Rapid Determination of Vitamins D2 and D3 in Dairy Products by High-Performance Liquid Chromatography after Solid Phase Extraction Based on Polystyrene/Polypyrrole Composite Nanofibers

被引:3
|
作者
Han, Qing [1 ]
Wei, Lanlan [2 ]
Deng, Guozhe [1 ]
Sun, Ying [1 ]
Deng, Jianjun [3 ]
Tang, Zigang [2 ]
Fan, Jinhui [1 ]
Wang, Xia [1 ]
Kang, Xuejun [1 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, Minist Educ, Res Ctr Learning Sci,Key Lab Child Dev & Learning, Nanjing 210096, Peoples R China
[2] Southeast Univ, Sch Publ Hlth, Minist Educ, Key Lab Environm Med & Engn, Nanjing 210096, Peoples R China
[3] Suzhou Dongqi Biol Technol Co, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
nanofibers; solid-phase extraction; vitamin D-2; vitamin D-3; dairy products; FAT-SOLUBLE VITAMINS; MILK; SUPPLEMENTS; PARTICLES; DISEASES; REMOVAL; FIBER;
D O I
10.21577/0103-5053.20200007
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The detection of vitamin D in complex samples is challenging because of the instability of vitamin D in sample preparation. To resolve this problem. packed-fiber solid-phase extraction (PFSPE) has been successfully developed for the pre-treatment of samples containing vitamin D-2 (D-2) and vitamin D-3 (D-3) in dairy products. Based on PFSPE, vitamin D could avoid oxidation because of the shorter extraction time. The adsorbent materials, polystyrene/polypyrrole (PS/PPy) nanofibers, were prepared by electrospinning of PS and in situ polymerization of PPy on the surface of PS nanofibers. The linearity was within the range of 1-2000 ng mL(-1) in dairy solution, and the recoveries were 91.9-109.1% with a relative standard deviation (RSD) < 13.6%. Therefore, the prepared method could be used for the detection of D-2 and D-3 in dairy products.
引用
收藏
页码:1216 / 1224
页数:9
相关论文
共 50 条
  • [41] In-situ fabrication of zeolite imidazole framework@hydroxyapatite composite for dispersive solid-phase extraction of benzodiazepines and their determination with high-performance liquid chromatography-VWD detection
    Li, Zi-Ling
    Zhang, Zi-Yang
    Zhao, Teng-Wen
    Meng, Chun-Yan
    Zhang, Qian-Ying
    Wang, Man-Man
    MICROCHIMICA ACTA, 2020, 187 (09)
  • [42] Determination of trace bisphenol A in environmental water by high-performance liquid chromatography using magnetic reduced graphene oxide based solid-phase extraction coupled with dispersive liquid-liquid microextraction
    Li, Danping
    Ma, Xiaoguo
    Wang, Rui
    Yu, Yumian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (05) : 1165 - 1172
  • [43] Determination of zearalenone in grains by high-performance liquid chromatography-tandem mass spectrometry after solid-phase extraction with RP-18 columns or immunoaffinity columns
    Zöllner, P
    Jodlbauer, J
    Lindner, W
    JOURNAL OF CHROMATOGRAPHY A, 1999, 858 (02) : 167 - 174
  • [44] Simultaneous Determination of Five Benzimidazoles in Agricultural Foods by Core-Shell Magnetic Covalent Organic Framework Nanoparticle-Based Solid-Phase Extraction Coupled with High-Performance Liquid Chromatography
    Li, Shuming
    Liang, Qian
    Ahmed, Shadi Ali Hassen
    Zhang, Jing
    FOOD ANALYTICAL METHODS, 2020, 13 (05) : 1111 - 1118
  • [45] Application of Graphene-based Solid-Phase Extraction Coupled with Ultra High-performance Liquid Chromatography-Tandem Mass Spectrometry for Determination of Macrolides in Fish Tissues
    Jianbing Wu
    Yongsheng Qian
    Chuanlan Zhang
    Tinglu Zheng
    Linyao Chen
    Yanbin Lu
    Huizhong Wang
    Food Analytical Methods, 2013, 6 : 1448 - 1457
  • [46] Study of molecularly imprinted solid-phase extraction of gonyautoxins 2,3 in the cultured dinoflagellate Alexandrium tamarense by high-performance liquid chromatography with fluorescence detection
    Lian, Zi-Ru
    Wang, Jiang-Tao
    ENVIRONMENTAL POLLUTION, 2013, 182 : 385 - 391
  • [47] Monitoring of Carbendazim and Thiabendazole in Fruits and Vegetables by SiO2@NiO-Based Solid-Phase Extraction Coupled to High-Performance Liquid Chromatography-Fluorescence Detector
    Qiong-Wei Yu
    Huan Sun
    Kuan Wang
    Hai-Bo He
    Yu-Qi Feng
    Food Analytical Methods, 2017, 10 : 2892 - 2901
  • [48] Monitoring of Carbendazim and Thiabendazole in Fruits and Vegetables by SiO2@NiO-Based Solid-Phase Extraction Coupled to High-Performance Liquid Chromatography-Fluorescence Detector
    Yu, Qiong-Wei
    Sun, Huan
    Wang, Kuan
    He, Hai-Bo
    Feng, Yu-Qi
    FOOD ANALYTICAL METHODS, 2017, 10 (08) : 2892 - 2901
  • [49] Determination of chlorophenoxy acid herbicides by using a zirconium-based metal-organic framework as special sorbent for dispersive micro-solid-phase extraction and high-performance liquid chromatography
    Xia, Lian
    Liu, Lijie
    Xu, Xianli
    Zhu, Fenfen
    Wang, Xiuli
    Zhang, Keyun
    Yang, Xuncheng
    You, Jinmao
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (06) : 2241 - 2248
  • [50] Simultaneous Determination of Five Benzimidazoles in Agricultural Foods by Core-Shell Magnetic Covalent Organic Framework Nanoparticle–Based Solid-Phase Extraction Coupled with High-Performance Liquid Chromatography
    Shuming Li
    Qian Liang
    Shadi Ali Hassen Ahmed
    Jing Zhang