Avoiding overvoltage problems in three-phase distributed-generation systems during unbalanced voltage sags

被引:5
作者
Castilla, Miguel [1 ]
Camacho, Antonio [2 ]
Miret, Jaume [1 ]
Guzman, Ramon [2 ]
Garcia de Vicuna, Luis [1 ]
机构
[1] Tech Univ Catalonia, Dept Elect Engn, Vilanova I La Geltru, Spain
[2] Tech Univ Catalonia, Automat Control Dept, Vilanova I La Geltru, Spain
关键词
distributed power generation; voltage control; power convertors; power generation control; power grids; power control; overvoltage; power supply quality; control scheme; overvoltage problems; flexible oscillating-power control; slope voltage control; good voltage regulation; voltage support characteristics; three-phase distributed-generation systems; unbalanced voltage sags; distributed generation systems; specific grid-code requirements; reactive current injection; ancillary service; unbalanced conditions; phase voltages; balanced reactive current; grid impedance; GRID-CONNECTED CONVERTERS; PEAK CURRENT LIMITATION; REACTIVE POWER-CONTROL; CONTROL STRATEGY; RIDE-THROUGH; ACTIVE POWER; INVERTERS; SUPPORT; OPERATION; PHASE;
D O I
10.1049/iet-pel.2019.1178
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
During voltage sags, distributed generation systems must fulfil specific grid-code requirements for reactive current injection. This ancillary service can produce overvoltage problems in networks operating in unbalanced conditions when the amplitude of one of the phase voltages is higher than the others and a balanced reactive current is injected through large grid impedance. This study proposes a control scheme to avoid these overvoltage problems, thus reducing the risk of cascade disconnection that this incident may produce. The derivation of the control scheme starts from the flexible oscillating-power control, introduces the necessary modifications so that this control meets the grid-code requirements for current injection and combines it with a slope voltage control to achieve a good voltage regulation. A theoretical analysis is included to determine the expressions that quantify the voltage support characteristics of the proposal. Finally, selected experimental results are reported to validate the characteristics of the proposed control.
引用
收藏
页码:1537 / 1545
页数:9
相关论文
共 35 条
  • [1] Overview of Recent Grid Codes for Wind Power Integration
    Altin, Muefit
    Goeksu, Oemer
    Teodorescu, Remus
    Rodriguez, Pedro
    Jensen, Birgitte-Bak
    Helle, Lars
    [J]. OPTIM 2010: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, PTS I-IV, 2010, : 1152 - +
  • [2] Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame
    Bojoi, RI
    Griva, G
    Bostan, V
    Guerriero, M
    Farina, F
    Profumo, F
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) : 1402 - 1412
  • [3] Active and Reactive Power Injection Strategies for Three-Phase Four-Wire Inverters During Symmetrical/Asymmetrical Voltage Sags
    Brandao, Danilo Iglesias
    Mendes, Frederico E. G.
    Ferreira, Reginaldo Vagner
    Silva, Sidelmo Magalhaes
    Pires, Igor Amariz
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (03) : 2347 - 2355
  • [4] Control Strategy for Distribution Generation Inverters to Maximize the Voltage Support in the Lowest Phase During Voltage Sags
    Camacho, Antonio
    Castilla, Miguel
    Miret, Jaume
    Garcia de Vicuna, Luis
    Garnica L, Miguel Andres
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (03) : 2346 - 2355
  • [5] Active and Reactive Power Strategies With Peak Current Limitation for Distributed Generation Inverters During Unbalanced Grid Faults
    Camacho, Antonio
    Castilla, Miguel
    Miret, Jaume
    Borrell, Angel
    Garcia de Vicuna, Luis
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) : 1515 - 1525
  • [6] A Low-Voltage Ride-Through Technique for Grid-Connected Converters With Reduced Power Transistors Stress
    Chen, Hsin-Chih
    Lee, Chia-Tse
    Cheng, Po-Tai
    Teodorescu, Remus
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (12) : 8562 - 8571
  • [7] European Network of Transmission System Operator (ENTSO), 2016, NETW COD REQ GRID CO
  • [8] Control Strategy for Grid-Connected Three-Phase Inverters During Voltage Sags to Meet Grid Codes and to Maximize Power Delivery Capability
    Garnica Lopez, Miguel Andres
    Luis Garcia de Vicuna, Jose
    Miret, Jaume
    Castilla, Miguel
    Guzman, Ramon
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (11) : 9360 - 9374
  • [9] Impact of wind power plant reactive current injection during asymmetrical grid faults
    Goksu, Omer
    Teodorescu, Remus
    Bak, Claus Leth
    Iov, Florin
    Kjaer, Philip Carne
    [J]. IET RENEWABLE POWER GENERATION, 2013, 7 (05) : 484 - 492
  • [10] Asymmetrical Grid Fault Ride-Through Strategy of Three-Phase Grid-Connected Inverter Considering Network Impedance Impact in Low-Voltage Grid
    Guo, Xiaoqiang
    Zhang, Xue
    Wang, Baocheng
    Wu, Weiyang
    Guerrero, Josep M.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1064 - 1068