Evaluation of integrated respiratory gating systems on a Novalis Tx system

被引:34
作者
Chang, Zheng [1 ]
Liu, TongHai [2 ]
Cai, Jing
Chen, Qing
Wang, Zhiheng
Yin, Fang-Fang
机构
[1] Duke Univ, Dept Radiat Oncol, Med Ctr, Durham, NC 27710 USA
[2] Shandong Canc Hosp & Inst, Dept Radiat Oncol, Jinan 250117, Shandong, Peoples R China
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2011年 / 12卷 / 03期
关键词
respiratory gating system; ExacTrac; RPM; Novalis Tx system; TUMOR MOTION; DELIVERY;
D O I
10.1120/jacmp.v12i3.3495
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the accuracy of motion tracking and radiation delivery control of integrated gating systems on a Novalis Tx system. The study was performed on a Novalis Tx system, which is equipped with Varian Real-time Position Management (RPM) system, and BrainLAB ExacTrac gating systems. In this study, the two systems were assessed on accuracy of both motion tracking and radiation delivery control. To evaluate motion tracking, two artificial motion profiles and five patients' respiratory profiles were used. The motion trajectories acquired by the two gating systems were compared against the references. To assess radiation delivery control, time delays were measured using a single-exposure method. More specifically, radiation is delivered with a 4 mm diameter cone within the phase range of 10%-45% for the BrainLAB ExacTrac system, and within the phase range of 0%-25% for the Varian RPM system during expiration, each for three times. Radiochromic films were used to record the radiation exposures and to calculate the time delays. In the work, the discrepancies were quantified using the parameters of mean and standard deviation (SD). Pearson's product-moment correlational analysis was used to test correlation of the data, which is quantified using a parameter of r. The trajectory profiles acquired by the gating systems show good agreement with those reference profiles. A quantitative analysis shows that the average mean discrepancies between BrainLAB ExacTrac system and known references are 1.5 mm and 1.9 mm for artificial and patient profiles, with the maximum motion amplitude of 28.0 mm. As for the Varian RPM system, the corresponding average mean discrepancies are 1.1 mm and 1.7 mm for artificial and patient profiles. With the proposed single-exposure method, the time delays are found to be 0.20 +/- 0.03 seconds and 0.09 +/- 0.01 seconds for BrainLAB ExacTrac and Varian RPM systems, respectively. The results indicate the systems can track motion and control radiation delivery with reasonable accuracy. The proposed single-exposure method has been demonstrated to be feasible in measuring time delay efficiently.
引用
收藏
页码:71 / 79
页数:9
相关论文
共 15 条
  • [1] [Anonymous], 1993, J ICRU
  • [2] A margin model to account for respiration-induced tumour motion and its variability
    Coolens, Catherine
    Webb, Steve
    Shirato, H.
    Nishioka, K.
    Evans, Phil M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (16) : 4317 - 4330
  • [3] An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT
    Hugo, GD
    Agazaryan, N
    Solberg, TD
    [J]. MEDICAL PHYSICS, 2002, 29 (11) : 2517 - 2525
  • [4] Technical aspects of image-guided respiration-gated radiation therapy
    Jiang, SB
    [J]. MEDICAL DOSIMETRY, 2006, 31 (02) : 141 - 151
  • [5] Time delay measurement for linac based treatment delivery in synchronized respiratory gating radiotherapy
    Jin, JY
    Yin, FF
    [J]. MEDICAL PHYSICS, 2005, 32 (05) : 1293 - 1296
  • [6] The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    Keall, Paul J.
    Mageras, Gig S.
    Balter, James M.
    Emery, Richard S.
    Forster, Kenneth M.
    Jiang, Steve B.
    Kapatoes, Jeffrey M.
    Low, Daniel A.
    Murphy, Martin J.
    Murray, Brad R.
    Ramsey, Chester R.
    Van Herk, Marcel B.
    Vedam, S. Sastry
    Wong, John W.
    Yorke, Ellen
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3874 - 3900
  • [7] Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system
    Li, XA
    Stepaniak, C
    Gore, E
    [J]. MEDICAL PHYSICS, 2006, 33 (01) : 145 - 154
  • [8] A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing
    Low, DA
    Nystrom, M
    Kalinin, E
    Parikh, P
    Dempsey, JF
    Bradley, JD
    Mutic, S
    Wahab, SH
    Islam, T
    Christensen, G
    Politte, DG
    Whiting, BR
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1254 - 1263
  • [9] Intrafractional tumor motion: Lung and liver
    Shirato, H
    Seppenwoolde, Y
    Kitamura, K
    Onimura, R
    Shimizu, S
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 10 - 18
  • [10] Time delays and margins in gated radiotherapy
    Smith, Wendy L.