A Crucial Wave Detection and Delineation Method for Twelve-Lead ECG Signals

被引:19
作者
Chen, Genlang [1 ,2 ]
Chen, Maolin [3 ]
Zhang, Jiajian [3 ]
Zhang, Liang [4 ]
Pang, Chaoyi [1 ,2 ]
机构
[1] Zhejiang Univ, Ningbo Inst Technol, Ningbo 315100, Peoples R China
[2] Zhejiang Univ, Ningbo Res Inst, Ningbo 315100, Peoples R China
[3] Zhejiang Univ, Coll Comp Sci & Technol, Hangzhou 310021, Peoples R China
[4] Ningbo Municipal Ctr Dis Control & Prevent, Ningbo 315100, Peoples R China
关键词
ECG; twelve-lead signals; local distance transform; detection; delineation; AUTOMATIC DETECTION; T-WAVES; QRS; ENHANCEMENT; STANDARDS; ALGORITHM; POINTS;
D O I
10.1109/ACCESS.2020.2965334
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Delineating the crucial waves in electrocardiogram records is a paramount work for the automatic diagnosis system of heart diseases. In this paper, a novel method is described to determine the boundaries and the peaks of P waves, QRS complexes and T waves by utilizing twelve-lead electrocardiogram signals. It avoids the difficulty of setting the thresholds when determining the boundaries of crucial waves and also the trouble of selection of wavelet basis as the wavelet-based method does. The signals are first preprocessed by a bandpass filter. After that, the locations of QRS complexes are identified. And based on the QRS locations, adaptive search windows are set to detect the locations of P waves and T waves. Then, a method called local distance transform decides the wave boundary in each lead. Finally, the final boundary determination rule is applied to obtain reliable boundaries. We justify the performance of our algorithm on LUDB database. When the tolerance window interval is 40ms, the peak accuracies of P wave, QRS complex and T wave are all beyond 98% and their boundary accuracies are all above 96%. Compared with the derivative threshold method and the wavelet-based method where the tolerance window interval is 150ms, the algorithm shows a sensitivity and a positive predictive value of peaks and boundaries greater than or equal to 98.43% and 96.44% for the P wave, 99.89% and 99.86% for the QRS complex and 99.21% and 99.85% for the T wave. For the critera of average error and standard deviation, our method has the performance similar to those methods. In addition, our algorithm can also handle such several situations where the boundary determination of crucial waves is tough as high T wave, high noise and baseline wandering well.
引用
收藏
页码:10707 / 10717
页数:11
相关论文
共 33 条
  • [1] ECG beat detection using filter banks
    Afonso, VX
    Tompkins, WJ
    Nguyen, TQ
    Luo, S
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (02) : 192 - 202
  • [2] ECG signal analysis through hidden Markov models
    Andreao, Rodrigo V.
    Dorizzi, Bernadette
    Boudy, Jerome
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (08) : 1541 - 1549
  • [3] [Anonymous], [No title captured]
  • [4] [Anonymous], [No title captured]
  • [5] [Anonymous], [No title captured]
  • [6] [Anonymous], [No title captured]
  • [7] [Anonymous], [No title captured]
  • [8] Cao X., 2001, CHINESE J MED PHYS, V18, P46, DOI [10.3969/j.issn.1005-202X.2001.01.021, DOI 10.3969/J.ISSN.1005-202X.2001.01.021]
  • [9] ECG Signal Compression Using Adaptive Hermite Functions
    Dozsa, Tamas
    Kovacs, Peter
    [J]. ICT INNOVATIONS 2015: EMERGING TECHNOLOGIES FOR BETTER LIVING, 2016, 399 : 245 - 254
  • [10] Arrhythmia recognition and classification using combined linear and nonlinear features of ECG signals
    Elhaj, Fatin A.
    Salim, Naomie
    Harris, Arief R.
    Swee, Tan Tian
    Ahmed, Taquia
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2016, 127 : 52 - 63