Collaborative validation of the quantification method for suspected allergens and test of an automated data treatment

被引:20
作者
Chaintreau, Alain
Cicchetti, Esmeralda
David, Nathalie [1 ]
Earls, Andy [2 ]
Gimeno, Pascal [3 ]
Grimaud, Beatrice [4 ]
Joulain, Daniel [5 ]
Kupfermann, Nikolai [6 ]
Kuropka, Gryta [7 ]
Saltron, Frederic [8 ]
Schippa, Christine [9 ]
机构
[1] Chanel, F-92521 Neuilly Sur Seine, France
[2] LGC Ltd, Teddington TW11 0LY, Middx, England
[3] AFSSAPS, F-34740 Vendargues, France
[4] Yves Rocher, F-92444 Issy Les Moulineaux, France
[5] PRODAROM, F-06131 Grasse, France
[6] Eurofins Consumer Prod Testing GmbH, D-22761 Hamburg, Germany
[7] TUV Rheinland LGA Prod GmbH, D-51105 Cologne, Germany
[8] SCL DGCCRF DGDDI, F-13388 Marseille 13, France
[9] V MANE FILS, F-06620 Le Bar Sur Loup, France
关键词
Quantification; Fragrance; Allergen; Validation; Accuracy profile; GC/MS; 2-DIMENSIONAL GAS-CHROMATOGRAPHY; QUADRUPOLE MASS-SPECTROMETRY; FRAGRANCE ALLERGENS; QUANTITATIVE-ANALYSIS;
D O I
10.1016/j.chroma.2011.08.072
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Previous publications investigated different data treatment strategies for quantification of volatile suspected allergens by GC/MS. This publication presents the validation results obtained on "ready to inject" samples under reproducibility conditions following inter-laboratory ring-testing. The approach is based on the monitoring of three selected ions per analyte using two different GC capillary columns. To aid the analysts a decisional tree is used for guidance during the interpretation of the analytical results. The method is evaluated using a fragrance oil concentrate spiked with all suspected allergens to mimic the difficulty of a real sample extract or perfume oil. At the concentrations of 10 and 100 mg/kg, imposed by Directive 76/768/EEC for labeling of leave-on and rinse-off cosmetics, the mean bias is +14% and -4%, respectively. The method is linear for all analytes, and the prediction intervals for each analyte have been determined. To speed up the analyst's task, an automated data treatment is also proposed. The method mean bias is slightly shifted towards negative values. but the method prediction intervals are close to that resulting from the decisional tree. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:7869 / 7877
页数:9
相关论文
共 21 条
[1]  
[Anonymous], 2005, Validation of analytical procedures: Text and methodology Q2 (R1)
[2]  
[Anonymous], 2002, Off. J. Eur. Comm, VL221, P8
[3]  
[Anonymous], OFF J EUR COMMUN
[4]  
[Anonymous], 2003, PERFUM FLAVORIST
[5]  
[Anonymous], SPECTRA ANAL
[6]  
[Anonymous], ZHONGGUO WEISHENG JI
[7]   GC-MS quantification of suspected volatile allergens in fragrances. 2. Data treatment strategies and method performances [J].
Bassereau, Maud ;
Chaintreau, Alain ;
Duperrex, Stephanie ;
Joulain, Daniel ;
Leijs, Hans ;
Loesing, Gerd ;
Owen, Neil ;
Sherlock, Alan ;
Schippa, Christine ;
Thorel, Pierre-Jean ;
Vey, Matthias .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (01) :25-31
[8]   GC-MS quantitation of fragrance compounds suspected to cause skin reactions. 1 [J].
Chaintreau, A ;
Joulain, D ;
Marin, C ;
Schmidt, CO ;
Vey, M .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (22) :6398-6403
[9]   Identification, quantitation and method validation for the analysis of suspected allergens in fragrances by comprehensive two-dimensional gas chromatography coupled with quadrupole mass spectrometry and with flame ionization detection [J].
Cordero, Chiara ;
Bicchi, Carlo ;
Joulain, Daniel ;
Rubiolo, Patrizia .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) :37-49
[10]   Determination of suspected allergens in non-volatile matrices using PTV injection with automated liner exchange and GC-MS [J].
David, Frank ;
Devos, Christophe ;
Joulain, Daniel ;
Chaintreau, Alain ;
Sandra, Pat .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (11) :1587-1594