Determination of plasma and urinary angiotensinogen levels in rodents by newly developed ELISA

被引:57
|
作者
Kobori, Hiroyuki [1 ,2 ]
Katsurada, Akemi [1 ,2 ]
Miyata, Kayoko [1 ,2 ]
Ohashi, Naro [1 ,2 ]
Satou, Ryousuke [1 ,2 ]
Saito, Toshie [1 ,2 ]
Hagiwara, Yoshiaki [3 ]
Miyashita, Kazuya [3 ]
Navar, L. Gabriel [1 ,2 ]
机构
[1] Tulane Univ, Hlth Sci Ctr, Dept Physiol & Hypertens, New Orleans, LA 70112 USA
[2] Tulane Univ, Hlth Sci Ctr, Renal Ctr Excellence, New Orleans, LA 70112 USA
[3] Immunobiol Labs, Gunma, Japan
关键词
enzyme-linked immunosorbent assay; renin-angiotensin system; plasma; urine; mouse; rat;
D O I
10.1152/ajprenal.00588.2007
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We recently reported that urinary excretion rates of angiotensinogen provide a specific index of the intrarenal renin-angiotensin system status in angiotensin II-dependent hypertensive rats. Angiotensinogen concentrations in mouse plasma are thought to be much lower than those in rat plasma; however, detailed information is deficient due to lack of direct quantitative measurements of rodent angiotensinogen. To elucidate this issue, we have developed a quantitative method for measurement of rodent angiotensinogen using a sandwich-type ELISA. The standard curve for mouse and rat angiotensinogen exhibited a high linearity at 0.16-10 and 0.08-5 ng/ml, respectively, with correlation coefficients >0.99. While plasma angiotensinogen concentrations of male high serum IgA (HIGA) mice (IgA nephritis model animals, 1,308 +/- 47 ng/ml; n = 10) were lower than those of control BALB/c mice (1,620 +/- 384; n = 12), urinary angiotensinogen concentrations of HIGA mice (14.6 +/- 1.5 ng/ ml; n = 34) were higher than those of BALB/c mice (4.6 +/- 0.1; n = 2). In a similar manner, while plasma angiotensinogen concentrations of Zucker diabetic fatty (ZDF) obese rats (type 2 diabetic model animals, 1,789 +/- 50 ng/ ml; n = 5) were lower than those of control ZDF lean rats (2,296 +/- 47; n = 5), urinary angiotensinogen concentrations of ZDF obese rats (88.2 +/- 11.4 ng/ ml; n = 15) were higher than those of ZDF lean rats (31.3 +/- 1.9; n = 15). These data indicate that plasma and urinary angiotensinogen concentrations are less in mice than rats. However, these data suggest that urinary angiotensinogen levels are different from plasma angiotensinogen levels in rodents. The development of rodent angiotensinogen ELISA allows quantitative comparisons in mouse and rat angiotensinogen levels in models of hypertension and cardiovascular and kidney diseases.
引用
收藏
页码:F1257 / F1263
页数:7
相关论文
共 50 条
  • [1] Plasma pentosidine levels measured by a newly developed method using ELISA in patients with chronic renal failure
    Sanaka, T
    Funaki, T
    Tanaka, T
    Hoshi, S
    Niwayama, J
    Taitoh, T
    Nishimura, H
    Higuchi, C
    NEPHRON, 2002, 91 (01): : 64 - 73
  • [2] Determination of calreticulin in Japanese monkey tissues with a newly-developed ELISA system
    Higashino, Atsunori
    Yonezawa, Satoshi
    Kageyama, Takashi
    ZOOLOGICAL SCIENCE, 2006, 23 (12) : 1222 - 1222
  • [3] Determination of angiotensinogen in plasma.
    Maier, V
    Schilling, S
    CLINICAL CHEMISTRY, 2001, 47 (06) : A6 - A6
  • [4] MEASUREMENT OF HUMAN PHOSPHOLIPASE-A2 IN ARTHRITIS PLASMA USING A NEWLY DEVELOPED SANDWICH ELISA
    SMITH, GM
    WARD, RL
    MCGUIGAN, L
    RAJKOVIC, IA
    SCOTT, KF
    BRITISH JOURNAL OF RHEUMATOLOGY, 1992, 31 (03): : 175 - 178
  • [5] USE OF ELISA FOR DETERMINATION OF PLASMA PROLACTIN LEVELS IN THE HOUSE WREN
    SINTICH, SM
    KEAGLE, MK
    HARPER, RG
    WELSFORD, IG
    CONDOR, 1995, 97 (04): : 1057 - 1061
  • [6] Increased levels of citrullinated antithrombin in plasma of patients with rheumatoid arthritis and colorectal adenocarcinoma determined by a newly developed ELISA using a specific monoclonal antibody
    Ordonez, Adriana
    Yelamos, Jose
    Pedersen, Shona
    Minano, Antonia
    Conesa-Zamora, Pablo
    Kristensen, Soren R.
    Stender, Mogens T.
    Thorlacius-Ussing, Ole
    Martinez-Martinez, Irene
    Vicente, Vicente
    Corral, Javier
    THROMBOSIS AND HAEMOSTASIS, 2010, 104 (06) : 1143 - 1149
  • [7] Measurement of ITIH4 and Hp levels in bitches with pyometra using newly developed ELISA methods
    Soler, Lourdes
    Szczubial, Marek
    Dabrowski, Roman
    Plusa, Anna
    Bochniarz, Mariola
    Brodzki, Piotr
    Lampreave, Fermin
    Pineiro, Matilde
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2021, 235
  • [8] A newly developed glucagon sandwich ELISA is useful for more accurate glucagon evaluation than the currently used sandwich ELISA in subjects with elevated plasma proglucagon-derived peptide levels
    Kobayashi, Masaki
    Maruyama, Nobuhiro
    Yamamoto, Yukako
    Togawa, Takeshi
    Ida, Takanori
    Yoshida, Morikatsu
    Miyazato, Mikiya
    Kitada, Masahisa
    Hayashi, Yoshitaka
    Kashiwagi, Atsunori
    Kitamura, Tadahiro
    JOURNAL OF DIABETES INVESTIGATION, 2023, 14 (05) : 648 - 658
  • [9] PLASMA LEVELS INCREASED BY ANGIOTENSINOGEN IN MALIGNANT HYPERTENSION
    ROSSET, E
    SCHERRER, JR
    VEYRAT, R
    HELVETICA MEDICA ACTA, 1973, 36 (5-6): : 494 - 495
  • [10] ROLE OF RENIN IN REGULATION OF ANGIOTENSINOGEN LEVELS IN PLASMA
    TATEISHI, H
    NASJLETTI, A
    MASSON, GMC