Monte carlo study on dose distributions around 192Ir, 169Yb, and 125I brachytherapy sources using EGSnrc-based egs_brachy user-code

被引:1
作者
Mishra, Subhalaxmi [1 ]
Mishra, Bibekananda [2 ]
Selvam, T. Palani [1 ,3 ]
Deshpande, Sudesh [4 ]
Pathan, Munir Shabbir [1 ]
Kumar, Rajesh [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Radiol Phys & Advisory, Hlth Safety & Environm Grp, Mumbai, Maharashtra, India
[2] Atom Energy Regulatory Board, Div Radiol Safety, Mumbai, Maharashtra, India
[3] Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
[4] PD Hinduja Natl Hosp & MRC, Dept Radiat Oncol, Mumbai, Maharashtra, India
关键词
Brachytherapy; egs_brachy; EGSnrc code system; Monte Carlo; TG-43; dosimetry; DOSIMETRY; IR-192; I-125; AAPM; RECOMMENDATIONS; CO-60; EYE;
D O I
10.4103/jmp.jmp_16_22
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction/: As per the recommendations of the American Association of Physicists in Medicine Task Group 43, Monte Carlo (MC) investigators should reproduce previously published dose distributions whenever new features of the code are explored. The purpose of the present study is to benchmark the TG-43 dosimetric parameters calculated using the new MC user-code egs_brachy of EGSnrc code system for three different radionuclides 192Ir, 169Yb, and 125I which represent high-, intermediate-, and low-energy sources, respectively. Materials and Methods: Brachytherapy sources investigated in this study are high-dose rate (HDR) 192Ir VariSource (Model VS2000), 169Yb HDR (Model 4140), and 125I -low-dose-rate (LDR) (Model OcuProsta). The TG-43 dosimetric parameters such as air-kerma strength, Sk, dose rate constant, Lambda, radial dose function, g(r) and anisotropy function, F(r,theta) and two-dimensional (2D) absorbed dose rate data (along-away table) are calculated in a cylindrical water phantom of mass density 0.998 g/cm3 using the MC code egs_brachy. Dimensions of phantom considered for 192Ir VS2000 and 169Yb sources are 80 cm diameter x80 cm height, whereas for 125I OcuProsta source, 30 cm diameter x30 cm height cylindrical water phantom is considered for MC calculations. Results: The dosimetric parameters calculated using egs_brachy are compared against the values published in the literature. The calculated values of dose rate constants from this study agree with the published values within statistical uncertainties for all investigated sources. Good agreement is found between the egs_brachy calculated radial dose functions, g(r), anisotropy functions, and 2D dose rate data with the published values (within 2%) for the same phantom dimensions. For 192Ir VS2000 source, difference of about 28% is observed in g(r) value at 18 cm from the source which is due to differences in the phantom dimensions. Conclusion: The study validates TG-43 dose parameters calculated using egs_brachy for 192Ir, 169Yb, and 125I brachytherapy sources with the values published in the literature.
引用
收藏
页码:270 / 278
页数:9
相关论文
共 32 条
  • [1] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    [J]. MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [2] ACCURATE MONTE-CARLO CALCULATIONS OF THE COMBINED ATTENUATION AND BUILDUP FACTORS, FOR ENERGIES (20-1500 KEV) AND DISTANCES (0-10 CM) RELEVANT IN BRACHYTHERAPY
    ANGELOPOULOS, A
    PERRIS, A
    SAKELLARIOU, K
    SAKELLIOU, L
    SARIGIANNIS, K
    ZARRIS, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (06) : 763 - 778
  • [3] [Anonymous], 1991, NUCL DATA SHEETS A 1
  • [4] Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation
    Beaulieu, Luc
    Tedgren, Asa Carlsson
    Carrier, Jean-Francois
    Davis, Stephen D.
    Mourtada, Firas
    Rivard, Mark J.
    Thomson, Rowan M.
    Verhaegen, Frank
    Wareing, Todd A.
    Williamson, Jeffrey F.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6208 - 6236
  • [5] Berger M.J., 1987, XCOM PHOTON CROSS SE
  • [6] Brown FB., 2003, MCNP A GEN M CARLO N
  • [7] egs_brachy: a versatile and fast Monte Carlo code for brachytherapy
    Chamberland, Marc J. P.
    Taylor, Randle E. P.
    Rogers, D. W. O.
    Thomson, Rowan M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23) : 8214 - 8231
  • [8] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 1975 - 1984
  • [9] Kawrakow I, 2013, PIRS701 NRCC
  • [10] Kawrakow I., 2009, PIRS898REVA NAT RES