Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding

被引:35
|
作者
Karampinos, Dimitrios C. [1 ]
Banerjee, Suchandrima [2 ]
King, Kevin F. [3 ]
Link, Thomas M. [1 ]
Majumdar, Sharmila [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[3] GE Healthcare, Global Appl Sci Lab, Waukesha, WI USA
基金
美国国家卫生研究院;
关键词
skeletal muscle; high-resolution DTI; stimulated echo; single-shot EPI; IN-VIVO; FIBER TRACKING; T-2; RELAXATION; SPIN-ECHO; ARCHITECTURE; ANISOTROPY; DISTORTION; MOTION; SENSE; DTI;
D O I
10.1002/nbm.1791
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can noninvasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single-shot diffusion-weighted echo planar imaging (DW-EPI) can be hindered by the inherently low signal-to-noise ratio (SNR) of muscle DW-EPI because of the short muscle T2 and the high sensitivity of single-shot EPI to off-resonance effects and T2* blurring. In this article, eddy current-compensated diffusion-weighted stimulated-echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and to reduce the sensitivity to distortions and T2* blurring in high-resolution skeletal muscle single-shot DW-EPI. An analytical framework is developed to optimize the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B0-induced distortions, T2* blurring effects and tissue incoherent motion effects. On the basis of the selected parameters in a high-resolution skeletal muscle single-shot DW-EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase-encoding direction and SNR. In?vivo results show that high-resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T2* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from a reduction in partial volume effects for resolving multi-pennate muscles and muscles with small cross-sections in calf muscle DTI. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:766 / 778
页数:13
相关论文
共 50 条
  • [41] Fast diffusion tensor imaging and tractography of the whole cervical spinal cord using point spread function corrected echo planar imaging
    Lundell, Henrik
    Barthelemy, Dorothy
    Biering-Sorensen, Fin
    Cohen-Adad, Julien
    Nielsen, Jens Bo
    Dyrby, Tim B.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 144 - 149
  • [42] Diffusion-Weighted Echo Planar Imaging using MUltiplexed Sensitivity Encoding and Reverse Polarity Gradient in Head and Neck Cancer: An Initial Study
    Konar, Amaresha Shridhar
    Fung, Maggie
    Paudyal, Ramesh
    Oh, Jung Hun
    Mazaheri, Yousef
    Hatzoglou, Vaios
    Shukla-Dave, Amita
    TOMOGRAPHY, 2020, 6 (02) : 231 - 240
  • [43] Self-navigated multishot echo-planar pulse sequence for high-resolution diffusion-weighted imaging
    Nunes, RG
    Jezzard, P
    Behrens, TEJ
    Clare, S
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1474 - 1478
  • [44] Echo planar imaging with compressed sensitivity encoding (EPICS): Usefulness for head and neck diffusion-weighted MRI
    Yoshida, Naofumi
    Nakaura, Takeshi
    Morita, Kosuke
    Yoneyama, Masami
    Tanoue, Shota
    Yokota, Yasuhiro
    Uetani, Hiroyuki
    Nagayama, Yasunori
    Kidoh, Masafumi
    Azuma, Minako
    Hirai, Toshinori
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [45] Single-shot T2 mapping using overlapping-echo detachment planar imaging and a deep convolutional neural network
    Cai, Congbo
    Wang, Chao
    Zeng, Yiqing
    Cai, Shuhui
    Liang, Dong
    Wu, Yawen
    Chen, Zhong
    Ding, Xinghao
    Zhong, Jianhui
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 2202 - 2214
  • [46] Accurate brain volumetry with diffusion-weighted spin-echo single-shot echo-planar-imaging and dual-clustering segmentation: Comparison with volumetry-validated quantitative magnetic resonance imaging
    Watanabe, Memi
    Sakai, Osamu
    Norbash, Alexander M.
    Jara, Hernan
    MEDICAL PHYSICS, 2010, 37 (03) : 1183 - 1190
  • [47] Distortion-free diffusion tensor imaging for evaluation of lumbar nerve roots: Utility of direct coronal single-shot turbo spin-echo diffusion sequence
    Sakai, Takayuki
    Doi, Kunio
    Yoneyama, Masami
    Watanabe, Atsuya
    Miyati, Tosiaki
    Yanagawa, Noriyuki
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 78 - 85
  • [48] Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging
    Dong, Zijing
    Wang, Fuyixue
    Chan, Kwok-Shing
    Reese, Timothy G.
    Bilgic, Berkin
    Marques, Jose P.
    Setsompop, Kawin
    NEUROIMAGE, 2021, 232
  • [49] BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI
    Bhavsar, Saurabh
    Zvyagintsev, Mikhail
    Mathiak, Klaus
    NEUROIMAGE, 2014, 84 : 65 - 75
  • [50] Quantification of Diffusivities of the Human Cervical Spinal Cord Using a 2D Single-Shot Interleaved Multisection Inner Volume Diffusion-Weighted Echo-Planar Imaging Technique
    Kim, T. H.
    Zollinger, L.
    Shi, X. F.
    Kim, S. E.
    Rose, J.
    Patel, A. A.
    Jeong, E. K.