Validity and Reliability of a Novel Smartphone Tele-Assessment Solution for Quantifying Hip Range of Motion

被引:7
作者
Marshall, Charlotte J. [1 ]
El-Ansary, Doa [1 ,2 ]
Pranata, Adrian [1 ]
Ganderton, Charlotte [1 ]
O'Donnell, John [3 ]
Takla, Amir [3 ]
Tran, Phong [1 ,2 ,4 ]
Wickramasinghe, Nilmini [1 ]
Tirosh, Oren [1 ,4 ]
机构
[1] Swinburne Univ Technol, Sch Hlth Sci, Hawthorn, Vic 3122, Australia
[2] Univ Melbourne, Sch Med, Dept Surg, Parkville, Vic 3052, Australia
[3] Hip Arthroscopy Australia, Richmond, Vic 3121, Australia
[4] Footscray Hosp, Dept Orthopaed Surg, Western Hlth, Footscray, Vic 3011, Australia
关键词
tele-assessment; smartphone; hip range of motion; FEMOROACETABULAR IMPINGEMENT; JOINT RANGE; AGREEMENT; KNEE;
D O I
10.3390/s22218154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient's device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. Methods: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory's 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. Results: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63-0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85-0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36-0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87-0.95 for the hip rotation range. Conclusions: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Hip internal and external rotation range of motion reliability in youth baseball players
    Bullock, Garrett S.
    Beck, Edward C.
    Collins, Gary S.
    Filbay, Stephanie R.
    Nicholson, Kristen F.
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2021, 61 (01) : 75 - 79
  • [32] Reliability and validity of a smartphone pulse rate application for the assessment of resting and elevated pulse rate
    Mitchell, Katy
    Graff, Megan
    Hedt, Corbin
    Simmons, James
    PHYSIOTHERAPY THEORY AND PRACTICE, 2016, 32 (06) : 494 - 499
  • [33] Reliability of hip internal rotation range of motion measurement using a digital inclinometer
    David A. Krause
    John H. Hollman
    Aaron J. Krych
    Michael M. Kalisvaart
    Bruce A. Levy
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 2562 - 2567
  • [34] The Intra- and Inter-Rater Reliability of a Hip Rotation Range-of-Motion Measurement Using a Smartphone Application in Academy Football (Soccer) Players
    Spork, Paul
    O'Brien, James
    Sepoetro, Morris
    Plachel, Maximilian
    Stoeggl, Thomas
    SPORTS, 2021, 9 (11)
  • [35] A Smartphone-Based Timed Up and Go Test Self-Assessment for Older Adults: Validity and Reliability Study
    Boettinger, Melissa Johanna
    Mellone, Sabato
    Klenk, Jochen
    Jansen, Carl-Philipp
    Stefanakis, Marios
    Litz, Elena
    Bredenbrock, Anastasia
    Fischer, Jan-Philipp
    Bauer, Juergen M.
    Becker, Clemens
    Gordt-Oesterwind, Katharina
    JMIR AGING, 2025, 8
  • [36] The concurrent validity and reliability of virtual reality to measure shoulder flexion and scaption range of motion
    Dejaco, Beate
    de Jong, Lex D.
    van Goor, Harry
    Staal, J. Bart
    Stolwijk, Niki
    Lewis, Jeremy
    PHYSIOTHERAPY, 2023, 120 : 95 - 102
  • [37] Reliability of tele-assessment of five repetition sit to stand and timed up and go tests in patients with non-specific chronic low back pain
    Ismail Ozsoy
    Ahmet Lutfi Uz
    Discover Health Systems, 3 (1):
  • [38] Reliability and validity of an iPhone® application for the measurement of lumbar spine flexion and extension range of motion
    Pourahmadi, Mohammad Reza
    Taghipour, Morteza
    Jannati, Elham
    Mohseni-Bandpei, Mohammad Ali
    Takamjani, Ismail Ebrahimi
    Rajabzadeh, Fatemeh
    PEERJ, 2016, 4
  • [39] Reliability and Agreement of Hip Range of Motion and Provocative Physical Examination Tests in Asymptomatic Volunteers
    Prather, Heidi
    Harris-Hayes, Marcie
    Hunt, Devyani M.
    Steger-May, Karen
    Mathew, Vinta
    Clohisy, John C.
    PM&R, 2010, 2 (10) : 888 - 895
  • [40] Validity of Markerless Motion Capture System and Its Correlation with Physical Characteristics for Hip Range of Motion Measurement: A Pilot Study
    Bak, Se-Young
    Ahn, Junghoon
    Choi, Hongtaek
    Lee, Seunghee
    Lim, Wootaek
    Kim, Hyeong-Dong
    SENSORS AND MATERIALS, 2025, 37 (03) : 965 - 976