Oscillometric and Intra-arterial Blood Pressure in Preterm and Term Infants: Extent of Discrepancy and Factors Associated with Inaccuracy

被引:16
|
作者
Shimokaze, Tomoyuki [1 ]
Akaba, Kazuhiro [1 ]
Saito, Emi [1 ]
机构
[1] Saiseikai Yamagata Hosp, Dept Pediat, Yamagata 9908545, Japan
关键词
noninvasive blood pressure; arterial line; discomfort; sedation; light-for-gestational-age; BIRTH-WEIGHT; ARTERIAL-PRESSURE; AGREEMENT; ACCURACY; MONITOR;
D O I
10.1055/s-0034-1383851
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Securing an arterial line to monitor continuous blood pressure (BP) is difficult in infants. We aimed to reveal the extent of discrepancies between oscillometric and direct BP. Study Design Infants who required continuous BP monitoring were prospectively enrolled. Direct and indirect BP were simultaneously recorded. Disposable BP cuffs matching one-half to two-thirds of the upper arm circumference were used. Results A total of 74 infants were studied (gestational age [GA], 24-42 weeks). The correlation coefficients of systolic, diastolic, and mean arterial BP of indirect and direct measurements were 0.87, 0.82, and 0.84, respectively (p < 0.001). The mean differences in systolic, diastolic, and mean arterial BP (indirect minus direct BP) were 2.2 +/- 5.7, - 6.0 +/- 5.8, and - 1.3 +/- 5.7 mm Hg, respectively. Oscillometric measurements significantly underestimated systolic BP in light-for-gestational-age infants and diastolic BP in infants without fentanyl administration. There were no significant correlations between discrepant BP measurements and edema, vasopressor administration, arterial line location, GA, postnatal age, body weight, pulse rate, or hemoglobin level. In 4.1% of infants, systolic BP increased by 10 to 15 mm Hg at the time of cuff expansion. Conclusion We recommend intra-arterial BP measurement when the BP values seriously influence the therapeutic protocol.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 31 条
  • [1] Comparison between oscillometric and intra-arterial blood pressure measurements in ill preterm and full-term neonates
    Lalan, Shwetal
    Blowey, Douglas
    JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2014, 8 (01) : 36 - 44
  • [2] Comparing Intra-Arterial, Auscultatory, and Oscillometric Measurement Methods for Arterial Blood Pressure
    Babadag, Keziban
    Zaybak, Ayten
    FLORENCE NIGHTINGALE JOURNAL OF NURSING, 2021, 29 (02): : 194 - 202
  • [3] Oscillometric and intra-arterial blood pressure in children post-kidney transplantation: Is invasive blood pressure measurement always needed?
    Marouane, Abderrahim
    Cornelissen, Elisabeth A. M.
    Nusmeier, Anneliese
    Bootsma-Robroeks, Charlotte M. H. H. T.
    PEDIATRIC TRANSPLANTATION, 2019, 23 (01)
  • [4] Comparison of Non-Invasive Oscillometric and Intra-Arterial Blood Pressure Measurements in Children Admitted to the Pediatric Intensive Care Unit
    Kaur, Jaswinder
    Bhargava, Siddharth
    Pooni, Puneet Aulakh
    Bhat, Deepak
    Dhooria, Gurdeep S.
    Arora, Kamaldeep
    Kakkar, Shruti
    Gill, Karambir
    JOURNAL OF PEDIATRIC INTENSIVE CARE, 2024, 13 (02) : 155 - 161
  • [5] Comparing oscillometric noninvasive and invasive intra-arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study
    Fujii, Tasuku
    Nishiwaki, Kimitoshi
    PEDIATRIC ANESTHESIA, 2020, 30 (12) : 1396 - 1401
  • [6] The agreement between oscillometric and intra-arterial technique for blood pressure monitoring in the lower extremities for infants and toddlers undergoing aortic coarctation repair
    Peng, Zhe-Zhe
    Zhang, Ma-Zhong
    Sun, Ying
    Bai, Jie
    Gu, Hong-Bin
    Liu, Pei-Pei
    Li, Min
    Cai, Mei-Hua
    PEDIATRIC ANESTHESIA, 2016, 26 (11) : 1091 - 1096
  • [7] Evaluation of the oscillometric method for noninvasive blood pressure measurement during cuff deflation and cuff inflation with reference to intra-arterial blood pressure
    Celler, Branko G.
    Yong, Andy
    Rubenis, Imants
    Butlin, Mark
    Argha, Ahmadreza
    Rehan, Rajan
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2024, 42 (07) : 1235 - 1247
  • [8] Continuous intra-arterial versus intermittent oscillometric arterial pressure monitoring and hypotension during induction of anaesthesia: the AWAKE randomised trial
    Kouz, Karim
    Wegge, Mirja
    Flick, Moritz
    Bergholz, Alina
    Moll-Khosrawi, Parisa
    Nitzschke, Rainer
    Trepte, Constantin J. C.
    Krause, Linda
    Sessler, Daniel I.
    Zollner, Christian
    Saugel, Bernd
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 129 (04) : 478 - 486
  • [9] Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement
    Harju, Jarkko
    Vehkaoja, Antti
    Kumpulainen, Pekka
    Campadello, Stefano
    Lindroos, Ville
    Yli-Hankala, Arvi
    Oksala, Niku
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (01) : 13 - 22
  • [10] A Comparison of Non-Invasive Blood Pressure Measurement Strategies with Intra-Arterial Measurement
    Rebesco, Matthew R.
    Pinkston, M. Cornelia
    Smyrnios, Nicholas A.
    Weisberg, Stacy N.
    PREHOSPITAL AND DISASTER MEDICINE, 2020, 35 (05) : 516 - 523