Determination of plasma and urinary angiotensinogen levels in rodents by newly developed ELISA

被引:57
|
作者
Kobori, Hiroyuki [1 ,2 ]
Katsurada, Akemi [1 ,2 ]
Miyata, Kayoko [1 ,2 ]
Ohashi, Naro [1 ,2 ]
Satou, Ryousuke [1 ,2 ]
Saito, Toshie [1 ,2 ]
Hagiwara, Yoshiaki [3 ]
Miyashita, Kazuya [3 ]
Navar, L. Gabriel [1 ,2 ]
机构
[1] Tulane Univ, Hlth Sci Ctr, Dept Physiol & Hypertens, New Orleans, LA 70112 USA
[2] Tulane Univ, Hlth Sci Ctr, Renal Ctr Excellence, New Orleans, LA 70112 USA
[3] Immunobiol Labs, Gunma, Japan
关键词
enzyme-linked immunosorbent assay; renin-angiotensin system; plasma; urine; mouse; rat;
D O I
10.1152/ajprenal.00588.2007
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We recently reported that urinary excretion rates of angiotensinogen provide a specific index of the intrarenal renin-angiotensin system status in angiotensin II-dependent hypertensive rats. Angiotensinogen concentrations in mouse plasma are thought to be much lower than those in rat plasma; however, detailed information is deficient due to lack of direct quantitative measurements of rodent angiotensinogen. To elucidate this issue, we have developed a quantitative method for measurement of rodent angiotensinogen using a sandwich-type ELISA. The standard curve for mouse and rat angiotensinogen exhibited a high linearity at 0.16-10 and 0.08-5 ng/ml, respectively, with correlation coefficients >0.99. While plasma angiotensinogen concentrations of male high serum IgA (HIGA) mice (IgA nephritis model animals, 1,308 +/- 47 ng/ml; n = 10) were lower than those of control BALB/c mice (1,620 +/- 384; n = 12), urinary angiotensinogen concentrations of HIGA mice (14.6 +/- 1.5 ng/ ml; n = 34) were higher than those of BALB/c mice (4.6 +/- 0.1; n = 2). In a similar manner, while plasma angiotensinogen concentrations of Zucker diabetic fatty (ZDF) obese rats (type 2 diabetic model animals, 1,789 +/- 50 ng/ ml; n = 5) were lower than those of control ZDF lean rats (2,296 +/- 47; n = 5), urinary angiotensinogen concentrations of ZDF obese rats (88.2 +/- 11.4 ng/ ml; n = 15) were higher than those of ZDF lean rats (31.3 +/- 1.9; n = 15). These data indicate that plasma and urinary angiotensinogen concentrations are less in mice than rats. However, these data suggest that urinary angiotensinogen levels are different from plasma angiotensinogen levels in rodents. The development of rodent angiotensinogen ELISA allows quantitative comparisons in mouse and rat angiotensinogen levels in models of hypertension and cardiovascular and kidney diseases.
引用
收藏
页码:F1257 / F1263
页数:7
相关论文
共 50 条
  • [21] Determination of cefadroxil in rat plasma and urine using LC-MS/MS and its application to pharmacokinetic and urinary excretion studies
    Jin, Hyo-Eon
    Kim, In-Bong
    Kim, Yu Chul
    Cho, Kwan Hyung
    Maeng, Han-Joo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 103 - 110
  • [22] Pomegranate juice and extracts provide similar levels of plasma and urinary ellagitannin metabolites in human subjects
    Seeram, Navindra P.
    Zhang, Yanjun
    McKeever, Rodney
    Henning, Susanne M.
    Lee, Ru-po
    Suchard, Marc A.
    Li, Zhaoping
    Chen, Steve
    Thames, Gail
    Zerlin, Alona
    Nguyen, Martha
    Wang, David
    Dreher, Mark
    Heber, David
    JOURNAL OF MEDICINAL FOOD, 2008, 11 (02) : 390 - 394
  • [23] Effect of levels of feed intake on plasma concentration and urinary excretion of purine derivatives in crossbred bulls
    George, S. K.
    Dipu, M. T.
    Mehra, U. R.
    Verma, A. K.
    Singh, P.
    JOURNAL OF ANIMAL AND FEED SCIENCES, 2007, 16 (01): : 26 - 36
  • [24] Urinary excretion and plasma vitamin E levels in patients with AIDS
    Jordao, AA
    Silveira, S
    Figueiredo, JFD
    Vannucchi, H
    NUTRITION, 1998, 14 (05) : 423 - 426
  • [25] Newly developed radioimmunoassay for Human Angiotensin-(1-12) measurements in plasma and urine
    Ahmad, Sarfaraz
    Punzi, Henry A.
    Wright, Kendra N.
    Groban, Leanne
    Ferrario, Carlos M.
    MOLECULAR AND CELLULAR ENDOCRINOLOGY, 2021, 529
  • [26] Determination of urinary iodine by inductively coupled plasma mass spectrometry
    Macours, P.
    Aubry, J. C.
    Hauquier, B.
    Boeynaems, J. M.
    Goldman, S.
    Moreno-Reyes, R.
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2008, 22 (02) : 162 - 165
  • [27] Lack of influence of dietary nitrate/nitrite on plasma nitrotyrosine levels measured using a competitive inhibition of binding ELISA assay
    Oldreive, C
    Bradley, N
    Bruckdorfer, R
    Rice-Evans, C
    FREE RADICAL RESEARCH, 2001, 35 (04) : 377 - 386
  • [28] Studies on neurosteroids XIV. Levels of dehydroepiandrosterone sulfate in rat brain and serum determined with newly developed enzyme-linked immunosorbent assay
    Higashi, T
    Daifu, Y
    Shimada, K
    STEROIDS, 2001, 66 (12) : 865 - 874
  • [29] D-dimer plasma levels during normal pregnancy measured by specific ELISA
    Francalanci, I
    Comeglio, P
    Liotta, AA
    Cellai, AP
    Fedi, S
    Parretti, E
    Mecacci, F
    Mello, G
    Prisco, D
    Abbate, R
    INTERNATIONAL JOURNAL OF CLINICAL & LABORATORY RESEARCH, 1997, 27 (01): : 65 - 67
  • [30] Relationship between plasma, saliva, urinary and faecal cortisol levels in pigs
    Mohan, N. H.
    Nath, Ankit
    Thomas, R.
    Kumar, S.
    Banik, S.
    Das, A. K.
    Das, R. K.
    Sarma, D. K.
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2020, 90 (05): : 768 - 772