A dual spectrophotometric/contactless conductivity detector for CE determination of incompletely separated amino acids

被引:23
|
作者
Zikmundova, Jana [1 ]
Tuma, Petr [2 ]
Opekar, Frantisek [1 ]
机构
[1] Charles Univ Prague, UNESCO Lab Environm Electrochem, Dept Analyt Chem, Prague 12840 2, Czech Republic
[2] Charles Univ Prague, Inst Biochem Cell & Mol Biol, Fac Med 3, Prague, Czech Republic
关键词
amino acids; CE; contactless conductivity detector; dual detector; UV detector;
D O I
10.1002/jssc.200700438
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new application is described of a dual photometric/contactless conductivity detector to CE determination of incompletely separated compounds. These compounds are differentiated when one of them provides signals in both the cells of the detector, whereas the other yields a signal in only one cell. The technique has been applied to determination of proline and tyrosine in a dietary supplement.
引用
收藏
页码:353 / 355
页数:3
相关论文
共 50 条
  • [31] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF AMINO-ACIDS BASED ON AN IMMOBILIZED COPPER(II) ZINCON SYSTEM
    ZAMORA, LL
    CALATAYUD, JM
    ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 601 - 605
  • [32] Fe NPs and MWCNTs based electrode as FIA detector for determination of amino acids in hypothalamus microdialysis fluids
    Wang, Jing
    Liu, Xueying
    Wang, Yiting
    Yu, Lei
    Peng, Hui
    Zhu, Jian-Zhong
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 834 - 841
  • [33] Sequential-injection spectrophotometric determination of amino acids using 2,4,6-trinitrobenzenesulphonic acid
    van Staden, JF
    McCormack, T
    ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) : 163 - 170
  • [34] CONTINUOUS-FLOW SPECTROPHOTOMETRIC DETERMINATION OF AMINO-ACIDS WITH 1,2-NAPHTHOQUINONE-4-SULFONATE REAGENT
    SAURINA, J
    HERNANDEZCASSOU, S
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 414 - 420
  • [35] Separation and determination of B vitamins and essential amino acids in health drinks by CE-LIF with simultaneous derivatization
    Zhao, Danyue
    Lu, Minghua
    Cai, Zongwei
    ELECTROPHORESIS, 2012, 33 (15) : 2424 - 2432
  • [36] Determination of α-hydroxy acids and their enantiomers in fruit juices by ligand exchange CE with a dual central metal ion system
    Kodama, Shuji
    Aizawa, Sen-ichi
    Taga, Atsushi
    Yamamoto, Atsushi
    Honda, Yoshitaka
    Suzuki, Kentaro
    Kemmei, Tomoko
    Hayakawa, Kazuichi
    ELECTROPHORESIS, 2013, 34 (9-10) : 1327 - 1333
  • [37] Development of flow systems incorporating membraneless vaporization units and flow-through contactless conductivity detector for determination of dissolved ammonium and sulfide in canal water
    Alahmad, Waleed
    Pluangklang, Thanakorn
    Mantim, Thitirat
    Cerda, Victor
    Wilairat, Prapin
    Ratanawimarnwong, Nuanlaor
    Nacapricha, Duangjai
    TALANTA, 2018, 177 : 34 - 40
  • [38] The use of solid phase reactors as the source of a catalytic solution. The indirect flow-injection spectrophotometric determination of amino acids
    Torro, IG
    Mateo, JVG
    Calatayud, JM
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1997, 8 (01) : 59 - 64
  • [39] CE with sequential light-emitting diodeinduced fluorescence and electro-chemiluminescence detections for the determination of amino acids and alkaloids
    Chang, Po-Ling
    Lee, Kun-Hong
    Hu, Cho-Chun
    Chang, Huan-Tsung
    ELECTROPHORESIS, 2007, 28 (07) : 1092 - 1099
  • [40] SOME OBSERVATIONS ON THE AUTOMATION BY FLOW-INJECTION ANALYSIS OF THE SPECTROPHOTOMETRIC DETERMINATION OF AMINO-ACIDS AND PROTEINS WITH ORTHO-PHTHALALDEHYDE
    HERNANDEZ, MJM
    VIVES, SS
    ALVAREZCOQUE, MCG
    MIKROCHIMICA ACTA, 1992, 108 (3-6) : 293 - 298