Translation model for anterior segment tomographic data to corneal spherical aberration derived from a Monte-Carlo simulation based on raytracing

被引:0
|
作者
Langenbucher, Achim [1 ]
Szentmary, Nora [2 ,3 ]
Cayless, Alan [4 ]
Munninghoff, Lena [5 ]
Wortmann, Rosalie [5 ]
Wendelstein, Jascha [1 ,6 ]
Hoffmann, Peter [5 ]
机构
[1] Saarland Univ, Dept Expt Ophthalmol, Homburg, Germany
[2] Saarland Univ, Dr Rolf M Schwiete Ctr Limbal Stem Cell & Aniridi, Homburg, Germany
[3] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
[4] Open Univ, Sch Phys Sci, Milton Keynes, Bucks, England
[5] Augen & Laserklin Castrop Rauxel, Castrop Rauxel, Germany
[6] Johannes Kepler Univ Linz, Med Fac, Linz, Austria
关键词
cataract surgery; cornea asphericity; linear mixed-effects model; Monte-Carlo simulation; raytracing; spherical aberration; INTRAOCULAR-LENS; LIGHT REFLEX; IOL;
D O I
10.1111/aos.15125
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Intraocular lenses with a negative aspherical design for correction of corneal spherical aberration (SA) have gained popularity in recent decades. In most cases, a 'one size fits all' concept is followed, where all eyes receive lenses with the same SA correction. The purpose of this study is to develop a strategy based on raytracing using anterior segment tomography data to extract corneal SA and to provide simple multivariable linear models for prediction of corneal SA. Methods The analysis was based on a large dataset of 8737 measurements of 8737 eyes from 1 clinical centre, using the Casia2 anterior segment tomographer. An optical model based on: corneal front and back surface radius Ra and Rp, asphericities Qa and Qp, corneal thickness CCT, anterior chamber depth ACD, and pupil centre position (X-Y position: Pup(X) and Pup(Y)), was defined for each measurement. Corneal SA was derived using a 6-mm aperture perpendicular to the incident ray and centred on the chief ray, and linear prediction models were derived for SA using biometric data. Cross-validation was used for model performance evaluation. Results Using raytracing, the wavefront error within an aperture (6-mm diameter centred on the intersection of the chief ray with the cornea) was calculated and corneal SA was extracted. After identifying the relevant effect sizes (Ra, Qa, Rp Qp, ACD, Pup(X) and Pup(Y)) using stepwise linear regression, linear mixed-effects models (model 1: all effect sizes, model 2: Ra, Qa, Rp and Qp, model 3: Ra and Qa) were set up on the training data in terms of a Monte-Carlo simulation. On the test data (training data), model 1 with a mean absolute/root-mean-squared prediction error of 0.0095/0.0130 (0.0095/0.0127) performed similarly to model 2 with 0.0097/0.0131 (0.0096/0.0127), and both outperformed model3 with 0.0152/0.0197 (0.0148/0.0190). Conclusion Based on the Casia2 anterior segment tomographer, corneal SA could be derived using shape data (curvature and asphericities) of both corneal surfaces (model 2). This information could easily be used for selection of the appropriate negative aspherical lens design in cataract surgery.
引用
收藏
页码:E1665 / E1674
页数:10
相关论文
共 50 条
  • [31] Efficient GPU-based Monte-Carlo simulation of diffusion in real astrocytes reconstructed from confocal microscopy
    Nguyen, Khieu-Van
    Hernandez-Garzon, Edwin
    Valette, Julien
    JOURNAL OF MAGNETIC RESONANCE, 2018, 296 : 188 - 199
  • [32] Efficacy of quantifying marker-cluster rigidity in a multi-segment foot model: a Monte-Carlo based global sensitivity analysis and regression model
    Chan, Po-Hsiang
    Stebbins, Julie
    Zavatsky, Amy B.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (03) : 308 - 319
  • [33] Assessment of New Building Recognition Technique Based on Monte Carlo Simulation from LIDAR Data
    Elhifnawy, H.
    Elhabiby, M.
    El-Sheimy, N.
    2010 CANADIAN GEOMATICS CONFERENCE AND SYMPOSIUM OF COMMISSION I, ISPRS CONVERGENCE IN GEOMATICS - SHAPING CANADA'S COMPETITIVE LANDSCAPE, 2010, 38
  • [34] Probabilistic prediction of direct normal irradiance derived from global horizontal irradiance over the Korean Peninsula by using Monte-Carlo simulation
    Kim, Chang Ki
    Kim, Hyun-Goo
    Kang, Yong-Heack
    Yun, Chang-Yeol
    Kim, Shin Young
    SOLAR ENERGY, 2019, 180 : 63 - 74
  • [35] STUDY OF THE NEUTRON FIELD FROM A HADRONIC CASCADE IN IRON - VERIFICATION OF A MONTE-CARLO CALCULATIONAL MODEL BY COMPARISON WITH MEASURED DATA
    ZAZULA, JM
    TESCH, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (01): : 164 - 178
  • [36] Study of the Monte-Carlo model based on the measurement of irradiance distribution in myocardium from interventional devices in photodynamic therapy
    Matsuzaki, Ryota
    Yazima, Masahiro
    Ogawa, Emiyu
    Takahashi, Mei
    Arai, Tsunenori
    1600, Japan Soc. of Med. Electronics and Biol. Engineering (52)
  • [37] THE DOSE TO ORGANS AND TISSUES IN CHILDREN FROM EXTERNAL PHOTON EXPOSURES CALCULATED USING MONTE-CARLO METHODS AND COMPUTER TOMOGRAPHIC 3-DIMENSIONAL DATA
    SCHNEIDER, K
    FENDEL, H
    WILLIAMS, G
    ZANKL, M
    DREXLER, G
    PEDIATRIC RADIOLOGY, 1986, 16 (04) : 337 - 337
  • [38] Water quality assessment of east Tiaoxi River, China, based on a comprehensive water quality index model and Monte-Carlo simulation
    Jin, Wei
    Li, Yuan
    Lu, Li
    Zhang, Dong
    He, Shanying
    Shentu, Jiali
    Chai, Qiwei
    Huang, Lei
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [39] Water quality assessment of east Tiaoxi River, China, based on a comprehensive water quality index model and Monte-Carlo simulation
    Wei Jin
    Yuan Li
    Li Lu
    Dong Zhang
    Shanying He
    Jiali Shentu
    Qiwei Chai
    Lei Huang
    Scientific Reports, 12
  • [40] A method of learning implication networks from empirical data: Algorithms and Monte Carlo simulation based validation
    Liu, JM
    Desmarais, MC
    Tang, YY
    INFORMATION INTELLIGENCE AND SYSTEMS, VOLS 1-4, 1996, : 1291 - 1296