Non-enhanced, ECG-gated MR angiography of the pedal vasculature: comparison with contrast-enhanced MR angiography and digital subtraction angiography in peripheral arterial occlusive disease

被引:15
作者
Schubert, Tilman [1 ,7 ]
Takes, Martin [1 ]
Aschwanden, Markus [2 ]
Klarhoefer, Markus [3 ]
Haas, Tanja [1 ]
Jacob, Augustinus L. [4 ]
Liu, David [5 ]
Gutzeit, Andreas [6 ]
Kos, Sebastian [6 ]
机构
[1] Univ Basel Hosp, Clin Radiol & Nucl Med, Basel, Switzerland
[2] Univ Basel Hosp, Dept Angiol, Basel, Switzerland
[3] Univ Basel Hosp, Clin Radiol & Nucl Med, Div Radiol Phys, Basel, Switzerland
[4] Radiol Clin Hirslanden, Zurich, Switzerland
[5] Univ British Columbia, Vancouver Gen Hosp, Dept Radiol, Vancouver, BC, Canada
[6] Hirslanden Clin St Anna, Dept Radiol & Nucl Med, Luzern, Switzerland
[7] Univ Wisconsin, Dept Radiol, 600 Highland Ave,E1-374, Madison, WI 53792 USA
关键词
Magnetic resonance angiography; Non-contrast; High resolution; Small vessel; Peripheral arterial occlusive disease; NEPHROGENIC SYSTEMIC FIBROSIS; SINGLE-SHOT MRA; RENAL-INSUFFICIENCY; MAGNETIC-RESONANCE; LOWER-EXTREMITIES; LIMB SALVAGE; T; EXPERIENCE; GADOLINIUM; MEDIA;
D O I
10.1007/s00330-015-4068-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was conducted in order to compare a high resolution, non-contrast-enhanced MRA (NATIVE SPACE, NE-MRA) of the pedal vasculature with contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). The prospective study consists of 20 PAOD patients. All patients underwent percutaneous transluminal angioplasty or stenting and received MR angiographies the following day. With CE-MRA, 75.7 % of vessel segments showed good, 16.4 % suboptimal and 7.9 % not usable image quality. With NE-MRA, 64.6 % showed good, 18.6 % suboptimal and 16.8 % not usable image quality. CE-MRA showed a sensitivity and negative predictive value of 90 %/95 % regarding significant stenosis (greater than 50 %), and specificity and positive predictive value were 88 %/77 %. Accordingly, sensitivity and negative predictive value for the NE-MRA were 96 %/97 % and specificity and positive predictive value were 80 %/69 % for stenoses greater than 50 %. The applied NE-MRA technique achieves high diagnostic accuracy even in very small distal arteries of the foot. However, the rate of non-diagnostic vessel segments is considerably higher for NE-MRA than for CE-MRA. NE-MRA is a valuable alternative to CE-MRA in selected patients. Comparison of non-enhanced MRA with contrast-enhanced MRA and DSA as gold standard. High resolution MRA at 3 T for the depiction of small pedal vessels. Evaluation of high resolution non-enhanced MRA in PAOD patients.
引用
收藏
页码:2705 / 2713
页数:9
相关论文
共 50 条
  • [41] Supra-aortic low-dose contrast-enhanced time-resolved magnetic resonance (MR) angiography at 3 T: comparison with time-of-flight MR angiography and high-resolution contrast-enhanced MR angiography
    Lee, Youn-Joo
    Kim, Bum-soo
    Koo, Ja-Sung
    Kim, Bom-Yi
    Jang, Jinhee
    Choi, Hyun Seok
    Jung, So-Lyung
    Ahn, Kook-Jin
    [J]. ACTA RADIOLOGICA, 2015, 56 (06) : 673 - 680
  • [42] Comparison of contrast enhanced MR-angiography-MRI and digital subtraction angiography in the evaluation of pancreas and/or kidney transplantation patients: initial experience
    Boeve, WJ
    Kok, T
    Tegzess, AM
    van Son, WJ
    Ploeg, RJ
    Sluiter, WJ
    Kamman, RL
    [J]. MAGNETIC RESONANCE IMAGING, 2001, 19 (05) : 595 - 607
  • [43] Subtraction MR Venography Acquired from Time-Resolved Contrast-Enhanced MR Angiography: Comparison with Phase-Contrast MR Venography and Single-Phase Contrast-Enhanced MR Venography
    Jang, Jinhee
    Kim, Bum-Soo
    Sung, Jinkyeong
    Kim, Bom-Yi
    Choi, Hyun Seok
    Jung, So-Lyung
    Ahn, Kook-Jin
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1353 - 1363
  • [45] Detection of Infragenual Arterial Disease Using Non-Contrast-Enhanced MR Angiography in Patients With Diabetes
    Liu, Xin
    Zhang, Na
    Fan, Zhaoyang
    Feng, Fei
    Yang, Qi
    Zheng, Hairong
    Liu, Pengcheng
    Li, Debiao
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (06) : 1422 - 1429
  • [46] Contrast-enhanced MR angiography in patients after kidney transplantation
    Huber, A
    Heuck, A
    Scheidler, J
    Holzknecht, N
    Baur, A
    Stangl, M
    Theodorakis, J
    Illner, WD
    Land, W
    Reiser, M
    [J]. EUROPEAN RADIOLOGY, 2001, 11 (12) : 2488 - 2495
  • [47] Non-enhanced and Non-gated MR Angiography for Robust Visualization of Peripheral Arteries Using Enhanced Acceleration-selective Arterial Spin Labeling (eAccASL)
    Shibukawa, Shuhei
    Konta, Natsuo
    Niwa, Tetsu
    Obara, Makoto
    Akamine, Yuta
    Shinozaki, Norihiko
    Okazaki, Takashi
    Nagafuji, Yui
    Miyati, Tosiaki
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (03) : 312 - 319
  • [48] Contrast-Enhanced MR Angiography of Cavopulmonary Connections in Adult Patients With Congenital Heart Disease
    Wagner, Moritz
    Kim-Lien Nguyen
    Khan, Sarah
    Mirsadraee, Saeed
    Satou, Gary M.
    Aboulhosn, Jamil
    Finn, J. Paul
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : W565 - W574
  • [49] Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases
    Krishnam, Mayil S.
    Tomasian, Anderanik
    Malik, Sachin
    Desphande, Vibhas
    Laub, Gerhard
    Ruehm, Stefan G.
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (06) : 1311 - 1320
  • [50] Peripheral Vasculature: High-Temporal- and High-Spatial-Resolution Three-dimensional Contrast-enhanced MR Angiography
    Haider, Clifton R.
    Glockner, James F.
    Stanson, Anthony W.
    Riederer, Stephen J.
    [J]. RADIOLOGY, 2009, 253 (03) : 831 - 843