Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding

被引:35
|
作者
Karampinos, Dimitrios C. [1 ]
Banerjee, Suchandrima [2 ]
King, Kevin F. [3 ]
Link, Thomas M. [1 ]
Majumdar, Sharmila [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[3] GE Healthcare, Global Appl Sci Lab, Waukesha, WI USA
基金
美国国家卫生研究院;
关键词
skeletal muscle; high-resolution DTI; stimulated echo; single-shot EPI; IN-VIVO; FIBER TRACKING; T-2; RELAXATION; SPIN-ECHO; ARCHITECTURE; ANISOTROPY; DISTORTION; MOTION; SENSE; DTI;
D O I
10.1002/nbm.1791
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can noninvasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single-shot diffusion-weighted echo planar imaging (DW-EPI) can be hindered by the inherently low signal-to-noise ratio (SNR) of muscle DW-EPI because of the short muscle T2 and the high sensitivity of single-shot EPI to off-resonance effects and T2* blurring. In this article, eddy current-compensated diffusion-weighted stimulated-echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and to reduce the sensitivity to distortions and T2* blurring in high-resolution skeletal muscle single-shot DW-EPI. An analytical framework is developed to optimize the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B0-induced distortions, T2* blurring effects and tissue incoherent motion effects. On the basis of the selected parameters in a high-resolution skeletal muscle single-shot DW-EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase-encoding direction and SNR. In?vivo results show that high-resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T2* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from a reduction in partial volume effects for resolving multi-pennate muscles and muscles with small cross-sections in calf muscle DTI. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:766 / 778
页数:13
相关论文
共 50 条
  • [1] Fast low-angle shot diffusion tensor imaging with stimulated echo encoding in the muscle of rabbit shank
    Hiepe, Patrick
    Herrmann, Karl-Heinz
    Guellmar, Daniel
    Ros, Christian
    Siebert, Tobias
    Blickhan, Reinhard
    Hahn, Klaus
    Reichenbach, Juergen R.
    NMR IN BIOMEDICINE, 2014, 27 (02) : 146 - 157
  • [2] Comparison of single-shot echo-planar and line scan protocols for diffusion tensor-imaging
    Kubicki, M
    Maier, SE
    Westin, CF
    Mamata, H
    Ersner-Hershfield, H
    Estepar, R
    Kikinis, R
    Jolesz, FA
    McCarley, RW
    Shenton, ME
    ACADEMIC RADIOLOGY, 2004, 11 (02) : 224 - 232
  • [3] Considerations for gradient echo echo planar imaging of skeletal muscle
    Davis A.D.
    Critical Reviews in Biomedical Engineering, 2018, 46 (03) : 201 - 219
  • [4] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [5] Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test-retest reliability and comparison to spin echo diffusion tensor imaging
    Marth, Adrian Alexander
    Sommer, Stefan
    Feiweier, Thorsten
    Sutter, Reto
    Nanz, Daniel
    von Deuster, Constantin
    NMR IN BIOMEDICINE, 2025, 38 (01)
  • [6] Single-shot diffusion trace spectroscopic imaging using radial echo planar trajectories
    Saucedo, Andres
    Thomas, M. Albert
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (03) : 926 - 944
  • [7] Comparison of Twice Refocused Spin Echo Versus Stimulated Echo Diffusion Tensor Imaging for Tracking Muscle Fibers
    Noehren, Brian
    Andersen, Anders
    Feiweier, Thorsten
    Damon, Bruce
    Hardy, Peter
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) : 624 - 632
  • [8] Optimizing signal-to-noise ratio of high-resolution parallel single-shot diffusion-weighted echo-planar imaging at ultrahigh field strengths
    Reischauer, Carolin
    Vorburger, Robert S.
    Wilm, Bertram J.
    Jaermann, Thomas
    Boesiger, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 679 - 690
  • [9] Ultrafast bold fMRI using single-shot spin-echo echo planar imaging
    Boujraf, Said
    Summers, Paul
    Belahsen, Faouzi
    Pruessmann, Klaas
    Kollias, Spyros
    JOURNAL OF MEDICAL PHYSICS, 2009, 34 (01) : 37 - 42
  • [10] Simultaneous Multislice Echo Planar Imaging With Blipped Controlled Aliasing in Parallel Imaging Results in Higher Acceleration A Promising Technique for Accelerated Diffusion Tensor Imaging of Skeletal Muscle
    Filli, Lukas
    Piccirelli, Marco
    Kenkel, David
    Guggenberger, Roman
    Andreisek, Gustav
    Beck, Thomas
    Runge, Val M.
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2015, 50 (07) : 456 - 463