
    Eiamsa-ard, Petpices
    Promvonge, Pongjet
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (01) : 39 - 46
  • [22] Effect of square wings in multiple square perforated twisted tapes on fluid flow and heat transfer of heat exchanger tube
    Suri, Amar Raj Singh
    Kumar, Anil
    Maithani, Rajesh
    CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 28 - 43
  • [23] CFD study of heat transfer enhancement and fluid flow characteristics of turbulent flow through tube with twisted tape inserts
    Tusar, Mehedi
    Noman, Abdullah
    Islam, Majedul
    Yarlagadda, Prasad
    Salam, Bodius
    2ND INTERNATIONAL CONFERENCE ON ENERGY AND POWER (ICEP2018), 2019, 160 : 715 - 722
  • [24] A numerical study on thermal-hydraulic characteristics of turbulent flow through a circular tube fitted with pipe inserts
    Tu, Wenbin
    Wang, Yun
    Tang, Yong
    APPLIED THERMAL ENGINEERING, 2016, 101 : 413 - 421
  • [25] THERMAL CHARACTERISTICS OF A HEAT EXCHANGER TUBE FITTED WITH DIFFERENT PERIPHERALLY-CUT TWISTED TAPE INSERTS IN LAMINAR FLOW
    Zheng G.
    Zhang W.
    Man C.
    Sun P.
    Man, Changzhong (mcz640927@dlut.edu.cn), 1600, Begell House Inc. (52): : 29 - 42
  • [26] THERMAL CHARACTERISTICS OF A HEAT EXCHANGER TUBE FITTED WITH DIFFERENT PERIPHERALLY-CUT TWISTED TAPE INSERTS IN LAMINAR FLOW
    Zheng, Guowei
    Zhang, Wenbo
    Man, Changzhong
    Sun, Peiyan
    HEAT TRANSFER RESEARCH, 2021, 52 (12) : 29 - 42
  • [27] Performance investigation of heat exchanger tube fitted with hyperbolic-cut twisted tape in turbulent flow
    Rajan, Abhijit
    Prasad, Laljee
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2022, 236 (14) : 8134 - 8149
  • [28] Fluid Flow and Turbulent Convectional Heat Transfer Simulation in Twisted Elliptical Tube
    Afrouzia, H. Hassanzadeh
    Azizib, A. A. Sheikhi
    Jahanianb, O.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2025, 38 (06): : 1307 - 1319
  • [29] Turbulent thermal-hydraulic characteristics in a spiral corrugated waste heat recovery heat exchanger with perforated multiple twisted tapes
    Hong, Yuxiang
    Zhao, Lei
    Huang, Yongchun
    Li, Qing
    Jiang, Jiajie
    Du, Juan
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 184
  • [30] Heat Transfer and Fluid Flow Characteristics in a Heat Exchanger Tube Fitted With Inserts
    Mahfouz, Alaa E.
    Abdelmaksoud, Waleed A.
    Khalil, Essam E.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2018, 10 (03)