Validity and Reliability of a Novel Smartphone Tele-Assessment Solution for Quantifying Hip Range of Motion

被引:7
作者
Marshall, Charlotte J. [1 ]
El-Ansary, Doa [1 ,2 ]
Pranata, Adrian [1 ]
Ganderton, Charlotte [1 ]
O'Donnell, John [3 ]
Takla, Amir [3 ]
Tran, Phong [1 ,2 ,4 ]
Wickramasinghe, Nilmini [1 ]
Tirosh, Oren [1 ,4 ]
机构
[1] Swinburne Univ Technol, Sch Hlth Sci, Hawthorn, Vic 3122, Australia
[2] Univ Melbourne, Sch Med, Dept Surg, Parkville, Vic 3052, Australia
[3] Hip Arthroscopy Australia, Richmond, Vic 3121, Australia
[4] Footscray Hosp, Dept Orthopaed Surg, Western Hlth, Footscray, Vic 3011, Australia
关键词
tele-assessment; smartphone; hip range of motion; FEMOROACETABULAR IMPINGEMENT; JOINT RANGE; AGREEMENT; KNEE;
D O I
10.3390/s22218154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient's device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. Methods: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory's 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. Results: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63-0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85-0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36-0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87-0.95 for the hip rotation range. Conclusions: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Reliability and validity of computer vision-based markerless human pose estimation for measuring hip and knee range of motion
    Hellsten, Thomas
    Arokoski, Jari
    Karlsson, Jonny
    Ristolainen, Leena
    Kettunen, Jyrki
    HEALTHCARE TECHNOLOGY LETTERS, 2025, 12 (01)
  • [22] Intra- and inter- rater reliability of the face-to-face assessment and tele-assessment of performance-based tests in older adults
    Ozsoy, Gulsah
    Aksoy, Kevser
    EUROPEAN GERIATRIC MEDICINE, 2024, 15 (03) : 601 - 607
  • [23] Reliability and validity of the Microgate Gyko for measuring range of motion of the low back
    Hamersma, Dave T.
    Hofste, Anke
    Rijken, Noortje H. M.
    Rohe, Moniek Roe of
    Oosterveld, Frits G. J.
    Soer, Remko
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2020, 45
  • [24] Accuracy and Reliability of Visual Inspection and Smartphone Applications for Measuring Finger Range of Motion
    Lee, Hannah H.
    St Louis, Kwesi
    Fowler, John R.
    ORTHOPEDICS, 2018, 41 (02) : E217 - E221
  • [25] Reliability of range of motion measurements obtained by goniometry, photogrammetry and smartphone applications in lower limb: A systematic review
    Canever, Jaquelini Betta
    Nonnenmacher, Carolina Holz
    Lima, Kelly Monica Marinho
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2025, 42 : 793 - 802
  • [26] A Smartphone-Centric System for the Range of Motion Assessment in Stroke Patients
    Lee, Wang Wei
    Yen, Shih-Cheng
    Tay, Arthur
    Zhao, Ziyi
    Xu, Tian Ma
    Ling, Karen Koh Mui
    Ng, Yee-Sien
    Chew, Effie
    Cheong, Angela Lou Kuen
    Huat, Gerald Koh Choon
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (06) : 1839 - 1847
  • [27] Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer
    Luedtke, Kerstin
    Schoettker-Koeniger, Thomas
    Hall, Toby
    Enns, Christine
    Grassold, Maike
    Hasselhoff-Styhler, Petra
    Neulinger, Christian
    Obrocki, Max
    Przyhoda, Philipp
    Schaefer, Axel
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [28] Validity and reliability of using photography for measuring knee range of motion: a methodological study
    Naylor, Justine M.
    Ko, Victoria
    Adie, Sam
    Gaskin, Clive
    Walker, Richard
    Harris, Ian A.
    Mittal, Rajat
    BMC MUSCULOSKELETAL DISORDERS, 2011, 12
  • [29] Validity and reliability of a smartphone motion analysis app for lower limb kinematics during treadmill running
    Mousavi, Seyed Hamed
    Hijmans, Juha M.
    Moeini, Forough
    Rajabi, Reza
    Ferber, Reed
    van der Worp, Henk
    Zwerver, Johannes
    PHYSICAL THERAPY IN SPORT, 2020, 43 : 27 - 35
  • [30] Reliability of hip internal rotation range of motion measurement using a digital inclinometer
    Krause, David A.
    Hollman, John H.
    Krych, Aaron J.
    Kalisvaart, Michael M.
    Levy, Bruce A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (09) : 2562 - 2567