Validity and Reliability of a Novel Smartphone Tele-Assessment Solution for Quantifying Hip Range of Motion

被引:7
作者
Marshall, Charlotte J. [1 ]
El-Ansary, Doa [1 ,2 ]
Pranata, Adrian [1 ]
Ganderton, Charlotte [1 ]
O'Donnell, John [3 ]
Takla, Amir [3 ]
Tran, Phong [1 ,2 ,4 ]
Wickramasinghe, Nilmini [1 ]
Tirosh, Oren [1 ,4 ]
机构
[1] Swinburne Univ Technol, Sch Hlth Sci, Hawthorn, Vic 3122, Australia
[2] Univ Melbourne, Sch Med, Dept Surg, Parkville, Vic 3052, Australia
[3] Hip Arthroscopy Australia, Richmond, Vic 3121, Australia
[4] Footscray Hosp, Dept Orthopaed Surg, Western Hlth, Footscray, Vic 3011, Australia
关键词
tele-assessment; smartphone; hip range of motion; FEMOROACETABULAR IMPINGEMENT; JOINT RANGE; AGREEMENT; KNEE;
D O I
10.3390/s22218154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient's device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. Methods: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory's 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. Results: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63-0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85-0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36-0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87-0.95 for the hip rotation range. Conclusions: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A Novel Smartphone App for the Measurement of Ultra-Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study
    Chen, Yung-Sheng
    Lu, Wan-An
    Pagaduan, Jeffrey C.
    Kuo, Cheng-Deng
    JMIR MHEALTH AND UHEALTH, 2020, 8 (07):
  • [42] Photo-Based Range-of-Motion Measurement: Reliability and Concurrent Validity in Children With Cerebral Palsy
    Johansen, Mette
    Haslund-Thomsen, Helle
    Kristensen, Jeanette
    Skou, Soren Thorgaard
    PEDIATRIC PHYSICAL THERAPY, 2020, 32 (02) : 151 - 160
  • [43] Reliability and validity of pose estimation algorithm for measurement of knee range of motion after total knee arthroplasty
    Saiki, Y.
    Kabata, T.
    Ojima, T.
    Kajino, Y.
    Kubo, N.
    Tsuchiya, H.
    BONE & JOINT RESEARCH, 2023, 12 (05): : 313 - 320
  • [44] Reliability and concurrent validity of a mobile application to measure thoracolumbar range of motion in low back pain patients
    Macedo, Liane de Brito
    Borges, Daniel Tezoni
    Melo, Samara Alencar
    Aires da Costa, Karinna Sonalya
    Sousa, Catarina de Oliveira
    Brasileiro, Jamilson Simoes
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2020, 33 (01) : 145 - 151
  • [45] Reliability, Concurrent Validity, and Minimal Detectable Change for iPhone Goniometer App in Assessing Knee Range of Motion
    Mehta, Saurabh P.
    Barker, Katherine
    Bowman, Brett
    Galloway, Heather
    Oliashirazi, Nicole
    Oliashirazi, Ali
    JOURNAL OF KNEE SURGERY, 2017, 30 (06) : 577 - 584
  • [46] Reliability and validity of a smartphone-based assessment of gait parameters across walking speed and smartphone locations: Body, bag, belt, hand, and pocket
    Silsupadol, Patima
    Teja, Kunlanan
    Lugade, Vipul
    GAIT & POSTURE, 2017, 58 : 516 - 522
  • [47] Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
    Quek, June
    Brauer, Sandra G.
    Treleaven, Julia
    Pua, Yong-Hao
    Mentiplay, Benjamin
    Clark, Ross Allan
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [48] A new iPhone application for measuring active craniocervical range of motion in patients with non-specific neck pain: a reliability and validity study
    Pourahmadi, Mohammad Reza
    Bagheri, Rasool
    Taghipour, Morteza
    Takamjani, Ismail Ebrahimi
    Sarrafzadeh, Javad
    Mohseni-Bandpei, Mohammad Ali
    SPINE JOURNAL, 2018, 18 (03) : 447 - 457
  • [49] In vitro validation and reliability study of electromagnetic skin sensors for evaluation of end range of motion positions of the hip
    Audenaert, E. A.
    Vigneron, L.
    Van Hoof, T.
    D'Herde, K.
    van Maele, G.
    Oosterlinck, D.
    Pattyn, C.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (12) : 1405 - 1412
  • [50] A novel rapid measurement method of cervical sagittal parameters based on the integrated inclinometer of a smartphone: a validity and reliability study
    Huang, Tianji
    Zhang, Chunyang
    Han, Zhenghan
    Zhong, Weiyang
    Zhao, Zenghui
    Zhu, Yong
    Luo, Xiaoji
    Zhang, Jie
    ANNALS OF MEDICINE, 2023, 55 (02)