Non-invasive characterization of coronary artery atherosclerotic plaque using dual energy CT: Explanation in ex-vivo samples

被引:14
作者
Mandal, Susama Rani [1 ]
Bharati, Avinav [1 ]
Haghighi, Rezvan Ravanfar [2 ]
Arava, Sudhir [3 ]
Ray, Ruma [3 ]
Jagia, Priya [4 ]
Sharma, Sanjiv [4 ]
Chatterjee, Sabyasachi [5 ]
Tabin, Millo [6 ]
Sharma, Munish [6 ]
Sharma, Sanjay [7 ]
Kumar, Pratik [1 ]
机构
[1] AIIMS, Dr BRA Inst Rotary Canc Hosp IRCH, Med Phys Unit, New Delhi 110029, India
[2] Shiraz Univ Med Sci, Med Imaging Res Ctr, Shiraz, Iran
[3] AIIMS, Dept Cardiac Pathol, New Delhi 110029, India
[4] AIIMS, Dept Cardiac Radiol, New Delhi 110029, India
[5] BGVS, Chem Engn Bldg Old,Indian Inst Sci Campus, Bangalore 560012, Karnataka, India
[6] AIIMS, Dept Forens Med, New Delhi 110029, India
[7] AIIMS, Dept Radiol, New Delhi 110029, India
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 45卷
关键词
Non-invasive; Dual energy CT; Atherosclerosis; Compositional analysis; 64-SLICE COMPUTED-TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; NUMBERS;
D O I
10.1016/j.ejmp.2017.12.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this study non-calcified plaque composition is evaluated by Dual Energy CT (DECT). Energy Dispersive X-ray Spectroscopy (EDS) has been used to study the Plaque composition. An attempt has been made to explain the DECT results with EDS analysis.& para;& para;Methods: Thirty-two ex-vivo human cadaver coronary artery samples were scanned by DECT and data was evaluated to calculate their effective atomic number and electron density (Z(eff) & rho(e) ) by inversion method. Result of DECT was compared with pathology to assess their differentiating capability. The EDS study was used to explain DECT outcome.& para;& para;Results: DECT study was able to differentiate vulnerable plaque from stable with 87% accuracy (area under the curve (AUC):0.85 [95% confidence interval {CI}:0.73-0.98}] and Kappa Coefficient (KC):0.75 with respect to pathology. EDS revealed significant compositional difference in vulnerable and stable plaque at p < .05. The weight percentage of higher atomic number elements like F, Na, Mg, S, Si, P, Cl, K and Ca was found to be slightly more in vulnerable plaques as compared to a stable plaque. EDS also revealed a significantly increased weight percentage of nitrogen in stable plaques.& para;& para;Conclusions: The EDS results were able to explain the outcomes of DECT study. This study conclusively explains the physics of DECT as a tool to assess the nature of non-calcified plaques as vulnerable and stable. The method proposed in this study allows for differentiation between vulnerable and stable plaque using DECT.
引用
收藏
页码:52 / 58
页数:7
相关论文
共 46 条
  • [41] Dual-layer spectral detector CT: non-inferiority assessment compared to dual-source dual-energy CT in discriminating uric acid from non-uric acid renal stones ex vivo
    Lakshmi Ananthakrishnan
    Xinhui Duan
    Yin Xi
    Matthew A. Lewis
    Margaret S. Pearle
    Jodi A. Antonelli
    Harold Goerne
    Elysha M. Kolitz
    Suhny Abbara
    Robert E. Lenkinski
    Julia R. Fielding
    John R. Leyendecker
    [J]. Abdominal Radiology, 2018, 43 : 3075 - 3081
  • [42] Dual-layer spectral detector CT: non-inferiority assessment compared to dual-source dual-energy CT in discriminating uric acid from non-uric acid renal stones ex vivo
    Ananthakrishnan, Lakshmi
    Duan, Xinhui
    Xi, Yin
    Lewis, Matthew A.
    Pearle, Margaret S.
    Antonelli, Jodi A.
    Goerne, Harold
    Kolitz, Elysha M.
    Abbara, Suhny
    Lenkinski, Robert E.
    Fielding, Julia R.
    Leyendecker, John R.
    [J]. ABDOMINAL RADIOLOGY, 2018, 43 (11) : 3075 - 3081
  • [43] Diagnostic Performance of Coronary CT Angiography, Stress Dual-Energy CT Perfusion, and Stress Perfusion Single-Photon Emission Computed Tomography for Coronary Artery Disease: Comparison with Combined Invasive Coronary Angiography and Stress Perfusion Cardiac MRI
    Chung, Hyun Woo
    Ko, Sung Min
    Hwang, Hweung Kon
    So, Young
    Yi, Jeong Geun
    Lee, Eun Jeong
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (03) : 476 - 486
  • [44] Non-invasive detection of coronary inflammation using computed tomography and prediction of residual cardiovascular risk (the CRISP CT study): a post-hoc analysis of prospective outcome
    Oikonomou, Evangelos K.
    Marwan, Mohamed
    Desai, Milind Y.
    Mancio, Jennifer
    Alashi, Alaa
    Centeno, Erika Hutt
    Thomas, Sheena
    Herdman, Laura
    Kotanidis, Christos P.
    Thomas, Katharine E.
    Griffin, Brian P.
    Flamm, Scott D.
    Antonopoulos, Alexios S.
    Shirodaria, Cheerag
    Sabharwal, Nikant
    Deanfield, John
    Neubauer, Stefan
    Hopewell, Jemma C.
    Channon, Keith M.
    Achenbach, Stephan
    Antoniades, Charalambos
    [J]. LANCET, 2018, 392 (10151) : 929 - 939
  • [45] Quantitative Analysis of Coronary Plaque Composition by Dual-Source CT in Patients with Acute Non-ST-Elevation Myocardial Infarction Compared to Patients with Stable Coronary Artery Disease Correlated with Virtual Histology Intravascular Ultrasound
    Sudarski, Sonja
    Fink, Christian
    Sueselbeck, Tim
    Kayed, Hany
    Schoenberg, Stefan O.
    Borggrefe, Martin
    Vliegenthart, Rozemarijn
    Oudkerk, Matthijs
    Henzler, Thomas
    [J]. ACADEMIC RADIOLOGY, 2013, 20 (08) : 995 - 1003
  • [46] Myocardial extracellular volume fraction quantitation using cardiac dual-energy CT with late iodine enhancement in patients with heart failure without coronary artery disease: A single-center prospective study
    Qi, Rong-Xing
    Shao, Jun
    Jiang, Jia-Shen
    Ruan, Xi-Wu
    Huang, Sheng
    Zhang, Qing
    Hu, Chun-Hong
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 140