Automatic Determination of Vertical Cup-to-Disc Ratio in Retinal Fundus Images for Glaucoma Screening

被引:24
作者
Guo, Jiapan [1 ]
Azzopardi, George [1 ]
Shi, Chenyu [1 ]
Jansonius, Nomdo M. [2 ]
Petkov, Nicolai [1 ]
机构
[1] Univ Groningen, Bernoulli Inst Math Comp Sci & Artificial Intelli, NL-9747 AG Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Ophthalmol, NL-9713 GW Groningen, Netherlands
来源
IEEE ACCESS | 2019年 / 7卷
关键词
Glaucoma; retinal fundus images; vertical cup-to-disk ratio; trainable COSFIRE filters; GMLVQ; OPTIC-NERVE HEAD; TRAINABLE COSFIRE FILTERS; VESSEL DELINEATION; BLOOD-VESSELS; SEGMENTATION; LOCALIZATION; PREVALENCE; CLASSIFICATION; IDENTIFICATION; RECOGNITION;
D O I
10.1109/ACCESS.2018.2890544
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Glaucoma is a chronic progressive optic neuropathy that causes visual impairment or blindness if left untreated. It is crucial to diagnose it at an early stage in order to enable treatment. Fundus photography is a viable option for population-based screening. A fundus photograph enables the observation of the excavation of the optic disk-the hallmark of glaucoma. The excavation is quantified as a vertical cup-to-disk ratio (VCDR). The manual assessment of retinal fundus images is, however, time-consuming and costly. Thus, an automated system is necessary to assist human observers. We propose a computer-aided diagnosis system, which consists of the localization of the optic disk, the determination of the height of the optic disk and the cup, and the computation of the VCDR. We evaluated the performance of our approach on eight publicly available datasets, which have, in total, 1712 retinal fundus images. We compared the obtained VCDR values with those provided by an experienced ophthalmologist and achieved a weighted VCDR mean difference of 0.11. The system provides a reliable estimation of the height of the optic disk and the cup in terms of the relative height error (RHE = 0.08 and 0.09, respectively). The Bland-Altman analysis showed that the system achieves a good agreement with the manual annotations, especially for large VCDRs which indicate pathology.
引用
收藏
页码:8527 / 8541
页数:15
相关论文
共 75 条
  • [21] Guo J., 2015, P 8 GI C AUT SYST, V842, P70
  • [22] Inhibition-augmented trainable COSFIRE filters for keypoint detection and object recognition
    Guo, Jiapan
    Shi, Chenyu
    Azzopardi, George
    Petkov, Nicolai
    [J]. MACHINE VISION AND APPLICATIONS, 2016, 27 (08) : 1197 - 1211
  • [23] Recognition of Architectural and Electrical Symbols by COSFIRE Filters with Inhibition
    Guo, Jiapan
    Shi, Chenyu
    Azzopardi, George
    Petkov, Nicolai
    [J]. COMPUTER ANALYSIS OF IMAGES AND PATTERNS, CAIP 2015, PT II, 2015, 9257 : 348 - 358
  • [24] Hohn U., 2015, PLOS ONE, V10, P1
  • [25] Locating the optic nerve in a retinal image using the fuzzy convergence of the blood vessels
    Hoover, A
    Goldbaum, M
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (08) : 951 - 958
  • [26] The Rotterdam Study: 2018 update on objectives, design and main results
    Ikram, M. Arfan
    Brusselle, Guy G. O.
    Murad, Sarwa Darwish
    van Duijn, Cornelia M.
    Franco, Oscar H.
    Goedegebure, Andr
    Klaver, Caroline C. W.
    Nijsten, Tamar E. C.
    Peeters, Robin P.
    Stricker, Bruno H.
    Tiemeier, Henning
    Uitterlinden, Andre G.
    Vernooij, Meike W.
    Hofman, Albert
    [J]. EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2017, 32 (09) : 807 - 850
  • [27] Ophthalmoscopic evaluation of the optic nerve head
    Jonas, JB
    Budde, WM
    Panda-Jonas, S
    [J]. SURVEY OF OPHTHALMOLOGY, 1999, 43 (04) : 293 - 320
  • [28] Kauppi T., 2007, P 11 C MED IM UND AN
  • [29] Detection of Glaucoma Using Cup to Disc Ratio From Spectra lDomain Optical Coherence Tomography Images
    Khalil, Tehmina
    Akram, M. Usman
    Raja, Hina
    Jameel, Amina
    Basit, Imran
    [J]. IEEE ACCESS, 2018, 6 : 4560 - 4576
  • [30] Khawaja AP, 2013, BMJ OPEN, P3