Differentiation Between Benign and Metastatic Breast Lymph Nodes Using Apparent Diffusion Coefficients

被引:8
|
作者
Fardanesh, Reza [1 ]
Thakur, Sunitha B. [1 ,2 ]
Sevilimedu, Varadan [3 ]
Horvat, Joao V. [1 ]
Gullo, Roberto Lo [1 ]
Reiner, Jeffrey S. [1 ]
Eskreis-Winkler, Sarah [1 ]
Thakur, Nikita [1 ,4 ]
Pinker, Katja [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Epidemiol & Biostat, 1275 York Ave, New York, NY 10021 USA
[4] Touro Coll Osteopath Med, Middletown, NY USA
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
基金
美国国家卫生研究院;
关键词
breast cancer; prognostic factors; lymph nodes; diffusion-weighted imaging; apparent diffusion coefficient; MRI; DIAGNOSTIC-ACCURACY; FROZEN-SECTION; WEIGHTED MRI; INTRAOPERATIVE EVALUATION; IMAGING IMPROVES; IMPRINT CYTOLOGY; CANCER; BIOPSY; MAMMOGRAPHY; PERFORMANCE;
D O I
10.3389/fonc.2022.795265
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study was to determine the range of apparent diffusion coefficient (ADC) values for benign axillary lymph nodes in contrast to malignant axillary lymph nodes, and to define the optimal ADC thresholds for three different ADC parameters (minimum, maximum, and mean ADC) in differentiating between benign and malignant lymph nodes. This retrospective study included consecutive patients who underwent breast MRI from January 2017-December 2020. Two-year follow-up breast imaging or histopathology served as the reference standard for axillary lymph node status. Area under the receiver operating characteristic curve (AUC) values for minimum, maximum, and mean ADC (min ADC, max ADC, and mean ADC) for benign vs malignant axillary lymph nodes were determined using the Wilcoxon rank sum test, and optimal ADC thresholds were determined using Youden's Index. The final study sample consisted of 217 patients (100% female, median age of 52 years (range, 22-81), 110 with benign axillary lymph nodes and 107 with malignant axillary lymph nodes. For benign axillary lymph nodes, ADC values (x10(-3) mm(2)/s) ranged from 0.522-2.712 for mean ADC, 0.774-3.382 for max ADC, and 0.071-2.409 for min ADC; for malignant axillary lymph nodes, ADC values (x10(-3) mm(2)/s) ranged from 0.796-1.080 for mean ADC, 1.168-1.592 for max ADC, and 0.351-0.688 for min ADC for malignant axillary lymph nodes. While there was a statistically difference in all ADC parameters (p<0.001) between benign and malignant axillary lymph nodes, boxplots illustrate overlaps in ADC values, with the least overlap occurring with mean ADC, suggesting that this is the most useful ADC parameter for differentiating between benign and malignant axillary lymph nodes. The mean ADC threshold that resulted in the highest diagnostic accuracy for differentiating between benign and malignant lymph nodes was 1.004x10(-3) mm(2)/s, yielding an accuracy of 75%, sensitivity of 71%, specificity of 79%, positive predictive value of 77%, and negative predictive value of 74%. This mean ADC threshold is lower than the European Society of Breast Imaging (EUSOBI) mean ADC threshold of 1.300x10(-3) mm(2)/s, therefore suggesting that the EUSOBI threshold which was recently recommended for breast tumors should not be extrapolated to evaluate the axillary lymph nodes.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Correlations between apparent diffusion coefficient values and histopathology classification of breast invasive ductal carcinoma
    Zhang, Wei
    Jin, Guanqiao
    Liu, Junjie
    Huang, Xiangyang
    Kang, Wei
    Xie, Dong
    Luo, Ningbin
    Su, Danke
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 3111 - 3117
  • [42] Diffusion-Weighted Imaging of Breast Masses: Comparison of Diagnostic Performance Using Various Apparent Diffusion Coefficient Parameters
    Hirano, Maki
    Satake, Hiroko
    Ishigaki, Satoko
    Ikeda, Mitsuru
    Kawai, Hisashi
    Naganawa, Shinji
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (03) : 717 - 722
  • [43] Discrimination of Malignant versus Benign Mediastinal Lymph Nodes Using Diffusion MRI with an IVIM Model
    Qi, Li-Ping
    Yan, Wan-Pu
    Chen, Ke-Neng
    Zhong, Zheng
    Li, Xiao-Ting
    Cai, Kejia
    Sun, Ying-Shi
    Zhou, Xiaohong Joe
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1301 - 1309
  • [44] Discrimination of Malignant versus Benign Mediastinal Lymph Nodes Using Diffusion MRI with an IVIM Model
    Li-Ping Qi
    Wan-Pu Yan
    Ke-Neng Chen
    Zheng Zhong
    Xiao-Ting Li
    Kejia Cai
    Ying-Shi Sun
    Xiaohong Joe Zhou
    European Radiology, 2018, 28 : 1301 - 1309
  • [45] Diffusion-weighted imaging in oral squamous cell carcinoma using 3 Tesla MRI: is there a chance for preoperative discrimination between benign and malignant lymph nodes in daily clinical routine?
    Wendl, Christina M.
    Mueller, Steffen
    Eiglsperger, Johannes
    Fellner, Claudia
    Jung, Ernst M.
    Meier, Johannes K.
    ACTA RADIOLOGICA, 2016, 57 (08) : 939 - 946
  • [46] Qualitative Classification of Shear Wave Elastography for Differential Diagnosis Between Benign and Metastatic Axillary Lymph Nodes in Breast Cancer
    Luo, Shuyi
    Yao, Guangyu
    Hong, Zhe
    Zhang, Shiyu
    Wang, Weizhen
    Zhang, Jingwen
    Zhang, Yaru
    Wu, Junkai
    Zhang, Li
    Cheng, Hong
    Hao, Yi
    Li, Yingjia
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [47] Comparison of four MRI diffusion models to differentiate benign from metastatic retropharyngeal lymph nodes
    Jun Liu
    Li Hua
    Fei Wang
    Ming Chen
    Yinan Sun
    Zhi Hu
    Luqing Shu
    Andong He
    Mengxiao Liu
    Qing Yang
    Juan Zhu
    Yinfeng Qian
    European Radiology Experimental, 9 (1)
  • [48] Diffusion-Weighted MRI: Association Between Patient Characteristics and Apparent Diffusion Coefficients of Normal Breast Fibroglandular Tissue at 3 T
    McDonald, Elizabeth S.
    Schopp, Jennifer G.
    Peacock, Sue
    DeMartini, Wendy D.
    Rahbar, Habib
    Lehman, Constance D.
    Partridge, Savannah C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (05) : W496 - W502
  • [49] Apparent diffusion coefficient for discriminating metastatic lymph nodes in patients with squamous cell carcinoma of the head and neck
    Pekcevik, Yeliz
    Cukurova, Ibrahim
    Arslan, Ilker Burak
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2015, 21 (05) : 397 - 402
  • [50] Discrimination between benign and malignant testicular lesions using volumetric apparent diffusion coefficient histogram analysis
    Fan, Chanyuan
    Min, Xiangde
    Feng, Zhaoyan
    Cai, Wei
    Li, Basen
    Zhang, Peipei
    You, Huijuan
    Xie, Jinke
    Wang, Liang
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126