Optimal combination of electrodes and conductive gels for brain electrical impedance tomography

被引:13
|
作者
Yang, Lin [1 ]
Li, Heng [2 ]
Ding, Junjie [3 ]
Li, Weichen [2 ]
Dong, Xiuzhen [2 ]
Wen, Zhihong [1 ]
Shi, Xuetao [2 ]
机构
[1] Fourth Mil Med Univ, Dept Aerosp Med, Xian, Shaanxi, Peoples R China
[2] Fourth Mil Med Univ, Dept Biomed Engn, Xian, Shaanxi, Peoples R China
[3] Fourth Mil Med Univ, Sch Preclin Med, Xian, Shaanxi, Peoples R China
来源
BIOMEDICAL ENGINEERING ONLINE | 2018年 / 17卷
基金
中国国家自然科学基金;
关键词
Brain EIT; Electrode; Conductive gel; Combination; SKIN-CONDUCTANCE; STROKE; HEAD; EIT; MODEL; HZ;
D O I
10.1186/s12938-018-0617-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundElectrical impedance tomography (EIT) is an emerging imaging technology that has been used to monitor brain injury and detect acute stroke. The time and frequency properties of electrode-skin contact impedance are important for brain EIT because brain EIT measurement is performed over a long period when used to monitor brain injury, and is carried out across a wide range of frequencies when used to detect stroke. To our knowledge, no study has simultaneously investigated the time and frequency properties of both electrode and conductive gel for brain EIT.MethodsIn this study, the contact impedance of 16 combinations consisting of 4 kinds of clinical electrode and five types of commonly used conductive gel was measured on ten volunteers' scalp for a period of 1h at frequencies from 100Hz to 1MHz using the two-electrode method. And then the performance of each combination was systematically evaluated in terms of the magnitude of contact impedance, and changes in contact impedance with time and frequency.ResultsResults showed that combination of Ag+/Ag+Cl- powder electrode and low viscosity conductive gel performed best overall (Ten 20((R)) in this study); it had a relatively low magnitude of contact impedance and superior performance regarding contact impedance with time (p<0.05) and frequency (p<0.05).ConclusionsExperimental results indicates that the combination of Ag+/Ag+Cl- powder electrode and low viscosity conductive gel may be the best choice for brain EIT.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Optimal combination of electrodes and conductive gels for brain electrical impedance tomography
    Lin Yang
    Heng Li
    Junjie Ding
    Weichen Li
    Xiuzhen Dong
    Zhihong Wen
    Xuetao Shi
    BioMedical Engineering OnLine, 17
  • [2] Optimal design of electrodes for an electrical impedance tomography based flexible sensor
    Li, Rui
    Hao, Zhiliang
    Mu, Wenjun
    Wang, Xiaojie
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2019, 2019, 10970
  • [3] ELECTRICAL IMPEDANCE TOMOGRAPHY WITH POINT ELECTRODES
    Delbary, Fabrice
    Kress, Rainer
    JOURNAL OF INTEGRAL EQUATIONS AND APPLICATIONS, 2010, 22 (02) : 193 - 216
  • [4] A RECONSTRUCTION ALGORITHM OF ELECTRICAL-IMPEDANCE TOMOGRAPHY WITH OPTIMAL CONFIGURATION OF THE DRIVEN ELECTRODES
    KYRIACOU, GA
    KOUKOURLIS, CS
    SAHALOS, JN
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (03) : 430 - 438
  • [5] Design of electrodes and current limits for low frequency electrical impedance tomography of the brain
    Gilad, O.
    Horesh, L.
    Holder, D. S.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (07) : 621 - 633
  • [6] Design of electrodes and current limits for low frequency electrical impedance tomography of the brain
    O. Gilad
    L. Horesh
    D. S. Holder
    Medical & Biological Engineering & Computing, 2007, 45 : 621 - 633
  • [7] OPTIMAL TRANSPORTATION FOR ELECTRICAL IMPEDANCE TOMOGRAPHY
    Bao, Gang
    Zhang, Yixuan
    MATHEMATICS OF COMPUTATION, 2024, 93 (349) : 2361 - 2389
  • [8] Frequency marked electrodes in electrical impedance tomography
    Granot, Y.
    Rubinsky, B.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 380 - 383
  • [9] Current injection electrodes for electrical impedance tomography
    Armstrong, S
    Jennings, D
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (04) : 797 - 802
  • [10] OPTIMAL ELECTROLYTIC CHLORIDING OF SILVER INK ELECTRODES FOR USE IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    MCADAMS, ET
    HENRY, P
    MCCANDERSON, J
    JOSSINET, J
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 19 - 23