PURPOSE: To assess the accuracy of 3 corneal horizontal meridian marking techniques using the iTrace Surgical Workstation in preoperative assessment for toric intraocular lens (IOL) implantation. SETTING: Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea. DESIGN: Prospective comparative observational study. METHODS: Patients were allocated into 3 groups. Three techniques marking with a nonpendular marker with a surgeon's direct visualization, slitlamp-assisted marking with a pendulum-attached marker, and slitlamp-assisted marking with a horizontal slit beam were used to perform the horizontal meridian marking. The marks were immediately documented and aligned with the Zaldivar toric caliper transparent topographic map. Using a horizontal reference meridian determined by the toric caliper, the accuracy of corneal horizontal marking techniques was quantitatively evaluated by determining the rotational deviation and vertical misalignment. RESULTS: For rotational deviation, the pendular marking showed the fewest errors to the horizontal reference meridian (mean error -0.66 degrees; mean absolute error [MAE] 3.77 degrees). There was a significant difference between the pendular marking and the surgeon's direct visual marking. For the MAE, the pendular marking showed less deviation than the surgeon's direct visual marking and the horizontal slit-beam marking. With vertical misalignment, there was no significant difference between the 3 different corneal horizontal meridian marking techniques. CONCLUSION: The slitlamp-assisted technique with the pendulum-attached marker was more precise than marking with a nonpendular marker with a surgeon's direct visualization and marking with a horizontal slit beam in preoperative assessment for toric IOLs. (C) 2015 ASCRS and ESCRS
引用
收藏
页码:1232 / 1240
页数:9
相关论文
共 28 条
  • [1] Astigmatism management in cataract surgery with the AcrySof toric intraocular lens
    Bauer, Noel J. C.
    de Vries, Niels E.
    Webers, Carroll A. B.
    Hendrikse, Fred
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) : 1483 - 1488
  • [2] Limbal relaxing incisions for primary mixed astigmatism and mixed astigmatism after cataract surgery
    Bayramlar, H
    Daglioglu, MC
    Borazan, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) : 723 - 728
  • [3] Carvalho MJ, 2007, J REFRACT SURG, V23, P499
  • [4] New Axis-marking Method for a Toric Intraocular Lens: Mapping Method
    Cha, Deoksun
    Kang, Su Yeon
    Kim, Seung-Hyun
    Song, Jong-Suk
    Kim, Hyo-Myung
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (05) : 375 - 379
  • [5] Prevalence of corneal astigmatism before cataract surgery
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    Peixoto-de-Matos, Sofia C.
    Gonzalez-Meijome, Jose M.
    Cervino, Alejandro
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) : 70 - 75
  • [6] Limbal relaxing incision during cataract extraction versus photoastigmatic keratectomy after cataract extraction in controlling pre-existing corneal astigmatism
    Fouda, Sameh
    Kamiya, Kazutaka
    Aizawa, Daisuke
    Shimizu, Kimiya
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (07) : 1029 - 1035
  • [7] Postoperative corneal shape changes: Microincision versus small-incision coaxial cataract surgery
    Hayashi, Ken
    Yoshida, Motoaki
    Hayashi, Hideyuki
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) : 233 - 239
  • [8] BIOMETRY OF 7,500 CATARACTOUS EYES
    HOFFER, KJ
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1980, 90 (03) : 360 - 368
  • [9] Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyes
    Hoffmann, Peter Christian
    Huetz, Werner W.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) : 1479 - 1485
  • [10] Clinical Evaluation of Accuracy of Horizontal Meridian Limbal Marking
    Igarashi, Akihito
    Kamiya, Kazutaka
    Shimizu, Kimiya
    [J]. OPTOMETRY AND VISION SCIENCE, 2013, 90 (06) : 540 - 545