Correlations between central corneal power, axial length, anterior chamber depth and central corneal thickness of near-emmetropic young university students in Palestine

被引:0
|
作者
Aljarousha, Mohammed [1 ,2 ]
Daqa, Ansam A. [2 ]
Qanan, Fatma [2 ]
Murtaja, Haya [2 ]
Baraka, Nadeen [2 ]
机构
[1] Int Islamic Univ Malaysia, Fac Allied Hlth Sci, Dept Optometry & Visual Sci, Kuantan, Malaysia
[2] Islamic Univ Gaza, Fac Hlth Sci, Dept Optometry, Gaza, Palestine
来源
AFRICAN VISION AND EYE HEALTH JOURNAL | 2021年 / 80卷 / 01期
关键词
central corneal power; axial length; anterior chamber depth; ultrasonic pachymeter; automated refractometer-keratometer; corneal topography; Islamic University-Gaza; central corneal thickness; REFRACTIVE ERROR; CURVATURE; SHAPE; EYE;
D O I
10.4102/aveh.v80i1.571
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Researchers have found that the refractive states of the eye are influenced by a variety of variables. Aim: This study investigated the correlation between the central corneal power (CCP) and a number of variables, which include axial length (AL), anterior chamber depth (ACD) and the central corneal thickness (CCT) in near-emmetropic eyes of students. Setting: The study was conducted in the Optometry Laboratory of the Islamic University-Gaza (IUG), Palestine. Methods: In a prospective analysis, 200 near-emmetropic students were examined from February 2019 to May 2019 with an ultrasound scanner (A-scan), ultrasonic pachymeter and Visionix L79 automated refractometer Keratometer (ARK). Only the data of one eye were randomly chosen for investigation. Results: The means and standard deviations (s.d.) of the CCP, AL, ACD and CCT for male students (n = 97) were 43.19 dioptre (D) +/- 1.34 D, 23.54 mm +/- 0.68 mm, 3.59 mm +/- 0.26 mm and 549 mu m +/- 33 mu m, respectively. Furthermore, the means +/- s.d. of 103 female students were as follows: CCP 43.85 D +/- 1.43 D, AL 22.94 mm +/- 0.69 mm, ACD 3.35 mm +/- 0.25 mm and CCT 543 mu m +/- 35 mu m. There was a significant association between CCP and gender (p = 0.00). There was a negative significant correlation between CCP and AL for both the male (r = -0.64; p = 0.00) and the female (r = -0.71, p = 0.00) participants. Conclusion: This study provided information on CCP, AL, ACD and CCT in near-emmetropic eyes of adults. In male students, CCP was flatter and AL was longer when compared with female Palestinian students.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 18 条
  • [1] Relationship Between Central Corneal Thickness, Refractive Error, Corneal Curvature, Anterior Chamber Depth and Axial Length
    Chen, Mei-Ju
    Liu, Yin-Tzu
    Tsai, Chia-Chen
    Chen, Yen-Cheng
    Chou, Ching-Kuang
    Lee, Shu-Mei
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2009, 72 (03) : 133 - 137
  • [2] Central corneal thickness is not related to anterior scleral thickness or axial length
    Oliveira, Cristiano
    Tello, Celso
    Liebmann, Jeffrey
    Ritch, Robert
    JOURNAL OF GLAUCOMA, 2006, 15 (03) : 190 - 194
  • [3] Change in central corneal thickness, corneal endothelial cell density, anterior chamber depth and axial length after repair of rhegmatogenous retinal detachment
    Mukhtar, Ahsan
    Mehboob, Mohammad Asim
    Babar, Zaheer Uddin
    Ishaq, Mazhar
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (06) : 1412 - 1417
  • [4] Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry
    Fatih Özcura
    Sayime Aydın
    Nevin Uzgören
    Japanese Journal of Ophthalmology, 2008, 52 : 353 - 356
  • [5] Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry
    Oezcura, Fatih
    Aydin, Sayime
    Uzgoeren, Nevin
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2008, 52 (05) : 353 - 356
  • [6] Comparison of Anterior Chamber Depth and Central Corneal Thickness Measured Using Different Devices
    Jeung, Jae Gyun
    Gil, Tae Young
    Bae, Gi Hyun
    Shin, Seong Joo
    Chung, Sung Kun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1570 - 1576
  • [7] Association Between Central Corneal Thickness and Axial Length in Patients with Refractive Anomalies and Emmetropes
    Ismaili, Mimoza
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2023, 13 (03) : 96 - 100
  • [8] Central corneal thickness, axial length, anterior chamber and optic disc structure in patients with central and branch retinal vein occlusion
    Vural, Gozde Sahin
    Karahan, Eyyup
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 1077 - 1083
  • [9] Comparison of Central Corneal Thickness, Thinnest Corneal Thickness, Anterior Chamber Depth, and Simulated Keratometry Using Galilei, Pentacam, and Sirius Devices
    Anayol, Mustafa A.
    Guler, Emre
    Yagci, Ramazan
    Sekeroglu, Mehmet A.
    Yilmazoglu, Meltem
    Tirhis, Hakan
    Kulak, Ali E.
    Yilmazbas, Pelin
    CORNEA, 2014, 33 (06) : 582 - 586
  • [10] Changes in axial length, central cornea thickness, and anterior chamber depth after rhegmatogenous retinal detachment repair
    Huang, Chunmei
    Zhang, Tonghe
    Liu, Jian
    Ji, Qiang
    Tan, Ruili
    BMC OPHTHALMOLOGY, 2016, 16