The truncation artifact in a skinny patient following myocardial perfusion SPECT

被引:0
|
作者
Pirayesh, Elahe [1 ]
机构
[1] Shahid Beheshti Univ Med Sci, Dept Nucl Med, Shohada E Tajrish Med Ctr, Sch Med, Tehran, Iran
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2021年 / 29卷 / 01期
关键词
Artifacts; Myocardial perfusion imaging; SPECT; Truncation;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Myocardial perfusion SPECT is one of the most common imaging techniques performed in nuclear medicine departments. To avoid misleading interpretation, it is necessary to address the quality control and technical problems. The truncation artifact occurs when the patient size is large relative to the field of view of the camera, causing false perfusion defects in the LV myocardium, misinterpreted as myocardial perfusion abnormality. It usually happens in obese patients, who may deviate from the detector field. Here, we present a skinny patient showing myocardial truncation artifact, proved to be because of technical issues.
引用
收藏
页码:35 / 37
页数:3
相关论文
共 50 条
  • [21] Quantification of Myocardial Perfusion: SPECT
    Petretta M.
    Cuocolo R.
    Acampa W.
    Cuocolo A.
    Current Cardiovascular Imaging Reports, 2012, 5 (3) : 144 - 150
  • [22] Assessment of myocardial perfusion reserve with dynamic myocardial perfusion SPECT
    Ben-Haim, Simona
    Baavour, Rafael
    Haroon, Athar
    Allie, Rayjanah
    Sitek, Arkadiusz
    Scouler, Andrew
    Erlandsson, Kjell
    Saad, Ziauddin Zia
    Breault, Christopher
    Bomanji, Jamshed
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [23] Quantitative myocardial perfusion SPECT
    Benjamin M. W. Tsui
    Eric C. Frey
    Karen J. LaCroix
    David S. Lalush
    William H. McCartney
    Michael A. King
    Grant T. Gullberg
    Journal of Nuclear Cardiology, 1998, 5 : 507 - 522
  • [24] Quantitative myocardial perfusion SPECT
    Tsui, BMW
    Frey, EC
    LaCroix, KJ
    Lalush, DS
    McCartney, WH
    King, MA
    Gullberg, GT
    JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (05) : 507 - 522
  • [25] The impact of gated SPECT on rate of early referral to catheterization following myocardial perfusion SPECT.
    Lewin, H
    Hachamovitch, R
    Germano, G
    Friedman, J
    Cohen, I
    Kang, X
    Berman, D
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 87P - 87P
  • [26] Which patient-detector distance to avoid partial non-visualization of cardiac activity in myocardial perfusion SPECT of skinny patients?: A cardiac phantom study
    Yapici, O.
    Aydin, M.
    Basoglu, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S261 - S261
  • [27] The radiation exposure to the patient caused by the transmission measurement for myocardial perfusion SPECT
    Seifert, H
    Chapot, C
    Schaefer, A
    Donsch, P
    Kirsch, CM
    NUKLEARMEDIZIN, 1999, 38 (06) : 186 - 188
  • [28] Rotating and stationary SPECT system patient motion myocardial perfusion artifacts
    Kenneth J. Nichols
    Andrew Van Tosh
    Journal of Nuclear Cardiology, 2019, 26 : 1323 - 1326
  • [29] Rotating and stationary SPECT system patient motion myocardial perfusion artifacts
    Nichols, Kenneth J.
    Van Tosh, Andrew
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (04) : 1323 - 1326
  • [30] TRUNCATION ARTIFACT REDUCTION IN TRANSMISSION CT FOR IMPROVED SPECT ATTENUATION COMPENSATION
    KADRMAS, DJ
    JASZCZAK, RJ
    MCCORMICK, JW
    COLEMAN, RE
    LIM, CB
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06): : 1085 - 1104