Quantitation of HIV-1 RNA in dried blood spots by the real-time NucliSENS EasyQ HIV-1 assay in Senegal

被引:48
作者
Kane, Coumba Toure [1 ]
Ndiaye, Halimatou Diop [1 ]
Diallo, Sada [1 ]
Ndiaye, Ibrahima [1 ]
Wade, Abdoulaye Sidibe [2 ]
Diaw, Papa Alassane [1 ]
Gaye-Diallo, Aissatou [1 ]
Mboup, Souleymane [1 ]
机构
[1] Lab Bacteriol Virol CHU A Dantec, Dakar, Senegal
[2] Minist Hlth, Div AIDS IST, Dakar, Senegal
关键词
dried blood spot; HIV-1; RNA; real-time detection; developing countries;
D O I
10.1016/j.jviromet.2007.11.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of viral load in plasma remains the best marker for the follow-up of antiretroviral therapy. However, its use is limited in developing countries due to the lack of adequate facilities and equipment, and cryopreservation of plasma during storage and transportation. Practical and reliable methods adapted to field conditions for the collection, transportation and accurate measurement of HIV-1 viral load are needed for the optimum use of antiretroviral therapy in resource-limited countries. This study evaluated the use of dried blood spots (DBS) for the real-time quantitation of HIV-1 RNA levels with the NucliSENS EasyQ (R) HIV-1 assay (bioMerieux, Lyon, France) under field conditions in Senegal (Africa). Dried blood spots and plasma from 41 patients living in suburban Dakar were used for determination of HIV-1 RNA concentrations and stability at 37 degrees C. Analysis was performed at the Dakar University Hospital laboratory. Extraction was done with the bioMerieux NucliSENS (R) miniMAG (TM), and real-time detection was done with the bioMerieux NucliSENS (R) EasyQ system. HIV-1 RNA concentrations in plasma were compared with concentrations in dried blood spots after 8 and 15 days at 37 degrees C. The study showed a strong concordance in RNA levels between plasma and dried blood spots, which appear to be very stable over time with no apparent degradation observed after 2 weeks at 37 degrees C (mean difference 0.065 log IU/ml). These results suggest that the use of dried blood spots in combination with the NucliSENS EasyQ HIV-1 assay is well adapted for HIV-1 RNA level monitoring in centralized laboratories in developing countries. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 295
页数:5
相关论文
共 13 条
  • [1] High correlation of human immunodeficiency virus type-1 viral load measured in dried-blood spot samples and in plasma under different storage conditions
    Alvarez-Muñoz, MT
    Zaragoza-Rodríguez, S
    Rojas-Montes, O
    Palacios-Saucedo, G
    Vázquez-Rosales, G
    Gómez-Delgado, A
    Torres, J
    Muñoz, O
    [J]. ARCHIVES OF MEDICAL RESEARCH, 2005, 36 (04) : 382 - 386
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Multicenter evaluation of use of dried blood and plasma spot specimens in quantitative assays for human immunodeficiency virus RNA: Measurement, precision, and RNA stability
    Brambilla, D
    Jennings, C
    Aldrovandi, G
    Bremer, J
    Comeau, AM
    Cassol, SA
    Dickover, R
    Jackson, JB
    Pitt, J
    Sullivan, JL
    Butcher, A
    Grosso, L
    Reichelderfer, P
    Fiscus, SA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) : 1888 - 1893
  • [4] USE OF DRIED BLOOD SPOT SPECIMENS IN THE DETECTION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 BY THE POLYMERASE CHAIN-REACTION
    CASSOL, S
    SALAS, T
    ARELLA, M
    NEUMANN, P
    SCHECHTER, MT
    OSHAUGHNESSY, M
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (04) : 667 - 671
  • [5] Quantification of human immunodeficiency virus type 1 RNA from dried plasma spots collected on filter paper
    Cassol, S
    Gill, MJ
    Pilon, R
    Cormier, M
    Voigt, RF
    Willoughby, B
    Forbes, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (11) : 2795 - 2801
  • [6] Quantitation of human immunodeficiency virus type 1 RNA in plasma by using blood dried on filter paper
    Fiscus, SA
    Brambilla, D
    Grosso, L
    Schock, J
    Cronin, M
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (01) : 258 - 260
  • [7] LITTLE RR, 1985, CLIN CHEM, V30, P213
  • [8] DNA MICROEXTRACTION FROM DRIED BLOOD SPOTS ON FILTER-PAPER BLOTTERS - POTENTIAL APPLICATIONS TO NEWBORN SCREENING
    MCCABE, ERB
    HUANG, SZ
    SELTZER, WK
    LAW, ML
    [J]. HUMAN GENETICS, 1987, 75 (03) : 213 - 216
  • [9] Use of filter paper for the collection and analysis of human whole blood specimens
    Mei, JV
    Alexander, JR
    Adam, BW
    Hannon, WH
    [J]. JOURNAL OF NUTRITION, 2001, 131 (05) : 1631S - 1636S
  • [10] Use of dried whole blood spots to measure CD4+lymphocyte counts in HIV-1-infected patients
    Mwaba, P
    Cassol, S
    Pilon, R
    Chintu, C
    Janes, M
    Nunn, A
    Zumla, A
    [J]. LANCET, 2003, 362 (9394) : 1459 - 1460