共 50 条
Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding
被引:35
|作者:
Karampinos, Dimitrios C.
[1
]
Banerjee, Suchandrima
[2
]
King, Kevin F.
[3
]
Link, Thomas M.
[1
]
Majumdar, Sharmila
[1
]
机构:
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[3] GE Healthcare, Global Appl Sci Lab, Waukesha, WI USA
基金:
美国国家卫生研究院;
关键词:
skeletal muscle;
high-resolution DTI;
stimulated echo;
single-shot EPI;
IN-VIVO;
FIBER TRACKING;
T-2;
RELAXATION;
SPIN-ECHO;
ARCHITECTURE;
ANISOTROPY;
DISTORTION;
MOTION;
SENSE;
DTI;
D O I:
10.1002/nbm.1791
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can noninvasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single-shot diffusion-weighted echo planar imaging (DW-EPI) can be hindered by the inherently low signal-to-noise ratio (SNR) of muscle DW-EPI because of the short muscle T2 and the high sensitivity of single-shot EPI to off-resonance effects and T2* blurring. In this article, eddy current-compensated diffusion-weighted stimulated-echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and to reduce the sensitivity to distortions and T2* blurring in high-resolution skeletal muscle single-shot DW-EPI. An analytical framework is developed to optimize the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B0-induced distortions, T2* blurring effects and tissue incoherent motion effects. On the basis of the selected parameters in a high-resolution skeletal muscle single-shot DW-EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase-encoding direction and SNR. In?vivo results show that high-resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T2* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from a reduction in partial volume effects for resolving multi-pennate muscles and muscles with small cross-sections in calf muscle DTI. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:766 / 778
页数:13
相关论文